  1. Replies
    6
    Views
    620

    Now the World knows where all the Experts chat !

    Now the World knows where all the Experts chat !
  2. Replies
    11
    Views
    621

    I've had this.,replace the ignitor. I know its...

    I've had this.,replace the ignitor. I know its glowing red hot. Its worked twice for me.I carry Glowfly's,so it probably was not with factory OEM.
  3. Replies
    12
    Views
    631

    Is this furnace in basement?If so would not...

    Is this furnace in basement?If so would not running fan all the time,pull more radon thru the home,unless returns were sealed very well?
  4. Replies
    188
    Views
    14,632

    Over 100 posts,yet no one has posted the original...

    Over 100 posts,yet no one has posted the original factory bulletin!
  5. Replies
    11
    Views
    489

    Condensating furnaces are not a good idea up here...

    Condensating furnaces are not a good idea up here in the north for seasonal homes,That said I've always wondered if you added a "switch" to run inducer fan with not heat for an hour or so,if it would...
  6. Replies
    6
    Views
    315

    One tip I have used,remove hi limit...

    One tip I have used,remove hi limit switch,Install there to get before AC coil.
  7. I think the "guest" is referring to pulling...

    I think the "guest" is referring to pulling refrigerant back into the comp. Not pulling a vacuum before "setting" proper charge. My question,why are you doing this on "new' units?
  8. Replies
    13
    Views
    644

    Very good. Was there a piston attached to the...

    Very good. Was there a piston attached to the condenser? Thats the one to use,if not,double check charts.quessing about a .055.
    Pressure look pretty good to me,
  9. Replies
    16
    Views
    632

    I believe the E.R. uses liquid cocaine to re...

    I believe the E.R. uses liquid cocaine to re leave pain. Obviously not available over the counter!
  10. How do you check the pressures with both service...

    How do you check the pressures with both service ports closed?
  11. Replies
    6
    Views
    510

    And why didnt you try to warranty it? seems like...

    And why didnt you try to warranty it? seems like alot of work. We all know who's going to eat that!
  12. Replies
    5
    Views
    795

    Was out on routine service.Goodman GMS,this is...

    Was out on routine service.Goodman GMS,this is single stage nat gas,hi eff. (sorry no Mod&Ser). First thing I noticed was,plate in front of burner brown in color,more burnt look than rust. Visually...
  13. Replies
    33
    Views
    2,052

    [QUOTE=Af7171;18116211]Tech who do side work can...

    [QUOTE=Af7171;18116211]Tech who do side work can do it a lot cheaper .they use the company truck and company stock . No overhead . It all profit .

    Your correct there! We had a large HVAC Co....
  14. Replies
    33
    Views
    2,052

    A very prosperous salesmen once told me,If your...

    A very prosperous salesmen once told me,If your getting every job you bid,add 20%.,If work slows down,adjust accordingly!
  15. Replies
    22
    Views
    1,429

    Did I miss something?

    Did I miss something?
  16. Replies
    44
    Views
    13,484

    The "cleaning" property's of R410A are so much...

    The "cleaning" property's of R410A are so much better than say R22,. Been told by Reps. if you cut lines open down the road,there crystal clean! You know where it went?
  17. Replies
    19
    Views
    847

    Tip; Remove hi limit switch,take supply reading...

    Tip; Remove hi limit switch,take supply reading there.also take heat rise temp test.
  18. Replies
    14
    Views
    1,563

    Ditto; Goodman made a good move there!

    Ditto; Goodman made a good move there!
  19. Replies
    2
    Views
    356

    SALON...,have been told,chemical used in these...

    SALON...,have been told,chemical used in these place raise havoc with H.X etc! Bet the mechanical room is used to store them. Did have roofers once push chimney cap down,almost completely shut....
  20. Replies
    5
    Views
    483

    Yes the pilot did appear to be high,however they...

    Yes the pilot did appear to be high,however they have a heatshield above it,and cover.(could you even adjust it?) I did run my camera in to burner access,up to first bend,no holes. I did do a heat...
  21. Replies
    5
    Views
    483

    HEIL HELP NEEDED !

    Have an older Heil,condensating furnace. Msd NTGM100EHA3 Ser. L983817999 It keeps tripping roll-out switch,which I have replaced,that is attached to the closed combustion burner box.Box does appear...
  22. Replies
    29
    Views
    1,796

    Hows that work with "stand pipes" in cyl. tanks?

    Hows that work with "stand pipes" in cyl. tanks?
  23. Replies
    27
    Views
    1,889

    Had this same problem after replacing HSI with a...

    Had this same problem after replacing HSI with a retro fit. Lost seal in combustion air box,swirling air would not allow to light. Resealed with silicone,worked fine. Original HSI should have been...
  24. Replies
    36
    Views
    1,498

    Dido's....,7 cracks,one of the clam shells was...

    Dido's....,7 cracks,one of the clam shells was completely rusted off at face plate. Customer said the "click-it" switch was bad,he bypassed it. Was a roll-out switch. Cant fix stupid!
  25. Replies
    9
    Views
    996

    Traps can fool ya,by the time you get there,a...

    Traps can fool ya,by the time you get there,a partial blockage in trap will drain down. Will work fine when you reset the lock out.,then starts backing up water later when you've left. Clean em!