  1. Replies
    30
    Views
    1,848

    purchased the Supco 3-wire hard start kit Friday,...

    purchased the Supco 3-wire hard start kit Friday, less expensive than the 521, appears to be built with quality. United pt# 3W3, never tried them, but will see if it performs as well as the 521.
  2. Thread: RTAA

    by mkitrtfst
    Replies
    5
    Views
    943

    Thanks joey!Will confirm in mrning.

    Thanks joey!Will confirm in mrning.
  3. Thread: RTAA

    by mkitrtfst
    Replies
    5
    Views
    943

    uo3k02828

    uo3k02828
  4. Thread: RTAA

    by mkitrtfst
    Replies
    5
    Views
    943

    rtaa1254xq01a3c0bfg/ latch fault on EXV failure....

    rtaa1254xq01a3c0bfg/ latch fault on EXV failure. Test drives o.k.,have older service lit. showing different wire color for terminal plug. Has this changed? Ohm value not the same either.Any help...
  5. Replies
    11
    Views
    806

    Good Luck workhorse! I am just venting....

    Good Luck workhorse! I am just venting. appreciate your input.
  6. Replies
    11
    Views
    806

    This has been my home for all my life and have...

    This has been my home for all my life and have been in the trade for over 28years. I have been on jobs near the gulf coast where underground wiring sits in flooded conduit that is as old as the...
  7. Replies
    11
    Views
    806

    If others have experienced storm damage anywhere...

    If others have experienced storm damage anywhere from water, what was they required to do in order for services repowered?
  8. Replies
    11
    Views
    806

    looking at this in a larger picture,the reality...

    looking at this in a larger picture,the reality of every business or home having to be reworked. We are not coming back in any near future. I ask if there was a fear of wiring failure can a ground...
  9. Replies
    11
    Views
    806

    They are requiring all romex to be...

    They are requiring all romex to be replaced,claiming the paper wicking the water into its jacket and cauing failure from corrosion. I believe contactors, alluminum connections,micro switches, etc.is...
  10. Replies
    11
    Views
    806

    Asking for input on our city "safty and permits"...

    Asking for input on our city "safty and permits" demanding replacement of all electrical devices contacting water. This includes wiring.
  11. Replies
    9
    Views
    1,704

    If you convert to txv,would your cold control...

    If you convert to txv,would your cold control work correctly if it is a constant cut in?This is in referance to med. temp.
  12. Replies
    26
    Views
    2,300

    Good info,got to go to work.

    Good info,got to go to work.
  13. Replies
    26
    Views
    2,300

    Self, are you installing the cap without...

    Self, are you installing the cap without soldering the lines together?
  14. Replies
    26
    Views
    2,300

    I have had restricted cap tubes in the same...

    I have had restricted cap tubes in the same application. My questions, does the cap tube have to be soldered back on the suction line and is there a reason bev-air use .042id.X.093od.? That size only...
  15. Thread: AHU thru drs

    by mkitrtfst
    Replies
    0
    Views
    661

    I have a job with a bryant 515---240 in a...

    I have a job with a bryant 515---240 in a vertical application it is matched to a bryant 566B300. they want to replace it but I am having trouble finding something to fit. It is on the second floor,...
  16. Replies
    33
    Views
    4,760

    Man , I wish you were in our area! No consistency...

    Man , I wish you were in our area! No consistency on our automation.Be nice if there was some general agreement on simple controlling.
  17. Replies
    27
    Views
    3,067

    If in dought, install phase protector with...

    If in dought, install phase protector with capability of logging type of failure.ICM makes one around 120.00 bucks.control contactor with protector in series,use this set up as dianostics or leave it...
  18. Replies
    29
    Views
    3,354

    checked on equipment yesterday, no history of any...

    checked on equipment yesterday, no history of any shut downs, checked fans,confirmed sensor accuacy on sat. cond. Overfeeding exv,interesting thought,system load changes quickly,city water is used...
  19. Replies
    29
    Views
    3,354

    System stayed on line all day.Confirmed sat. cnd...

    System stayed on line all day.Confirmed sat. cnd temp.accuracy, oil sensor accuracy, start up normal,did not check fans. INTERMITENT SAT. COND. sensor probably is the culprit. If to many fans are on,...
  20. Replies
    29
    Views
    3,354

    Trying to get there this morning.

    Trying to get there this morning.
  21. Replies
    29
    Views
    3,354

    rained all day,sent me on another location,to...

    rained all day,sent me on another location,to answer questions on last post. This unit uses the UCP sensor inputs of sat. cond temp.and oil temp. OILtemp. cannot fall any lower than 4 degrees of sat....
  22. Replies
    29
    Views
    3,354

    I tell ya. This has been frustrating, new...

    I tell ya. This has been frustrating, new cuttler/hammer contactor on replacement compressor is faulty,spring to hold coil away from contactor is installed sideways, compressor shuts down on single...
  23. Replies
    29
    Views
    3,354

    Thanks,will do just that in morning,confidence...

    Thanks,will do just that in morning,confidence gets low when it everything looks right.
  24. Replies
    29
    Views
    3,354

    Put my fluke clamp on temp.sensor on oil inlet at...

    Put my fluke clamp on temp.sensor on oil inlet at compressor.Sensors are showing same. Checked condensor pressure to sat. temp. check ok.
  25. Replies
    29
    Views
    3,354

    this unit uses diff of sat.cond. temp. to oil...

    this unit uses diff of sat.cond. temp. to oil temp at the compresor in processor for safty shut down.
  26. Replies
    29
    Views
    3,354

    Called out on alarm for compressor replaced...

    Called out on alarm for compressor replaced couple days ago. diagnostics tells shut down on "oil system fault". Checked pressure drop across oil filter, right on the chart for NORMAL line. watched...