05-18-2006, 08:40 PM
Thread: Electric Expansion Valve
by miller2000- Replies
- 8
- Views
- 1,626
Today was a good day sporlan final called and the...
Today was a good day sporlan final called and the parts are just being made available. They might be about three weeks out but at least they called and thanks for all the help guys
-
05-16-2006, 08:28 PM
Thread: Electric Expansion Valve
by miller2000- Replies
- 8
- Views
- 1,626
I have called the sales office every day and thay...
I have called the sales office every day and thay said that sporlan has not called them back I also used a differant distributerwith the same info and sporlan has not called them back the same as the...
-
05-16-2006, 10:33 AM
Thread: Electric Expansion Valve
by miller2000- Replies
- 8
- Views
- 1,626
I have but sporlan has not called anyone back yet...
I have but sporlan has not called anyone back yet and that was last fri?
-
05-15-2006, 02:39 PM
Thread: Electric Expansion Valve
by miller2000- Replies
- 8
- Views
- 1,626
I got on the sporlan web site and found the valve...
I got on the sporlan web site and found the valve I'm looking for but I can't seem to got a price for the sei 1.5 and esx-14 has anyone used this and if so where can I get it I also need the...
-
05-11-2006, 09:24 AM
Thread: flow meter
by miller2000- Replies
- 1
- Views
- 414
where can I get a flow meter to see the rate of...
where can I get a flow meter to see the rate of flow in the refrigeration
-
05-11-2006, 08:47 AM
Thread: txv
by miller2000- Replies
- 4
- Views
- 531
I have a 2 ton compressor can I use a 6 ton txv ??
I have a 2 ton compressor can I use a 6 ton txv ??
-
03-05-2005, 05:47 PM
Thread: 9620
by miller2000- Replies
- 0
- Views
- 826
problem== robertshaw 9620 t-stat the check light...
problem== robertshaw 9620 t-stat the check light will give fault code but will also flash like a power lose any ideas???
-
03-02-2005, 08:16 PM
Thread: york
by miller2000- Replies
- 24
- Views
- 1,401
I DETERMINED THAT THERE IS A PRESURE DROP IN THE...
I DETERMINED THAT THERE IS A PRESURE DROP IN THE CONDENSER WHICH IS THE INDOOR COIL IN HEAT MODE. AS YOU KNOW THERE SHOUD NOT BE A PRESSURE DROP. I ALSO TOOK OUT THE ORIFICE AND FOUD THAT TO BE THE...
-
03-01-2005, 07:05 PM
Thread: york
by miller2000- Replies
- 24
- Views
- 1,401
FACTORY HAD A 53 BUT I NEEDED A 55
FACTORY HAD A 53 BUT I NEEDED A 55
-
03-01-2005, 05:58 PM
Thread: york
by miller2000- Replies
- 24
- Views
- 1,401
TODAY I WENT BACK WITH THE IDEA TO CHECK IF THER...
TODAY I WENT BACK WITH THE IDEA TO CHECK IF THER IS A PRESSURE DROP OVER THE INDOOR COIL AND THERE WAS HAD 160 ON MY VAPOR LINE AND 85 ON MY LIQUID LINE COMING FROM THE CONDENSER.
-
03-01-2005, 08:55 AM
Thread: york
by miller2000- Replies
- 24
- Views
- 1,401
I also checked the temp differance in the...
I also checked the temp differance in the revesing valve, and the fiter dryer, and the comp did a pump down.
-
03-01-2005, 08:53 AM
Thread: york
by miller2000- Replies
- 24
- Views
- 1,401
are sight glasses good for res hvac ?
are sight glasses good for res hvac ?
-
02-28-2005, 09:12 PM
Thread: subcooling
by miller2000- Replies
- 17
- Views
- 1,645
how acurate would that superheat reading be with...
how acurate would that superheat reading be with the evap outside
-
02-28-2005, 09:08 PM
Thread: subcooling
by miller2000- Replies
- 17
- Views
- 1,645
any range tht you go by for subcooling ??
any range tht you go by for subcooling ??
-
02-28-2005, 09:02 PM
Thread: york
by miller2000- Replies
- 24
- Views
- 1,401
I didn't check the coil in the house but the...
I didn't check the coil in the house but the outside unit has a orifice and it is the right size . What would subcooling tell me if I were to take it now???
-
02-28-2005, 08:55 PM
Thread: subcooling
by miller2000- Replies
- 17
- Views
- 1,645
orifice
orifice
-
02-28-2005, 08:47 PM
Thread: york
by miller2000- Replies
- 24
- Views
- 1,401
I closed the king valve on the liquid line the...
I closed the king valve on the liquid line the unit pumped down in the inside coil. 30 F outside suction pressure went to 15psig and discharge went to 160 turned off comp suct rose to 25 and...
-
02-28-2005, 08:13 PM
Thread: subcooling
by miller2000- Replies
- 17
- Views
- 1,645
what do you do subcooling or superheat inheat...
what do you do subcooling or superheat inheat mode of a heat pump
-
02-28-2005, 08:00 PM
Thread: york
by miller2000- Replies
- 24
- Views
- 1,401
I weighed the charge in and acounted for the line...
I weighed the charge in and acounted for the line set ,but if it was wouldn't th head pressure show for the overcharge....
-
02-28-2005, 07:17 PM
Thread: york
by miller2000- Replies
- 24
- Views
- 1,401
did a pump down and that went well i thought
did a pump down and that went well i thought
-
02-28-2005, 07:15 PM
Thread: york
by miller2000- Replies
- 24
- Views
- 1,401
this is a efh 18 unit my readings first told me...
this is a efh 18 unit my readings first told me that the compreser was passing and the reversing valve had temp diff and so did the filter dryer? I replaced that and my temp coming out of the...
-
02-28-2005, 07:12 PM
Thread: york
by miller2000- Replies
- 24
- Views
- 1,401
dis was 85 sucwas 45
dis was 85 sucwas 45
-
02-28-2005, 07:05 PM
Thread: york
by miller2000- Replies
- 24
- Views
- 1,401
what will make a heat pump in heat mode have a...
what will make a heat pump in heat mode have a low head and hi suc????????
-
02-25-2005, 06:43 PM
Thread: york
by miller2000- Replies
- 10
- Views
- 919
just had the york people here today hope the...
just had the york people here today hope the problem is resolved. The only thing wefound was the way the humid was hooked up, rewired the unit with a current sensing relay and the home owners wonted...
-
02-17-2005, 07:28 PM
Thread: york
by miller2000- Replies
- 10
- Views
- 919
I tested the senser by temp and resis and it was...
I tested the senser by temp and resis and it was good.