  1. Depends do you plan on leaving the windows open...

    Depends do you plan on leaving the windows open when you turn the system back on.
  2. Unfortunately no we don't

    Unfortunately no we don't
  3. $ to get rid of an aluminum or copper coil is odd...

    $ to get rid of an aluminum or copper coil is odd seein as it's worth money even as scrap.
  4. Replies
    13
    Views
    1,082

    Lol you called a tech or you had him come out and...

    Lol you called a tech or you had him come out and diagnose the bad motor. I would find that quite amusing if you got an over the phone diagnosis and the motor isnt actually bad
  5. Replies
    26
    Views
    2,638

    I know the vent trap must be there the drain on...

    I know the vent trap must be there the drain on the coupling is only there to drain the little bit that runs back along the pipe instead of dropping in the trap
  6. Replies
    26
    Views
    2,638

    The rubber coupling that attaches the vent pipe...

    The rubber coupling that attaches the vent pipe to inducer has a drain on it, if you look you can see the tube running from there to the internal trap of the furnace in the diagram

    And up here...
  7. Replies
    26
    Views
    2,638

    I'm familiar with the unit an what it calls for,...

    I'm familiar with the unit an what it calls for, with the sweep pointed up the exhaust has a natural upshot and the condensate for the most part due to gravity will fall straight down the pipe into...
  8. Replies
    26
    Views
    2,638

    Gravity takes care of the condensate an what...

    Gravity takes care of the condensate an what makes it back into the furnace the collector box deals with
  9. Replies
    26
    Views
    2,638

    That t is definitely upside down the sweep of the...

    That t is definitely upside down the sweep of the tee should be pointing up to accommodate the flow of the exhaust
  10. Replies
    10
    Views
    708

    Did either company actually pull the heat...

    Did either company actually pull the heat exchanger to be positive either way.
  11. Replies
    13
    Views
    854

    Wish we had castle law up here.

    Wish we had castle law up here.
  12. Replies
    46
    Views
    4,485

    I have a 2011 ram with cap and a roller bed gas...

    I have a 2011 ram with cap and a roller bed gas milage is great and I've never had a problem with it. Don't think I could go back to a van now after being spoiled with the 4x4
  13. Replies
    7
    Views
    623

    Air to air with electric backup something like a...

    Air to air with electric backup something like a Mitsubishi zuba
  14. For all we know it could've been so under fired...

    For all we know it could've been so under fired that it was useing less then the proper orfices
  15. No crack why'd they replace it and not just...

    No crack why'd they replace it and not just follow instructions for cleaning it
  16. Replies
    8
    Views
    443

    Why in the world did you go to all that trouble a...

    Why in the world did you go to all that trouble a pro would be able to set the fan with a thermostatic switch so it would come on when it's hot and shut off when cold. No need for plugging in and...
  17. Woseley always brings parts in for me

    Woseley always brings parts in for me
  18. Replies
    6
    Views
    451

    If you're going to call them to evac and recharge...

    If you're going to call them to evac and recharge you might as well let them deal with the leak as I doubt it will cost that much more
  19. Replies
    9
    Views
    548

    I might be inclined to disagree yes the gas side...

    I might be inclined to disagree yes the gas side of things you're only gonna get 6 or 7% more efficient but an ECM is going to improve the electrical efficiency and comfort
  20. The problem is places like hi mark putting out...

    The problem is places like hi mark putting out fully licensed fitters in six months that don't even know how to flare a piece of copper. When I did my 636 cert I would say 70% of the people there...
  21. The cert is stupid I'll agree but when tssa is...

    The cert is stupid I'll agree but when tssa is standing there wanting your certification for the vent pipe you're installing it'll be a lot cheaper to pull out your ticket
  22. Contact the manufacture or a wholesaler the one I...

    Contact the manufacture or a wholesaler the one I did was organized by woseley
  23. Replies
    16
    Views
    692

    -yes it will use electricity -nothing is free...

    -yes it will use electricity
    -nothing is free
    -it has it's own system for a reason
    -air exchanges in the space is a good thing
    -it will have a more balanced tempature and feel more comfortable
  24. Replies
    16
    Views
    692

    Leave the fan on on the upstairs unit

    Leave the fan on on the upstairs unit
  25. Replies
    3
    Views
    600

    I tired reading your post a couple times and I'm...

    I tired reading your post a couple times and I'm still not sure what the problem is. If you clean it up a bit someone might be able to better understand what the problem is.