Search:

Type: Posts; User: incontrol

Page 1 of 20 1 2 3 4

Search: Search took 0.02 seconds.

  1. Replies
    1
    Views
    162

    Niagara login screen restarts

    After logging in the menu bar at the top starts to appear but then the login screen reappears. Rinse and repeat.
  2. Chpreak wins.

    Chpreak wins.
  3. If it is reading about 4 or 5 Kohm then it has...

    If it is reading about 4 or 5 Kohm then it has the shunt.
  4. Replies
    4
    Views
    428

    Is there a way through Niagara G3 WorkBench to...

    Is there a way through Niagara G3 WorkBench to log into multiple ENC/ENS stations without being re-prompted for the Username and Password for each station?
    -------------------------------------

    ...
  5. Geek: Is there anything I can do without...

    Geek: Is there anything I can do without software?

    Phreak: Can you give me an example of your thingamajig?

    This has happened before. Trane comes back and monkeys with it and then bills us.
  6. Replies
    4
    Views
    428

    used to work with R2 ---------------------- ...

    used to work with R2
    ----------------------


    In the Address Bar, type in the following: \\[user]:[password]@[host]:[port]

    where:

    [user] = the user name of the station
  7. Trouble discovering Trane chiller with AX

    So the Trane tech was there starting up a new chiller w/ bacnet. He told me to land wires on the LINK terminals on this white controller. I hooked up the wires and couldn't discover anything. ...
  8. Replies
    10
    Views
    422

    The yellow light should be quickly going on/off....

    The yellow light should be quickly going on/off. If it is on solid or going from bright to dim without fully going out you have a comm problem. That comm problem could actually be somewhere else and...
  9. Replies
    11
    Views
    650

    Sounds serious. I just went ahead and changed it...

    Sounds serious. I just went ahead and changed it so we'll go from here. Thanks.
  10. Atouk ZugZug Tala!

    Atouk ZugZug Tala!
  11. Replies
    11
    Views
    650

    Same guy different jace. I've got a jace that...

    Same guy different jace. I've got a jace that where the platform defaults were changed and I can log in because my login 'remembers' the password but I don't have it. I can get into the jace but...
  12. That works great mmelillo. I will have to...

    That works great mmelillo. I will have to commission a lot of AHUa & AHUbs and go by their addresses though.
  13. A way to relativize two points containers?

    Is there a good (or any) way to relativize two points containers? I have AHUs that has have two controllers but usually a graphic sits on top of a single points container. I tried cutting the...
  14. What is the absolute cheapest controller with a history?

    I want to put a CT on my well pump and check the history. I think it is cycling all night when there is no water being used.
  15. Replies
    6
    Views
    330

    The network 8000 line has been discontinued so I...

    The network 8000 line has been discontinued so I believe the software should be free. What do you mean you have difficulty "copying " the software to the latest operating system such as windows 7? ...
  16. Replies
    7
    Views
    640

    What are your objectives? Is this for tech...

    What are your objectives? Is this for tech troubleshooting of end devices or AX programming? I'm amazed at how many techs don't understand milliamps, changing ma to volts w/ a resistor, etc. Do you...
  17. When I edit it I don't get the %.% ...

    When I edit it I don't get the %.%

    <BoundLabel name="BoundLabel14" layout="210.0,300.0,100.0,20.0" halign="left">
    <BoundLabelBinding name="BoundLabelBinding"...
  18. Need help understanding Ashrae equation 6.1

    Ashrae standard 62-89 ventilation recalculation equation 6.1 (a pretty good writeup here http://www.seedengr.com/Ventilation%20and%20Fan%20Pressure%20Optimization%20for%20VAV%20Systems.pdf) says the...
  19. Yes, fast & easy. Thanks.

    Yes, fast & easy. Thanks.
  20. Replies
    7
    Views
    241

    I think so. Did you try pasting a shadow object...

    I think so. Did you try pasting a shadow object and manually entering the Neuron?
  21. Is there a way to enable ALL numercail interval histories in AX?

    I hate the way they are disabled when I copy/paste. I would like a global enable just in case I misssed any also.
  22. Thanks. Any I drag out now are ok. The summary...

    Thanks. Any I drag out now are ok. The summary field says %displayName?typeDisplayName% = %.% On the old ones with the {ok} I changed to %out.value% and they did not change. Any way to change...
  23. Why do all of my Niagara points now have {ok}?

    In the middle of a job all of a sudden all of my Bacnet points I drag onto the screen now have {ok} after them. Can't finger out why.
  24. Replies
    8
    Views
    463

    We use the weather service broadcast because it...

    We use the weather service broadcast because it includes lots of other data and forecasts. We also install local sensors as backup in case of communication problems. It's not a replacement.
  25. Replies
    11
    Views
    673

    Have you checked the station for standard links...

    Have you checked the station for standard links like occupancy and setpoint? Are the fans running during occupancy or just cycling?