  1. One was a install i did 3 months ago it ran 30...

    One was a install i did 3 months ago it ran 30 min and no leak to be found
  2. Lennox elite water spots at bottom of inducer

    In the past week i have seen 2 lennox el195 and 1 ml193 furnaces with obvious water spots under the exhaust connection to the left of the inducer the panel between the burner comparment and blower...
  3. Thread: Home advisor

    by splus
    Replies
    8
    Views
    645

    I tell all those talking monkeys that call me me...

    I tell all those talking monkeys that call me me i will sign up and give them 20 percent of every completed and paid job that they can verify with the customer,the call usually ends pretty quick...
  4. Thread: skuttle 216-1

    by splus
    Replies
    2
    Views
    236

    inspector wants one installed in the basement in...

    inspector wants one installed in the basement in the event it goes negitive,i do remember seeing the 216 installed in a tee near floor level not sure if this is done anymore.all equipment is high eff...
  5. Thread: skuttle 216-1

    by splus
    Replies
    2
    Views
    236

    skuttle 216-1

    I need to install a make up air unit in a basement is the skuttle 216-1 still used.I remember seeing them installed with a 6" tee at floor level is this still done?
  6. Replies
    3
    Views
    400

    All the time,startup it makes no noise but just...

    All the time,startup it makes no noise but just before the blower stops when powered down it makes the noise
  7. Replies
    3
    Views
    400

    Lennox el195 blower moan

    EL195-90 lennox i started up on a new home today,all was well until the blower powered down there is a moaning noise.i have heard this on a few of these but not this loud and i did remove the...
  8. Thread: Best vaccum pump

    by splus
    Replies
    59
    Views
    4,367

    Get yourself a BBH= BIG BLACK HOSE,IT DRIVES ME...

    Get yourself a BBH= BIG BLACK HOSE,IT DRIVES ME NUTS WHEN TECHS GOT A YELLOW HOSE ON THE PUMP
  9. Replies
    7
    Views
    649

    the bottom of the Coil was frozen solid on both...

    the bottom of the Coil was frozen solid on both sides with a little bit of ice on the top middle of the coil didn't have any
  10. Replies
    7
    Views
    649

    Its 6 year's old,I am betting low charge but then...

    Its 6 year's old,I am betting low charge but then I need to find the leak
  11. Replies
    7
    Views
    649

    FROZEN COIL QUESTION

    Get to a call where the customer tells me its cooling but not like it should be,i get to the outdoor unit which is running with not alot of heat expelled from the fan.Before i coud get my guages on...
  12. Replies
    6
    Views
    462

    Good point using the coupling I guess i will get...

    Good point using the coupling I guess i will get some also
  13. Replies
    6
    Views
    462

    Nordyne txv valve with brazed equi.line

    Nordyne 669556 txv valve has a brazed in equalizer line its r22 5 ton i have alot of these out there and wanted a txv valve on the truck.do you unbraze the one thats there and attach the new...
  14. Replies
    7
    Views
    659

    This model down not have it.I'm not quite...

    This model down not have it.I'm not quite understanding why the blower works in heating mode but nothing else
  15. Replies
    7
    Views
    659

    Not sure what you mean by model plug,both the...

    Not sure what you mean by model plug,both the control and the blower board have been changed.i did talk to the owner of another company who told me about a white sticker on the blower board.any way i...
  16. Replies
    7
    Views
    659

    ICP H9MVX BLOWER ISSUE

    When i arrive at the call the furnace led was blinking normal standby code,on a call for heat nothing would happen even after bybass the stat.Both boards were replaced as the blower board had some...
  17. Replies
    20
    Views
    1,592

    Well i am starting this replacement tommorow and...

    Well i am starting this replacement tommorow and after a talk with the homeowner i am running a new line set inside a speedi channel cover on the outside of the house.
  18. Replies
    20
    Views
    1,592

    line set buried in the wall

    Doing a whole replacement attic system where line set replacement is not possible its inside the wall.while removing the old system i notice it was not BRAZED but soldered.I am thinking about putting...
  19. Replies
    1
    Views
    266

    LENNOX VENTING QUESTON

    The venting chart on the e195 furnaces only gives the footage for pipe with the number of 90 degree elbows.Is it correct that two 45 degree elbows equal one 90 degree elbow?
  20. Replies
    1
    Views
    230

    I always use a good air scoop and never have any...

    I always use a good air scoop and never have any issues.
  21. Replies
    0
    Views
    248

    EMI MINI SPLIT ISSUE

    Mod #zha2400 heat pump model,customer tells me the outdoor fan never shuts off.Put in high cool mode suction is 120psi and cooling well shut system of and outdoor fan never shuts off so i take the...
  22. Replies
    2
    Views
    416

    Going there in the am to check it out,it sounds...

    Going there in the am to check it out,it sounds like its coming from the back of the heat exchanger but thats just me
  23. Replies
    15
    Views
    2,011

    Service is up a tad and thats it,had 2 customers...

    Service is up a tad and thats it,had 2 customers this week decide to buy there parts online not sure if they called back as there number is now blocked.The only furnace changeout i did was 3 weeks...
  24. Replies
    2
    Views
    416

    Lennox el195 clicking sound

    Lennox el195 installed 2 weeks ago and the customer can hear a clicking sound coming from the inducer and from the vent pipe outside.I have always heard a faint sound from all of these but run with...
  25. Replies
    20
    Views
    2,627

    it's vented with 2 inch 35 feet total with...

    it's vented with 2 inch 35 feet total with fittings I went there today made sure there was enough pitchback on the vent pipe also thinking if there was built up water when the inducer shut off any...
  26. Replies
    20
    Views
    2,627

    i am going there in the morning to see what i find

    i am going there in the morning to see what i find
  27. Replies
    20
    Views
    2,627

    No water in collector box.I pull inducer and...

