    are there other air handlers with secondary loops...

    are there other air handlers with secondary loops ? may be pumps were changed and one pump is over powering another. or maybe as simple as a clogged strainer good luck
  2. Thread: trane rtu

    by cool frog
    Replies
    6
    Views
    755

    the only thing i could think of is to blow nitro...

    the only thing i could think of is to blow nitro into evap coil from suction line to try to clear the restricted orfice-good luck
  3. Replies
    33
    Views
    4,370

    by front seating the suction service valve that...

    by front seating the suction service valve that compressor should be able to pump down to about 20 inch. vac. on the suction side of the compressor regardless of what charge is in the unit. if it...
  4. Thread: UA STAR

    by cool frog
    Replies
    24
    Views
    3,196

    local 475- New Jersey my company...

    local 475- New Jersey

    my company had us take the nate test a few years ago and i found it pretty easy. Now they are pushing the star test. We took it in october and only 50% of the...
  5. Replies
    4
    Views
    827

    i think a friend of mine has one of these systems...

    i think a friend of mine has one of these systems in his house that was built in 1920. the compression tank is in the attic and is open through the roof . its nothing more than a storage tank for...
  6. Replies
    26
    Views
    2,201

    cut out the old shaft ,cut the new one in...

    cut out the old shaft ,cut the new one in workable lengths and use shaft couplers. just make sure that all is lined up perfect- mcmaster sells a whole array of shaft couplers. good luck
  7. Replies
    3
    Views
    943

    and one is in a vacuum and one isn't

    and one is in a vacuum and one isn't
  8. Replies
    11
    Views
    967

    monsen is a good company to work for-low stress

    monsen is a good company to work for-low stress
  9. Replies
    65
    Views
    58,976

    stay bright solder has about the same strenght as...

    stay bright solder has about the same strenght as a brazing alloy that has 5% silver.
    as for the flux goes if it is for refrigeration/air conditioning work it should have "no" acid.
    when i...
  10. Replies
    9
    Views
    857

    you will still be able to buy r22 long after they...

    you will still be able to buy r22 long after they stop making it, i work on large chillers and they stopped making r11 about ten years ago and they have such a stock pile of r11 from all the...
  11. Replies
    13
    Views
    2,153

    no problem fixerup. i had 5 compressors with bad...

    no problem fixerup. i had 5 compressors with bad check valves in them. it took me a while to figure it out.
    remember if you have low discharge super heat than your suction superheat must be low...
  12. Replies
    13
    Views
    2,153

    TO FIXERUP if you have bad discharge...

    TO FIXERUP
    if you have bad discharge check valves is that on the off cycle like overnight your refrigerant will/can migrate from your condenser through your compressor and over fill your...
  13. Replies
    156
    Views
    17,438

    local 475, NEW JERSEY

    local 475, NEW JERSEY
  14. Replies
    13
    Views
    2,153

    if these are the carrier screws that i think they...

    if these are the carrier screws that i think they are then i would check my discharge check valve
  15. hey guys, just got back from training on these...

    hey guys, just got back from training on these compressors up in canada. i'm also a little leary to new technolegy but these are pretty bullet proof. on board computer controls bearings and inlet...
  16. Replies
    91
    Views
    32,503

    hey guys, i had the same problem with a smaller...

    hey guys, i had the same problem with a smaller flowtronic and it was caused by the unit not configuered properly. my unit was configuered for txv's when it should have been for exv's. did you go...
  17. Replies
    16
    Views
    4,318

    if you had a restriction your superheat would be...

    if you had a restriction your superheat would be high.
    also,when troubleshooting never take anything for granted.
    you might have to look at the duct system for restrictions.

    youcould have a...
  18. Replies
    49
    Views
    3,704

    double bubble asked the first right question,what...

    double bubble asked the first right question,what type of chiller is this?
    a recip compressor doesn't know or care what type of condenser it has, just as long as it is sized properly....
  19. Replies
    11
    Views
    2,101

    that oil is big bucks to

    that oil is big bucks to
  20. Replies
    5
    Views
    804

    i got the clog in the low temp heat exchanger...

    i got the clog in the low temp heat exchanger broken up. now its just trimming the charge
  21. Replies
    11
    Views
    2,101

    it depends if you have the optional sution...

    it depends if you have the optional sution buterfly type service valve. if you do, just recover everything into the condenser and look for that nice big service valve on the bottom of the oil...
  22. Replies
    3
    Views
    2,362

    buy a wet bulb indicator. they never go out of...

    buy a wet bulb indicator. they never go out of calibration and they either work or they don't because of broken glass. somebody put a posting a couple of months ago and i can't remember the brand...
  23. Replies
    4
    Views
    675

    also if you have a mixing or tempering valve i...

    also if you have a mixing or tempering valve i would look at that if it had worked in the past. mineral deposits have a tendency to clogg these up
  24. Replies
    5
    Views
    804

    thanks for the advise r718. 1- as...

    thanks for the advise r718.
    1- as for the 140 deg. i'm pretty sure its because of internal overloads on solution pump.

