Search:

Type: Posts; User: A1 Burt

Page 1 of 9 1 2 3 4

Search: Search took 0.01 seconds.

  1. Thread: Tor-Rey

    by A1 Burt
    Replies
    8
    Views
    226

    HAD TO CHANGE A CONDENSOR FAN MOTER NOT FUN

    HAD TO CHANGE A CONDENSOR FAN MOTER NOT FUN
  2. Replies
    1
    Views
    273

    ohm out fan cycling switch & low pressure for...

    ohm out fan cycling switch & low pressure for continuity & grounded
  3. Replies
    5
    Views
    355

    a liquid cooled condenser.

    a liquid cooled condenser.
  4. Replies
    16
    Views
    750

    AIR FLOW ?

    AIR FLOW ?
  5. Replies
    15
    Views
    782

    clean the water side of the machine then clean...

    clean the water side of the machine then clean the air side of machine it would be nice if I knew what type machine it is good luck
  6. mike . let one of your h-v-a-c guys build some...

    mike . let one of your h-v-a-c guys build some thing with you when you get back home .good luck.
  7. Thread: Adding R404a

    by A1 Burt
    Replies
    72
    Views
    3,450

    TROLL---TROLL---TROLL

    TROLL---TROLL---TROLL
  8. Thread: Adding R404a

    by A1 Burt
    Replies
    72
    Views
    3,450

    look at the liqed reciver find the sight glasses...

    look at the liqed reciver find the sight glasses should be maybe 4 or 5 bring leavel up to 1st or2nd sight glass then open some walk in cooler & frezer doorsleve them open for a little while maybe...
  9. Replies
    23
    Views
    2,642

    "THIRD WORLD"

    "THIRD WORLD"
  10. Replies
    2
    Views
    295

    since you took X- term off timer just reduce...

    since you took X- term off timer just reduce amount of time on each defrost . get the right fan delay - termator switch hook it up right put defrost time back to were it was . be done with the call .
  11. Replies
    14
    Views
    2,146

    the garden hose must be used for a drain line on...

    the garden hose must be used for a drain line on one of those hook up some where . it was there so lets use that old suction line we can save a lot of money .
  12. i take care of a 1200 modle and thay got it used...

    i take care of a 1200 modle and thay got it used frist thing i had to fix was t-x-v only one was bad but did both any way . about 5 years latter one went bad this time only changed one valve the...
  13. Replies
    52
    Views
    3,655

    this store has one that i think is a 1962 this is...

    this store has one that i think is a 1962 this is ser# w-62A-19067 that one is for a walk in it still has R-12 This other one is for a produce case G-62D-08436 both are 3 phase
  14. mike I had to see where you were from . I have a...

    mike I had to see where you were from . I have a diner with the same ding's I think they used a meat clever It is amazing the thing still drop's ice
  15. Thread: TXV adjustment

    by A1 Burt
    Replies
    17
    Views
    1,125

    temp control ? L.P.C. ? check them out

    temp control ? L.P.C. ? check them out
  16. superheat=temperture on suction line next to...

    superheat=temperture on suction line next to sencing bulb- then get a presure reading next to sencing bulb convert to temp from a pressure - temperature chart subtrack the two numbers then you will...
  17. Replies
    5
    Views
    491

    1938 frigidaire

    compressor had a lose wire on middle post tighten it up all good . happy camper
  18. Replies
    48
    Views
    4,994

    on simi hermetic where wire hook up to termanile...

    on simi hermetic where wire hook up to termanile post if you see oiley resadew in side when you take cover off there you go be careful when tightening up post!!!
  19. G-E used the stuff as a refrigerant for 18 months...

    G-E used the stuff as a refrigerant for 18 months then stoped methylformate was used in nerve gas .
  20. the C-A modle had METHYL FORMATE in them...

    the C-A modle had METHYL FORMATE in them bad stuff stay away !!!!!!!!!!!!
  21. Thread: Short Cycle

    by A1 Burt
    Replies
    21
    Views
    1,563

    power head on t-x-v ?

    power head on t-x-v ?
  22. Replies
    8
    Views
    2,012

    bradleyshermetics.com I got 3 of them & sight...

    bradleyshermetics.com I got 3 of them & sight glass & o rings & gaskets
  23. Thread: made in china

    by A1 Burt
    Replies
    4
    Views
    651

    bunny that is about right

    bunny that is about right
  24. Thread: made in china

    by A1 Burt
    Replies
    4
    Views
    651

    made in china

    are some manitowoc ice machines made in china ?
  25. Replies
    40
    Views
    4,157

    check hot gas valve for leek

    check hot gas valve for leek
Results 1 to 25 of 203
Page 1 of 9 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event