    No water in collector box.I pull inducer and drain it it did this a week ago and I checked it 3 days ago and everything seemed to be draining fine I could not hear any water in inducer
  28. Replies
    20
    Views
    2,627

    Flu is pitched with no standing water in...

    Flu is pitched with no standing water in pipe,might locate trap at collector box it runs for a week that has me stumped
  29. Replies
    20
    Views
    2,627

    Lennox el296v drainage issue

    I have a el296070 furnace that runs fine for 2 weeks and then the inducer fills with water and shuts the unit down.The trap is not installed at the collector its at the rear of the furnace about 30"...
  30. Replies
    1
    Views
    421

    Coleman roof jack question

    I am changing a coleman model number 4084a656 to an updated model number dgaa075bdtb and need to know if the roof jack jacks are compatible?The one thats there is in great shape and changing it is...
  31. Replies
    2
    Views
    486

    Lennox vent termination kits

    Anyone using the diversitech hvent2 or hvent3 for vent terminations?There half the cost of the lennox ones.
  32. Replies
    5
    Views
    787

    ICP pressure switch issue

    Icp mod n8npm050b from 2006,the burner lights for 20 seconds and goes out.Flame sensor was good check pressure switch operation which closes at -.58 and goes to .-64 but when the burner lights it...
  33. Replies
    7
    Views
    719

    I will do that Jeep Sent from my Torque using...

    I will do that Jeep

    Sent from my Torque using Tapatalk
  34. Replies
    7
    Views
    719

    Thanks dawg i updated my profile and sent you a...

    Thanks dawg i updated my profile and sent you a message also
  35. Replies
    7
    Views
    719

    LG LS090CE MINI SPLIT

    Does anyone have a troubleshooting guide or parts manual for this mini-split,the comp starts but the condensing unit fan motor never starts and the system shuts down in a few min.
  36. Replies
    3
    Views
    542

    Subcool reading was taken at the condenser ...

    Subcool reading was taken at the condenser

    Sent from my Torque using Tapatalk
  37. Replies
    3
    Views
    542

    76 degrees Sent from my Torque using Tapatalk

    76 degrees

    Sent from my Torque using Tapatalk
  38. Replies
    3
    Views
    542

    H/V CHARGING ISSUE

    New system startup 2.5 ton r-410 h/v system readings are,s/h=12,s/c=3 12 deg d/t, low side 118psi,high side 195 psi.The first floor is a walkout basement temp was 70 deg second floor 75 deg both have...
  39. Baldies got it right there I've had four leakers...

    Baldies got it right there I've had four leakers all c6 miles to the three years old

    Sent from my Torque using Tapatalk
  40. Thread: run cap question

    by splus
    Replies
    51
    Views
    6,235

    I would change it to the right one for sure what...

    I would change it to the right one for sure what will it harm the motor having the bigger one on there

    Sent from my Torque using Tapatalk
  41. Thread: run cap question

    by splus
    Replies
    51
    Views
    6,235

    run cap question

    Was on a call where there was a 7.5 cap on a motor that called for a 5mfd cap,was installed 2 years ago and running fine.Will this be okay if left like this?
  42. My company WAS installing nordyne equipment for...

    My company WAS installing nordyne equipment for 15 yearswith no issues until the microchannel systems came out.Most leakers dont show up until the second year and trying to find them have been not...
  43. Replies
    2
    Views
    458

    Thanks dawg Sent from my Torque using Tapatalk

    Thanks dawg

    Sent from my Torque using Tapatalk
  44. Replies
    2
    Views
    458

    Lennox c33 liquid line stub

    Is the 3/8od liquid line stub available as a part if so i need a part number,also the one that comes with the coil has a teflon o-ring on it do i need to install the o-ring that comes inside the coil...
  45. Replies
    2
    Views
    440

    So a standard 2.5 ring will work if OEM is larger...

    So a standard 2.5 ring will work if OEM is larger

    Sent from my Torque using Tapatalk
  46. Replies
    2
    Views
    440

    Trane blower motor question

    Trane part number moto4717 3/4 hp motor,need to know if a standard motor with 2.5 inch resilient rings will work I seem to remember some of these have 2/5/8 rings
  47. Replies
    12
    Views
    1,245

    The chimney has a tile liner in it now its been...

    The chimney has a tile liner in it now its been running fine for 2 days now told the customer we need to evaluate the chimney and possibly put a alum liner in it

    Sent from my Torque using Tapatalk
  48. Replies
    12
    Views
    1,245

    The chimney is on the outside of the house and we...

    The chimney is on the outside of the house and we have had a week off record cold here below zero wind chill

    Sent from my Torque using Tapatalk
  49. Replies
    12
    Views
    1,245

    Yes it will vent fine no spillage at the water...

    Yes it will vent fine no spillage at the water heater I haven't taken any draft reading yet its been venting and the boiler and then cycling for 24 hours

    Sent from my Torque using Tapatalk
  50. Replies
    12
    Views
    1,245

    After pulling the vent pipe off of the vent...

    After pulling the vent pipe off of the vent damper of the boiler letting it bent into the basement for a minute putting the vent pipe back on the damper in its been venting fine

    Sent from my...
Results 1 to 50 of 531
Page 1 of 11 1 2 3 4