  1. I just looked. The information you seek is in the...

    I just looked. The information you seek is in the UI installation manual. If your installer cannot figure it out they need to make a call for technical support. Is this a new indoor installation?...
  2. The UI must be told the AC is there. AC connects...

    The UI must be told the AC is there. AC connects to furnace. The info is in the install manuals for your equipment
  3. Replies
    23
    Views
    520

    Carrier furnace coils are all aluminum

    Carrier furnace coils are all aluminum
  4. Replies
    23
    Views
    520

    2" should work.

    2" should work.
  5. Replies
    23
    Views
    520

    Depends on the size of the furnace and length of...

    Depends on the size of the furnace and length of run.
  6. Replies
    23
    Views
    520

    Since the water heater does not use the chimney,...

    Since the water heater does not use the chimney, if it is straight they could use it as a chase to run the PVC pipes through to the roof.
  7. Replies
    36
    Views
    1,167

    The furnace condensate drain does not comply with...

    The furnace condensate drain does not comply with the installation instructions. It must be vented.

    Your installer needs to read the install manual and install the unit as Carrier specified.
  8. Replies
    36
    Views
    1,167

    That furnace with intake from outside is a sealed...

    That furnace with intake from outside is a sealed vestibule.

    1) Both flanges are required to have gaskets between them and the cabinet.
    2) Flanges are to be aligned with knockouts.
    3)...
  9. How big is the square hole? Can it be enlarged...

    How big is the square hole? Can it be enlarged somewhat easily?
  10. Replies
    36
    Views
    1,167

    Neither pipe is installed properly. Tell them to...

    Neither pipe is installed properly. Tell them to follow he install manual.
  11. Money spent on building envelope improvements...

    Money spent on building envelope improvements would go a long way toward reducing the system size and energy costs. If humidity control is important, step up to the Infinity control.
  12. Replies
    7
    Views
    272

    Try a solid pad or filling the voids in the...

    Try a solid pad or filling the voids in the plastic pad. The harmonics are different with each unit, but I have found when there is an issue the plastic pads make is worse.
  13. Replies
    7
    Views
    272

    Sounds like the lineset is touching the...

    Sounds like the lineset is touching the structure, or the system is charged incorectly, or a combination of the two.
  14. Was the indoor coil installed 2 yrs ago when he...

    Was the indoor coil installed 2 yrs ago when he outdoor was replaced?
  15. Duplicate post!

    Duplicate post!
  16. One possibility is the existing return has air...

    One possibility is the existing return has air leakage from unconditioned space. The dealer may be able to slow the airflow a bit. This will allow the indoor coil to be colder removing more latent...
  17. Replies
    2
    Views
    308

    The bulletin has been updated and should apply to...

    The bulletin has been updated and should apply to your unit - DSB14-0025. You are only obligated to them if you have paid them money. Your best option is to pay for the outdoor unit under the...
  18. Probably best to buy the propane to NG kit for...

    Probably best to buy the propane to NG kit for the furnace. This way you are assured all the parts are correct.
  19. No advantage with the Bryant. The OA sensor is...

    No advantage with the Bryant.

    The OA sensor is an option. Have it installed for automatic humidifier control.
  20. 1. Yes, but it requires an extra part. 2. It...

    1. Yes, but it requires an extra part.
    2. It does not use the internet temp for control. Evolution outdoor unit will have the OA sensor. Otherwise it is not difficult to add.
  21. Replies
    13
    Views
    571

    Your dealer has tools available to give you an...

    Your dealer has tools available to give you an operating cost comparison. As mentioned you have several options. You just need to determine the budget you are comfortable with.
  22. Rigid Threading Equipment - 460 Tri-Stand & 600 Power Threader

    http://i386.photobucket.com/albums/oo303/flamborn/2013-10-16132448.jpghttp://i386.photobucket.com/albums/oo303/flamborn/2013-10-16132354.jpg...
  23. Replies
    0
    Views
    269

    VETO Model XL - Barely Used

    http://i386.photobucket.com/albums/oo303/flamborn/2014-07-06151238.jpg

    Couple years old, but in like new condition. $135.00 OBO, shipped to the continental US. PM with questions.
  24. Replies
    57
    Views
    2,101

    Have the refrigerant recovered and recharge the...

    Have the refrigerant recovered and recharge the system by weight. Make certain no water is flowing through the HRU, and verify SH & SC. After that you can determine if a problem exists and...
  25. Replies
    2
    Views
    137

    Are you a tech or a homeowner?

    Are you a tech or a homeowner?