  1. Replies
    0
    Views
    681

    Are KSB pumps UL listed

    Are KSB pumps UL listed. Second, should I go for a split case or end suction (horizontal) for delivering 750gpm in a fire sprinkler network. Thanks
  2. Replies
    5
    Views
    2,059

    @jerreau It is 18000cfm AHU and I have been...

    @jerreau
    It is 18000cfm AHU and I have been installing attenuators in my previous designs in the supply air ducts. Looks like you are right, these are mostly customized built AHUs which have...
  3. Replies
    5
    Views
    2,059

    I have looked few catalogs, Carrier, Trane for...

    I have looked few catalogs, Carrier, Trane for instance but don't find any attenuators inside the AHU.
  4. Replies
    5
    Views
    2,059

    Built in sound attenuators in AHU

    Are there any such AHUs avialable which have built in sound attenuators. Meaning inside the AHU body, immediately after the blower fan...there is sound attenuators. Thanksj
  5. Replies
    2
    Views
    1,022

    Height of air duct inside warehouse

    What should be the approximate height of a supply air duct inside a warehouse whose side walls are 6 meters high and racks for storing goods would be 5 meters high. I am more interested in knowing...
  6. Replies
    9
    Views
    1,201

    Thanks 2sak

    Thanks 2sak
  7. Replies
    5
    Views
    1,229

    @Alcomech - pre insulted pipes are not in much...

    @Alcomech - pre insulted pipes are not in much use here. Usually it's the PVC or Carbon Steel that we use for the embedded lengths of pressure pipes.
  8. Replies
    5
    Views
    1,229

    Underground chilled water pipes

    I have to embed around 15 meters of chilled water supply and return lines. I will give them min two coates to epoxy paint, insulate them with rigid fiber glass pipe insulation having vapor barrier...
  9. Replies
    9
    Views
    1,201

    My concern was, that DS put inside should not get...

    My concern was, that DS put inside should not get effected with the moist environment inside. So no issues I suppose, one should go for weather proof ones I guess. Thanks anyway.
  10. Replies
    9
    Views
    1,201

    Cold storage room evaporating coolers

    I am in the process of *designing a cold storage room, where should I provide the disconnect switch for the evaporating coolers (2 nos) and lighting fixtures. Should it be inside the cold storage...
  11. Replies
    10
    Views
    2,302

    Must say this thread has been a source of great...

    Must say this thread has been a source of great info for me and gave me a chance to revise psychrometrics. Just little curious to know about adding humidifiers on the supply air way, if someone could...
  12. Replies
    10
    Views
    2,302

    Thanks a lot thermojohn and beenthere for...

    Thanks a lot thermojohn and beenthere for explaining it so nicely. I am pretty clear now. Little extension to the same subject.....I have also been designing stream humidifiers / humidistats in the...
  13. Replies
    10
    Views
    2,302

    @beenthere, Still 80% sounds too high. Don't you...

    @beenthere,
    Still 80% sounds too high. Don't you think if air with that % age of moist content will enter through diffuser inside the room, would make most of the diffusers look like sweating with...
  14. Replies
    10
    Views
    2,302

    Moisture content at supply diffuser inside room

    Is it true that the moisture content of the air when it enters the conditioned room via supply air diffuser would be around 90%. I have designed the room at 50% RH but am bit confused after one of my...