    thanks for the info

    thanks for the info
  2. Replies
    12
    Views
    693

    Nothing was said about changing the reversing...

    Nothing was said about changing the reversing valve when the compressor was changed and considering the problem did not go away the problem source looks to be heading in that direction. No issues in...
  3. Replies
    12
    Views
    693

    HP reading taken on hot gas line and the noise is...

    HP reading taken on hot gas line and the noise is a prolonged as many people have commented on it when visiting.
  4. Replies
    12
    Views
    693

    aux heater is 15 kw and when I saw the 96...

    aux heater is 15 kw and when I saw the 96 degree SA temp I went and checked to see if aux heat was energized and it was not( Honeywell focus pro 8000 touch screen). Thinking I am going to have to...
  5. Replies
    12
    Views
    693

    ]The numbers are bothering me. You've only got...

    ]The numbers are bothering me. You've only got about a 4* TD at the outdoor unit, and an indoor SCT of about 84* at 250 psi. You have a delta-t of 26* with a 69* return, giving you about a 95*...
  6. Replies
    12
    Views
    693

    Are you working on a HPXA16, or an XP16? Is it a...

    Are you working on a HPXA16, or an XP16? Is it a CB31MV, or a CBX32MV? HPXA16 with CBX32MV
    Head pressure only 250 on a 45 degree day - was it pretty cool in the house? Return air at 69
    You heard...
  7. Replies
    12
    Views
    693

    Lennox HPX16 036 / CBMV36

    I attend to a new customer yesterday for a general heat pump maintenance check. They explained to me there on going problem with the system they had installed in 2008.
    The complaint is a high...
  8. was thinking overnight....maybe water fill valve...

    was thinking overnight....maybe water fill valve is not fully closing. keep water temp higher not allowing cold water for proper ice formation
  9. Ok thanks for the update. Pin count is set for 12...

    Ok thanks for the update. Pin count is set for 12 on G1 less 85 ambient and less the 68 water temp.
  10. Spika ice machine undercounter Model 125-A1H

    any one have any trouble shooting experience with unit.

    very poor ice production meaning poor cube formation before defrost
    new water curtain installed and distribution pipe as previous was...
  11. Replies
    12
    Views
    756

    original post indicates .1SP on RA plenum before...

    original post indicates .1SP on RA plenum before filter....no way of getting true SP after coil and filter
  12. Replies
    12
    Views
    756

    Good to know and confirms to me at least that...

    Good to know and confirms to me at least that dropping the air speed proved my theory
  13. Replies
    12
    Views
    756

    according to installation instruction this is a...

    according to installation instruction this is a multi position coil and this did not start on day one of installation so it work for a while
  14. Replies
    12
    Views
    756

    traped and primed

    traped and primed
  15. Replies
    12
    Views
    756

    Since dropping the fan speed, water issues have...

    Since dropping the fan speed, water issues have ceased. To me that proves my suspicion about the filter.
  16. Replies
    12
    Views
    756

    no furnace.. typical heat pump air handler. "A"...

    no furnace.. typical heat pump air handler. "A" coil above blower and heater, filter above coil then the ra plenum box
  17. Replies
    12
    Views
    756

    Condensate issues in downflow application

    I have inherited a problem that has been on going for about 4years

    Lennox CB29M-46-1P
    Matched with a 4ton 10seer Armstrong concept ac

    condensate is soaking the blower and heater compartments...
  18. Replies
    9
    Views
    1,016

    good point on the brazing...I can only assume...

    good point on the brazing...I can only assume they are doing it correctly...but then again. I will pass on about the service bulletin info. Can you provide bulletin??
  19. Replies
    9
    Views
    1,016

    Indeed they are danfoss valves. I wonder if they...

    Indeed they are danfoss valves. I wonder if they are aware of this issue?
  20. Replies
    9
    Views
    1,016

    These would be in Frigidaire heat pumps

    These would be in Frigidaire heat pumps
  21. Replies
    9
    Views
    1,016

    Nordyne R410 TXV failures

    I was in the local supplier today and I was asked if I had ever seen failures such as ruptured power heads and sensing bulbs that have blown off. He has a collection of returned txv's. I am not a...
  22. Replies
    12
    Views
    2,107

    the jury rigged fan on a combo wood oil heater

    the jury rigged fan on a combo wood oil heater
  23. Replies
    12
    Views
    2,107

    refrigerant suction line on a heat pump

    refrigerant suction line on a heat pump
  24. Replies
    12
    Views
    2,107

    yep on a rinnai on demand 199,00 btu be utilized...

    yep on a rinnai on demand 199,00 btu be utilized as backup supply for radiant infloor...not my install but is now my problem
  25. What did you find ...anymore head way? I am a...

    What did you find ...anymore head way? I am a york dealer as well. I feel your pain. I had a problem with these comm stats as well, however my system when set in auto.. heat 70 cool 74. whenever...