  1. Replies
    22
    Views
    3,035

    Thank you. Actually I never heard about that term...

    Thank you. Actually I never heard about that term "water hammer". But now I'm know it.



    Thank you, I got it.
  2. Replies
    22
    Views
    3,035

    Dear desert guy, I'm forgot what the reading at...

    Dear desert guy,
    I'm forgot what the reading at pressure gauge. I'm always use that pressure sensor with max pressure is 300psi.




    Dear Nuclrchiller
    What is water hammer ? Can you explain...
  3. Replies
    22
    Views
    3,035

    Hi guy, I'm using this type of sensor...

    Hi guy, I'm using this type of sensor http://www.dwyer-inst.com/Product/Pressure/SinglePressure/Transmitters/Series626-628
    Before this I'm never use "pigtail". But some site that use this sensor got...
  4. Replies
    22
    Views
    3,035

    Thank you for the link and info. Dear...

    Thank you for the link and info.



    Dear Nuclrchiller,

    I'm also afraid without "pigtail" will be damaged the sensor. This sensor will be use for control VSD pump. Maybe the best choice is to...
  5. Replies
    22
    Views
    3,035

    Is it without "pigtail" will be effect for the...

    Is it without "pigtail" will be effect for the water pressure reading? For information, this water pressure is to control VSD pump.
  6. Replies
    22
    Views
    3,035

    Water Pressure Sensor transmitter installation

    Hi expert forumer,

    I need advice to install water pressure transmitter at Chiller water pipe, I have two option to install whether to use copper tube or not. Please refer to image attachment for...
  7. Replies
    15
    Views
    2,063

    Thank you Exwtk, I understand it the function to...

    Thank you Exwtk, I understand it the function to control it.
  8. Replies
    2
    Views
    1,161

    Sir, Only 2 DDC involve in this OT Room. Both...

    Sir,
    Only 2 DDC involve in this OT Room. Both DDC cannot share information to each other. One DDC control the heater to maintain Humidity and the other DDC control the Valve to maintain the...
  9. Replies
    2
    Views
    1,161

    Control Strategy for AHU OT Room

    Hi,

    I'm got some question regarding to Operation Theater (OT) Room control strategy.

    Is it possible this control strategy :-

    Room Humidity - Control by other controller ( standlone DDC )...
  10. Replies
    15
    Views
    2,063

    Thank you for clear explanation, I think that...

    Thank you for clear explanation, I think that take a lot of time to tuning the PID for VSD and valve :(
  11. Replies
    15
    Views
    2,063

    Thank you for suggestion, xarralu and crab...

    Thank you for suggestion, xarralu and crab master.
    my mistake for Delta T.
    So, Delta T for control bypass and Delta P for control Variable Speed Drive Pump. May I know why need to place the sensor...
  12. Replies
    15
    Views
    2,063

    Need Advice to place Pressure Sensor

    Hi expert forumer,

    I'm beginner in control automation. I'm need some advice from all of you regarding to this

    1) which is best location to place water pressure sensor to control Variable Speed...
  13. Replies
    19
    Views
    2,789

    Im working with ASI Control devices. The devices...

    Im working with ASI Control devices. The devices running with software and hardware that easy to configure. The hardware can be interface with all type of binary input/output and also analog output....
  14. Replies
    10
    Views
    1,684

    For small building, use only standalone networks...

    For small building, use only standalone networks thermostat. that reduce the cost.
    bacnet is not good choice for me. better use OPC server for equipment.
    im suggest this equipment to interface...