    2- i had to have the high temp...
  25. Replies
    5
    Views
    804

    i have a carrier 16jt 500 tons(mexico vintage)...

    i have a carrier 16jt 500 tons(mexico vintage) that my cutomer locked up on me. after having hi-temp generator retubed and getting the machine up and running my boss sends me there on a friday night...
  26. Thread: York EZ Zone

    by cool frog
    Replies
    3
    Views
    1,066

    i would try there web site. sometimes you can get...

    i would try there web site. sometimes you can get info online that they tell you is not available.
  27. Replies
    23
    Views
    2,513

    yea, ihad a small nick in my hand get infected...

    yea, ihad a small nick in my hand get infected real bad. whole hand swelled up
  28. Thread: C3 & C4 oils

    by cool frog
    Replies
    3
    Views
    673

    you don't have to worry about wax build up. c4...

    you don't have to worry about wax build up. c4 oil is the same as 4gs oil and national 300. it is a 300 weight oil as apossed to c3 being a 150 weight oil.
  29. Replies
    3
    Views
    1,458

    system was designed for NH3 but before start up...

    system was designed for NH3 but before start up was converted to r22. same type of system though
  30. Replies
    18
    Views
    1,516

    besides, every tower manufactuer will also tell...

    besides, every tower manufactuer will also tell you to do it this way
  31. Replies
    18
    Views
    1,516

    to keep mineral build up from forming on tubes...

    to keep mineral build up from forming on tubes you want pump to always run before fan starts and fan to shut off before pump shuts off. if this doesn't sound so important to you i can tell you of an...
  32. Replies
    11
    Views
    1,518

    the purpose of the power head assy. on the txv is...

    the purpose of the power head assy. on the txv is to sense leaving evap. refigerant temp,thus always trying to maintane a steady superheat . this is what makes a txv differant from an automatic...
  33. Replies
    3
    Views
    1,458

    i had a verry strange service call the other day....

    i had a verry strange service call the other day. i was called up because this fes m/n 19L compressor was shut down for no oil in either sight glass.the operaters had shut it down and started up the...
  34. Replies
    0
    Views
    694

    i had a verry strange service call the other day....

    i had a verry strange service call the other day. i was called up because this fes m/n 19L compressor was shut down for no oil in either sight glass.the operaters had shut it down and started up the...
  35. Replies
    5
    Views
    837

    student2817 are you asking in general or are you...

    student2817 are you asking in general or are you refering to a specific type of system? jeffflk is refering to a large system with probly screw compressors. there are small chillers that use nh3 as...
  36. during building of the hoover or boulder dam,what...

    during building of the hoover or boulder dam,what ever they bcall it these days. they ran piping into the concrete as they poured it to speed up the curing process.carrier designed these chillers....
  37. Replies
    2
    Views
    980

    i've only read about steam jet cooling. so with...

    i've only read about steam jet cooling. so with that said i'll give my opinions for what there worth. the pros are i would think is ease of operation-little or no moving parts. and if waste steam...
  38. Replies
    9
    Views
    1,528

    100 ppm

    100 ppm
  39. Replies
    8
    Views
    2,348

    as your suction pressure goes up keep an eye on...

    as your suction pressure goes up keep an eye on your slide valve indicator rod. if you have a bad ring on your slide valve it will release hydrolic pressure and if i remember right you should start...
  40. Replies
    7
    Views
    1,062

    what i did was install a cold trap before the...

    what i did was install a cold trap before the vacuum pump to keep oil fresh without opening balast. then i set leak detector in sniffer mode and conected a hose to the outlet of vacuum pump and...
  41. Replies
    7
    Views
    1,062

    well, i found the leak. i used shaving cream. my...

    well, i found the leak. i used shaving cream. my shop had sent down a "gun" used to pressurize each tube but was unable to use it. so what i did was pressurized the machine and filled the end of each...
  42. Replies
    27
    Views
    3,278

    if i had to work on a low pressure machine i...

    if i had to work on a low pressure machine i would prefer r-11. your not supposed to inhale r-123 or get any oil on your skin. some guys and companys don't follow these saftey guide lines and it...
  43. Replies
    7
    Views
    1,062

    i have a carrier 16jt absorber. i'm doing a...

    i have a carrier 16jt absorber. i'm doing a vacuum leak check with helium. found one of the leaks in high temp generator. now i must determine if its in the tubes (steam) or tube sheet. any...
  44. Replies
    11
    Views
    1,010

    if i know what your talking about it has 1 puge...

    if i know what your talking about it has 1 puge eductor.the operators normaly get enough air out of the machine to keep it running
  45. Replies
    11
    Views
    1,010

    i'v evacuated with pump doing a bubble count.i...

    i'v evacuated with pump doing a bubble count.i can get it down to no bubbles and it will be good for a while. one mistake i made was to change a diaphram valve on absorber section that was split on...
  46. Replies
    11
    Views
    1,010

    m/n-16jt854-36495

    m/n-16jt854-36495
  47. Replies
    11
    Views
    1,010

    this machine runs at 125 psi steam

    this machine runs at 125 psi steam
  48. Replies
    11
    Views
    1,010

    i also had cycle gaurd activated due to high ref....

    i also had cycle gaurd activated due to high ref. levell. i pulled noncondensables from absorber section (air) and my ref. levell went back to normal-thanks again
  49. Replies
    11
    Views
    1,010

    helium test

    the machine is a 16jt if that makes any difference as far as leaks go.this machine is in central jersey.thanks for all the great info.

    how would you helium leak check the...
  50. Replies
    11
    Views
    1,010

    hope your solution was a bright yellow and not...

    hope your solution was a bright yellow and not clear as you described it. Did you leak test the generator bundle? Its not rolled in like other machines.