  1. Replies
    33
    Views
    6,741

    not sure how to start a new thread

    comp2 on this trane unit shares cond. coil from circuit 1 just bottom 5 loops maybe 3 quare feet. And i know equal surfaces but didnt have a choice. need it running you do what you do. I can see the...
  2. Replies
    33
    Views
    6,741

    ycd120

    i have a restrition in number 2 circuit but it runs into number one circuit for about 5 loops why did they do that? anyhow had to get out for the day so i skip over the 5 loops and left 250 head 50...
  3. Replies
    41
    Views
    6,525

    voyager

    well the way i see it if they put a crap system together and sell it top dollar then i dont care if it is 5 years outta warranty. One way or another im going to protect my customers and i did and i...
  4. Replies
    41
    Views
    6,525

    the kit

    just a new wiring harness and a contactor basicly pull lo heat hi heat and cbm to right of high heat pull y1 y2 on transformer and get rid of the4 wiring harrness and the molex to the to the cfm ....
  5. so like i was saying

    3 min is a good valid harvest when u hear the crack u can hear the hotgass open pressure rise is fast. with a manotowic pressure needs to get over 50 for at full harvest. so if half the plate drops...
  6. Replies
    13
    Views
    1,583

    media filters

    any one will do. If your after looks then maybe its time to see a shrink about the anal disorder. fa real get the one that best fits ur existing ductwork... and can handle the cfm``sss
  7. so does

    this sound like a good ANSWER. There could b seperations on solder joints but if u got a hot gas valves being 2 u can feel them at harvest if u place ur hand right after the valves and it gets...
  8. Replies
    10
    Views
    1,121

    these are questions for a ductman so i thinks ur...

    these are questions for a ductman so i thinks ur allset
  9. sounds like a hot gas valve failing to open. does...

    sounds like a hot gas valve failing to open. does it have 2 hot gas vlaves? Anyhow thats where i would start if the pressures are there. Ask wat pressures shoul;d b at harvest if they dont get high...
  10. Replies
    6
    Views
    1,071

    did it again

    sorry again =
  11. Replies
    41
    Views
    6,525

    kits

    kits are for 12.5 to 50 ton. They come in a seperate box, And if you don`t install it those motors u put in will dieeeeee. Cant stop a trane.... And ya cant stop a fasco inducer motor either...... ...
  12. Replies
    14
    Views
    2,273

    sorry bout that

    i am new and it won`t happen again. Just like to help peeps
  13. Replies
    6
    Views
    1,071

    ptaks

    i have 300 of them if i throw away it will cost me a 180k. takes ten min to fix anyh part on them
  14. Replies
    46
    Views
    7,606

    this system

    looks like a homeowner was saving dough. Far as pic 8 i just think u do wat ya have to do when ya dont have pipe cutters...:beat::beat:
  15. Replies
    14
    Views
    2,273

    108 6 inch, 132 6 or 7 inch, 50 if it inside bath...

    108 6 inch, 132 6 or 7 inch, 50 if it inside bath meaning no outside walls dont bother with it. living room 8 inch, kitchen 7 inch. all boots can b 10x4 , 8 inch even 10x6 ...
    If you have a lil...
  16. Replies
    6
    Views
    1,071

    check ur wiring. I need more info to help.You...

    check ur wiring. I need more info to help.You have a tstat loacted on a wall? And it has power other then a battery. unplug the tstat at the unit and run it without. If you have a ptac with out a...
  17. Replies
    22
    Views
    4,245

    these units are quirky. during pm tighten all...

    these units are quirky. during pm tighten all test board screws they come loose and will stop calls. If when u reset the unit it works good then u tripped out on temp.. Check to see proper ducting...
  18. Replies
    41
    Views
    6,525

    not the motors

    its the design and they changed it with a new wiring harness and a contactor. This way there is no power at the cfm until a heat call is introduced/...
  19. Replies
    41
    Views
    6,525

    cfm

    dont just replace the cfm it will happen again like u said. You need the kit to rewire it. they will supply it free. this issue also kills ignitors and can kill gas valves... the kit tankes ten...
  20. Replies
    7
    Views
    1,600

    i have starting having the same issue with the...

    i have starting having the same issue with the ignitors an trane charged me 80 bucks for 1. The ignitor is the smallest issue i have with the unit. Finally got them to fork over a kit for the...
  21. just saying

    hydro air is a waste of time. If you must know what to do for hydro air buy a hot water coil and cut it itno the duct and get a nice airjhanlder and wire it accordingly.... keep it simple first...
  22. Replies
    14
    Views
    2,379

    tricky riellos

    This burner is nice after you set it up properly. I have seen countless riello issues. I saw someone used a smaller nozzle and tweaked it. If you use a smaller nozzle then you set it for riellos...
  23. hydro air

    why hydro air? Does everyone really think it will help with dry air. It doesn`t do anything but add extra trouble down the line. Best heat is radiant or baseboard.
Results 1 to 23 of 23