overflow
We have had 3 geo systems that after running about 9 months to 1 year on a pressureless system all of a sudden overflow fluid from the QT center, we have flushed them with the flush cart until all...
-
12-11-2007, 09:37 PM
Thread: nozzle size/type
by joe2003- Replies
- 5
- Views
- 587
Thank You cmajerus
Thank You cmajerus
-
oil
Worked on old quaker oil stove today and oil regulator not working properly. Model #HB4308D60. S#37914. Is there a company out there that still sells this type of equipment. I want to replace this...
-
If it would stop a leak why would one not like...
If it would stop a leak why would one not like it? Is it harmful for compressor?
-
I have a customer with a refrigerant leak in his...
I have a customer with a refrigerant leak in his lineset which is in a wall which goes up 3 stories to an evaporator in the attic. I did an isolation test on system to determine that leak was there....
-
What are the reasons for a compressors internal...
What are the reasons for a compressors internal overload to open?
-
sublimation was the term i was looking for. Thank...
sublimation was the term i was looking for. Thank you
-
very funny everyone, but i still haven't seen an...
very funny everyone, but i still haven't seen an answer. LOL
-
if one were to change 32 degree ice to a vapor,...
if one were to change 32 degree ice to a vapor, what is the term used to describe this?
-
I went on an oil furnace maintenance a couple...
I went on an oil furnace maintenance a couple months ago and serviced system. Routine maint.. I don't have my readings in front of me right now to tell you but everything was running and ok. ...
-
09-28-2005, 05:49 PM
Thread: stack temp
by joe2003- Replies
- 12
- Views
- 1,515
furnace approximately 8-9 yrs old
furnace approximately 8-9 yrs old
-
09-28-2005, 05:48 PM
Thread: stack temp
by joe2003- Replies
- 12
- Views
- 1,515
filters are clean, vents open. Bard furnace, I...
filters are clean, vents open. Bard furnace, I don't have the model and serial # at this time with a becket burner, I believe the model was AG but I am not certain.
-
09-27-2005, 07:29 PM
Thread: stack temp
by joe2003- Replies
- 12
- Views
- 1,515
Oil furnace no.2 fuel oil. What would a normal...
Oil furnace no.2 fuel oil. What would a normal stack temperature be, what would be considered too high or too low? If too high what would be causes and if too low, causes. I have been told between...
-
08-11-2005, 06:53 PM
Thread: capacitors
by joe2003- Replies
- 7
- Views
- 850
Am I not asking the question right?
Am I not asking the question right?
-
08-11-2005, 06:11 PM
Thread: capacitors
by joe2003- Replies
- 7
- Views
- 850
What causes the high voltage reading across the...
What causes the high voltage reading across the terminals of a run capacitor??
-
06-30-2005, 09:13 PM
Thread: low cooling
by joe2003- Replies
- 5
- Views
- 613
been up for 7 days
been up for 7 days
-
06-30-2005, 09:12 PM
Thread: low cooling
by joe2003- Replies
- 5
- Views
- 613
units been on for 3 7 days, bulb is not...
units been on for 3 7 days, bulb is not insulated. I am having this debate in another post about the insulated txv. That post was from today, go ckeck it out. I think that is the problem too
-
Originally posted by beenthere [B]With a...
[QUOTE]Originally posted by beenthere
[B]With a txv, if you take your indoor wetbulb, you know what your keaving drybulb temp should be.
Does it get to set point but continue to run, or is the... -
indoor wet bulb not taken because txv metering...
indoor wet bulb not taken because txv metering device, od ambient 85-90, I took coil delta but i'm not sure what it was at this time, complaint is unit not shutting off
-
go to my earlier post to get that info, thanks
go to my earlier post to get that info, thanks
-
then why does my suction pressure never move, do...
then why does my suction pressure never move, do u think the the TXV could be stuck open and refrigerant is free flowing through coil??
-
inside the plenum or inside the coil case what is...
inside the plenum or inside the coil case what is the difference, because i don't understand
-
it was not a cased coil. sheet metal was built...
it was not a cased coil. sheet metal was built around the coil, thats what i call the plenum, am i incorrect?????
-
final answer
final answer
-
Does a TXV bulb need to be insulated if it is...
Does a TXV bulb need to be insulated if it is inside the plenum on the outlet of the evaporator?? I have a new replacement that has low cooling and the unit runs all the time. I spoke of this unit...