  1. Your duct work is in poor shape. I think I can...

    Your duct work is in poor shape. I think I can see a take off at the end of the trunk which is a no-no. You need to have at least 14 inches at the end of the trunk . Your best option is new duct work...
  2. I have had 2 cond fan motors quit after running a...

    I have had 2 cond fan motors quit after running a while. One of them quit while I was putting tools away; I got lucky on that one.
  3. have the tech install data loggers

    have the tech install data loggers
  4. Replies
    25
    Views
    1,092

    I found that if you turn auto zeroing off, you...

    I found that if you turn auto zeroing off, you can zero it out yourself and get to the leak area better.
  5. Replies
    25
    Views
    1,092

    have had excellent results on R410 with the SLR8

    have had excellent results on R410 with the SLR8
  6. Replies
    28
    Views
    761

    I use a 2005 Sprinter 2500 158 wheel base. FULLY...

    I use a 2005 Sprinter 2500 158 wheel base. FULLY loaded. 20 miles per gal and better
  7. Replies
    45
    Views
    1,611

    How about telling a 50 yr old wife you'll be...

    How about telling a 50 yr old wife you'll be trading her in for 2 25 yr olds instead?
  8. Replies
    13
    Views
    267

    A lot of the newer refrigerators have defrost...

    A lot of the newer refrigerators have defrost thermisters that cause freezing coils. You might want to let it defrost manually and see if it cools better.
  9. A+ at BBB is a joke many times. The BBB is after...

    A+ at BBB is a joke many times. The BBB is after the business' $$$ for membership only.
  10. Replies
    15
    Views
    745

    If the manual J was done accurately, I would be...

    If the manual J was done accurately, I would be looking at a 2.5 ton with duct modifications, single stage or 2 stage if you can afford it. I like single stage due to the fact that you suffer line...
  11. Replies
    12
    Views
    522

    ICM 255

    ICM 255
  12. Replies
    12
    Views
    413

    SH, SC, static pressures,wb,db, ambient...

    SH, SC, static pressures,wb,db, ambient temp,...give us something. Get your post count up and apply for pro membership. You will not get much info in the open forum.
  13. I have the Fieldpiece SLR8 which is their heated...

    I have the Fieldpiece SLR8 which is their heated diode detector. It works great on R410 but not so good on R22. The SLR8 picked up a lerak that my H10 missed. I did not bump up the sensor adjustment...
  14. Replies
    47
    Views
    1,217

    Peterpan, If there is a leak, as long as there...

    Peterpan,
    If there is a leak, as long as there is refrigerant in the system, air can not enter so that is not a problem. Some hot water recovery units have bad components in them so that needs...
  15. Replies
    19
    Views
    381

    We are speaking of air handlers.

    We are speaking of air handlers.
  16. Replies
    19
    Views
    381

    I have had multiple breakers go bad in air...

    I have had multiple breakers go bad in air handlers.
  17. Replies
    19
    Views
    381

    I just eliminate the breaker in the Ah and use a...

    I just eliminate the breaker in the Ah and use a disconnect next to the Ah. If the Ah is in a garage and the breaker panel is there , I do not install and disconnect as long as I have direct line of...
  18. Replies
    6
    Views
    345

    I would run N2 thru it to keep the flames at a...

    I would run N2 thru it to keep the flames at a minumin. The heat will ignite the oil.
  19. Replies
    29
    Views
    1,366

    The Appions work but when you push the tip into...

    The Appions work but when you push the tip into the valve, you must push harder to get the vlave core to engage the tool.
  20. Replies
    40
    Views
    1,495

    pull txv bulb loose and use a cup of hot and cold...

    pull txv bulb loose and use a cup of hot and cold water to see if pressures change. Check the static pressures
  21. Replies
    13
    Views
    516

    looks like an ICP unit. It is an ECO-Temp.

    looks like an ICP unit. It is an ECO-Temp.
  22. Replies
    13
    Views
    516

    and the model numbers are????

    and the model numbers are????
  23. Replies
    9
    Views
    315

    Use the true suction port

    Use the true suction port
  24. Replies
    38
    Views
    719

    Yes it could be wrong orfice. 35 SC indicates...

    Yes it could be wrong orfice. 35 SC indicates overcharge also. Refrigerant is backed up in condenser. Measuring duct supplies at vents won't help as they will pick up heat. Make temp measurements of...
  25. Replies
    38
    Views
    719

    Did it ever stay conmstant? Could be the wrong...

    Did it ever stay conmstant? Could be the wrong sized metering device. Also, there may be trash preventing the orfice from seating properly. I would pump it down and open up the liquid line tom check...