  1. Replies
    17
    Views
    5,562

    What mean: "Support for C-Bus extended...

    What mean: "Support for C-Bus extended attributes" - does it red write time programs?
    "NEW alarm integration" - did it read alarms from C-bus controllers?
  2. Replies
    38
    Views
    2,568

    Ok azzad, but lets do one testing in a mind: You...

    Ok azzad, but lets do one testing in a mind: You build Vista-Xenta 1xx-7xx automation system with as possible open LON, I take Vista out from this system and replace it with only SNVT capable SCADA....
  3. Replies
    38
    Views
    2,568

    Think more, if Xenta 10x series communicates with...

    Think more, if Xenta 10x series communicates with Xenta 2xx-7xx using standard SNVT-s then for building up system only Menta tool is not enough, also Lonmaker or other comissioning tool is needed....
  4. Replies
    38
    Views
    2,568

    Sorry. May last post had missed some details. I...

    Sorry. May last post had missed some details.
    I mean If Xenta 1xx ASC gets time program commands/data from Xenta 2xx-7xx or from Vista it makes Xenta 1xx ASC data communication not fully open....
  5. Replies
    38
    Views
    2,568

    If Xenta ACS are under Vista and time programs...

    If Xenta ACS are under Vista and time programs are from Xenta they are not fully open. To program Xenta controller open it takes double work than closed one.
  6. Replies
    38
    Views
    2,568

    big ' * ' must be also added to TAC and small to...

    big ' * ' must be also added to TAC and small to Honeywell.
  7. Replies
    11
    Views
    1,129

    At least from Excelon version 3.05, may-be...

    At least from Excelon version 3.05, may-be earlier.
  8. Replies
    11
    Views
    1,129

    Wrong. HW Excelon can also analyze IP852...

    Wrong.
    HW Excelon can also analyze IP852 channel.
  9. Replies
    65
    Views
    9,442

    Honeywell new system?

    Had You more information on this new system?
  10. Thread: Care 80 lns

    by jomi
    Replies
    3
    Views
    682

    first You must upgrade to Care 5.x and then to 8.x

    first You must upgrade to Care 5.x and then to 8.x
  11. Replies
    2
    Views
    572

    It is (or actually was as E-vision is not...

    It is (or actually was as E-vision is not supported now) possible if you pay real big money to HW.
  12. Replies
    3
    Views
    2,098

    XF800 and XFL800 will replace 500 series, they...

    XF800 and XFL800 will replace 500 series, they are on new element base, cheaper to produce, faster and had non LonMark and LonMark I/O modules. 800 series has no BacNet.
    Picture on the link is not...
  13. Replies
    15
    Views
    2,403

    700 had: # SNVT Inputs - 300 # SNVT Outputs -...

    700 had:
    # SNVT Inputs - 300
    # SNVT Outputs - 300
    # Menta applications - Multiple
    cycle times: 100 ms, 500 ms, 1000 ms, 5 s, 10 s
  14. Thread: Honeywell XC5010C

    by jomi
    Replies
    5
    Views
    1,857

    or CARE 3.x.x and CARE 4.x.x, if you have.

    or CARE 3.x.x and CARE 4.x.x, if you have.
  15. Thread: Honeywell XC5010C

    by jomi
    Replies
    5
    Views
    1,857

    "512 NVs supported for LONWORKS integration" You...

    "512 NVs supported for LONWORKS integration"
    You can create them with CARE.
    Works OK in LON.
    As for all freely programmable CPU-s, if you changes LON NV-s (and it means XIF changes) after binging,...
  16. Replies
    10
    Views
    3,338

    You can use superuser (ask HW if needed) password...

    You can use superuser (ask HW if needed) password to change any level 2 or 3 passwords, no need to reload with CARE.
  17. Replies
    6
    Views
    1,285

    It can be problem with Xentas as TAC Xentas and...

    It can be problem with Xentas as TAC Xentas and Vista system are normally (?) built not to use SNVT-s but own explicit messages on LON. Loytec or Fieldserver can help after someone (?) had modified...
  18. Thread: Lonworks Sniffer

    by jomi
    Replies
    11
    Views
    2,934

    I like http://www.excelon.net/ It can use...

    I like
    http://www.excelon.net/

    It can use the PCC-10, or RNI inside an iLON100 or others.
    Only costly.
  19. Replies
    36
    Views
    3,166

    Not dead yet. As I know, some major HVAC...

    Not dead yet.
    As I know, some major HVAC companies are developing own ZigBee products.
  20. Replies
    5
    Views
    806

    Yes it can be from Loytec, as Honeywell has many...

    Yes it can be from Loytec, as Honeywell has many Loytec products in offer all over the world.
  21. Replies
    2
    Views
    549

    Nobody? Even sysint?

    Nobody?
    Even sysint?
  22. Replies
    2
    Views
    549

    As I have some network communication problems in...

    As I have some network communication problems in LON bus I read once more LonMaker help and find in many places sentence: "which calculates an appropriate value based on network topology".
    Did...
  23. Replies
    8
    Views
    707

    Bootrom update was solution to my problems.

    Bootrom update was solution to my problems.
  24. Replies
    8
    Views
    707

    Yes, its seems silple. I download 3.02 files...

    Yes, its seems silple.
    I download 3.02 files to e2 (1.10) and get problem. No more time setup is possible. I get error like: time is null or object not available. I did not upgrade bootrom, its...
  25. Replies
    8
    Views
    707

    Good to know. How you did e2 update to last SP...

    Good to know.
    How you did e2 update to last SP or it is not needed?
Results 1 to 25 of 93
Page 1 of 4 1 2 3 4