Search:

Type: Posts; User: FrostGiant

Page 1 of 3 1 2 3

Search: Search took 0.00 seconds.

  1. Replies
    7
    Views
    379

    The IPT book is actually published in Alberta, I...

    The IPT book is actually published in Alberta, I went to school in New Brunswick. Ask some of the older guys around in the trade they may have one, even the pipe fitters.
    I'm a service tech so I...
  2. Replies
    7
    Views
    379

    Swagelok Tube Bending Guide. I bought the book...

    Swagelok Tube Bending Guide. I bought the book and little slide rule, but they also published the info online.
    Also, the book "IPT'S Pipe Trades Training Manual" is an excellent resource. I picked...
  3. Thread: lunch ideas

    by FrostGiant
    Replies
    41
    Views
    2,840

    Protein Bars, Sweet Potato Chips, Mixed...

    Protein Bars, Sweet Potato Chips, Mixed Nuts/Flavored Nuts. Very quick and easy, can eat while driving and simple to prepare.
    Have lots of water or ice water available throughout the day. I bring...
  4. Replies
    0
    Views
    189

    Heat Gain Calculation - Transformers

    When sizing cooling equipment for a MCC Electrical room is there an accurate way to calculate the heat gain from large transformers.
    Is it as simple as KVA x 3.413 , or are there other factors to...
  5. http://cms.esi.info/Media/productImages/Tour_Ander...

    http://cms.esi.info/Media/productImages/Tour_Andersson_Ltd_STAD_balancing_valve_1.jpg
    Something like this?
  6. Replies
    21
    Views
    1,210

    http://di3-1.shoppingshadow.com/pi/i.ebayimg.com/0...

    http://di3-1.shoppingshadow.com/pi/i.ebayimg.com/00/$(KGrHqN,!qkFDkQhHZgbBQ-UefyseQ~~_32-450x450-0-0.JPG

    http://ecx.images-amazon.com/images/I/31fbN5jIpfL.jpg
  7. Replies
    0
    Views
    174

    Ultrasonic Water Flow Meters

    Does anybody have any recommendations on what a good flow meter is on the market today? What are the price ranges for these?
  8. Replies
    6
    Views
    541

    I came across a company called Turbotec that...

    I came across a company called Turbotec that actually offers titanium/stainless steel coax coils, but haven't found much in terms of capacties, flow rates, dimensions and whatnot. Does anybody have...
  9. Replies
    6
    Views
    541

    We usually set the head pressure around 225-235...

    We usually set the head pressure around 225-235 on these systems, they're R-22. If there were ever a loss of water pressure or a restriction in the system causing the head pressure to rise, I'd...
  10. Replies
    6
    Views
    541

    What about brazed plate HXs? The plates are...

    What about brazed plate HXs? The plates are stainless steel but the brazing material is either copper or nickel. The water would still come in contact with the copper so I don't think I'd be any...
  11. Replies
    6
    Views
    541

    Cupronickel Condensers

    Does anybody here have experience with cupronickel condensers? How do they hold up in comparison to standard copper for water with moderate to high chlorine content? I checked with my supplier and...
  12. Replies
    8
    Views
    301

    As long as it was quiet enough, I have no...

    As long as it was quiet enough, I have no objections. Very sensitive to noise when sleeping. Could always insulate the compressor with acoustic lining?
  13. Replies
    8
    Views
    301

    Yes, a basement apartment.

    Yes, a basement apartment.
  14. Replies
    8
    Views
    301

    This is in a apartment so mini split is not an...

    This is in a apartment so mini split is not an option, not allowed to have penetrations through outside wall.
  15. Replies
    8
    Views
    301

    Small capacity window air conditioner

    Any recommendations on a small capacity (<5,000 btu) window air-conditioner. This is for a bedroom so low sound levels are essential. The room is just 100 sq.ft and in a basement.
  16. If you are referring to mini splits, Mitsubishi...

    If you are referring to mini splits, Mitsubishi has just released a system designed for server rooms with a higher sensible heat ratio (80-90%) and rated for continuous operation, even at -40C. It's...
  17. Replies
    21
    Views
    1,478

    I would not be concerned about a minimum suction...

    I would not be concerned about a minimum suction gas temperature as long as there is positive superheat. Oil dilution, flooding and slugging would be more of an issue at that point.
    I've seen low...
  18. Replies
    21
    Views
    1,478

    65F is the maximum recommended suction gas...

    65F is the maximum recommended suction gas temperature for a hermetic compressor in a air-conditioning or high-temp application.
  19. Replies
    14
    Views
    641

    Mastercraft from Canadian Tire has an open end...

    Mastercraft from Canadian Tire has an open end ratcheting wrench set.
  20. Replies
    0
    Views
    289

    ASHRAE Journal Back Issues

    Does anybody know where to purchase back issues of Ashrae Journal for a decent price? I'm looking for issues from the past couple of years mainly, but would consider older ones.
  21. Replies
    23
    Views
    1,822

    Every 2 degress of subcooling will increase...

    Every 2 degress of subcooling will increase evaporator capacity by 1%.
  22. Replies
    24
    Views
    1,724

    This is the AOP forum... only vetted members may...

    This is the AOP forum... only vetted members may post in the AOP area due to the DIY rules.

    Post removed.
  23. Replies
    24
    Views
    1,724

    I have the exact same unit, has been running...

    I have the exact same unit, has been running steady for about 2 years now.

    There is a condensate pump in the drain pan on the unit. As the condensate level rises, the float activates and pumps...
  24. Replies
    6
    Views
    763

    I thought prestolite was just another name for...

    I thought prestolite was just another name for air/acetylene. I use the TurboTorch setup with quick connects and the standard B Tank. The tips are use are the a-11,1-14 etc.. Will they fit with my...
  25. Replies
    6
    Views
    763

    The Cap'n hook is for Oxy as far as I can tell, I...

    The Cap'n hook is for Oxy as far as I can tell, I do not have an oxy rig, just straight acetylene. Do you have a link?
Results 1 to 25 of 73
Page 1 of 3 1 2 3
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event