Search:

Type: Posts; User: coryc

Page 1 of 2 1 2

Search: Search took 0.00 seconds.

  1. Replies
    13
    Views
    2,244

    http://www.e-inst.com/combustion-gas-analyzers/pro...

    http://www.e-inst.com/combustion-gas-analyzers/products-BTU1100

    There's a full service oil company here in CT. (Sippin Energy)

    I'm friends with their service manager.

    E-Instruments is the...
  2. Replies
    13
    Views
    2,244

    I personally don't have any experience with...

    I personally don't have any experience with Testo, but I know they had some really good looking specials around here over the winter.

    Field replaceable sensors will keep the analyzers down time...
  3. Replies
    13
    Views
    2,244

    Up here in Connecticut my friends had some poor...

    Up here in Connecticut my friends had some poor turn around times with Testo.

    I know that has also been a complaint with Bacharach also.

    Field replaceable sensors probably will help that now. ...
  4. Replies
    34
    Views
    3,278

    I've got a new this year model Bacharach H10pm...

    I've got a new this year model Bacharach H10pm model that found a leak for a friend of mine in a 4 year old 410A Carrier resi evap coil. He had isolated the components and knew it was in the coil but...
  5. Thread: Oil efficiency

    by coryc
    Replies
    2
    Views
    511

    I recently purchased the Bacharach Fyrite Insight...

    I recently purchased the Bacharach Fyrite Insight and really like it. They have field replaceable PRE-CALIBRATED sensors available on a yearly sensor return program, so the only time you'd have to...
  6. Thread: energy manager

    by coryc
    Replies
    22
    Views
    2,010

    Beenthere mentioned the W/M Ultra Oil, I have one...

    Beenthere mentioned the W/M Ultra Oil, I have one in our cellar and am very happy with it. That boiler is more of a medium-mass boiler and I chose it due to the large water volume of our system (C/I...
  7. Thread: energy manager

    by coryc
    Replies
    22
    Views
    2,010

    Biasi, Riello and any indirect of your choice...

    Biasi, Riello and any indirect of your choice will do a very good job for you. Add to that some form of reset (Tekmar, Beckett Aquasmart, Honeywell AQ) and you'll do very well.
  8. It's been done thousands of times over the years....

    It's been done thousands of times over the years. The problem is the boiler manufacturer does NOT rate that boiler with a gas burner in it. Liability thing.
    Carlin will have specs for doing it i...
  9. Replies
    24
    Views
    7,017

    Buderus G115's with Riello burners have been a...

    Buderus G115's with Riello burners have been a bit touchy the last few years. They have had spec changes constantly (ie. tube insertion depth, nozzle size and pump pressure changes). Riello in the...
  10. Replies
    24
    Views
    7,017

    Both are excellent choices. Personal preference...

    Both are excellent choices. Personal preference is the Biasi with a Beckett NX burner and a Tekmar 260 boiler control. Both units have a very strong northeast presence.....so warranty issues...
  11. Replies
    28
    Views
    5,367

    I can personally vouch for the savings potential...

    I can personally vouch for the savings potential of an ODR. Can't speak for timers, but in europe I understand they use them alot. The only thing I might caution against is modifying the wiring on...
  12. Replies
    28
    Views
    5,367

    Very good advise so far. If I could step in and...

    Very good advise so far. If I could step in and add that an outdoor reset used on the boiler if you're going indirect or electric for your hot water would dramatically decrease fuel usage. A...
  13. Replies
    11
    Views
    1,253

    I use and would recommend the Wohler A500.

    I use and would recommend the Wohler A500.
  14. Replies
    2
    Views
    1,455

    Pricey, but I like it better than the Bach Pro...

    Pricey, but I like it better than the Bach Pro 125 I have. My friend likes it better than his Testo. Also, nice feature to be able to put so much Company info on print-out. Being able to see all info...
Results 1 to 14 of 37