Search:

Type: Posts; User: furnacemaninc

Page 1 of 2 1 2

Search: Search took 0.00 seconds.

  1. Thread: Nest?

    by furnacemaninc
    Replies
    17
    Views
    842

    Honeywell knows HVAC Sent from my iPad...

    Honeywell knows HVAC


    Sent from my iPad using Tapatalk
  2. Replies
    11
    Views
    465

    I prefer spray glue, it stops them instantly and...

    I prefer spray glue, it stops them instantly and I get to pretend I'm spider man


    Sent from my iPad using Tapatalk
  3. Replies
    3
    Views
    162

    Nice burn :cheers:

    Nice burn :cheers:
  4. Replies
    3
    Views
    162

    User name

    Is there a way to change my user name?
  5. Replies
    9
    Views
    406

    Thanks for all the help, I'll give an update...

    Thanks for all the help, I'll give an update after the repair is completed
  6. Replies
    9
    Views
    406

    The check valve is piped in parallel with the...

    The check valve is piped in parallel with the outdoor coil txv, the indoor coil uses a fixed orfice, suction dryer was piped in between the compressor and the reversing valve, unit m# wsc120a4roa1
  7. Replies
    9
    Views
    406

    Heat pump pumping down

    I have a 10ton trane r22 rooftop heat pump package unit that has two five ton comps splitting the capacity. I replaced a burnt out compressor yesterday, new filter dryer added suction dryer, replaced...
  8. Replies
    4
    Views
    374

    When you replaced the txv did you change out the...

    When you replaced the txv did you change out the screen right before the valve?


    Sent from my iPad using Tapatalk
  9. 45 for copper 37 for stainless

    45 for copper
    37 for stainless
  10. Replies
    21
    Views
    1,093

    I always thought the 5' of flex was for t bar...

    I always thought the 5' of flex was for t bar register connection
  11. Replies
    6
    Views
    476

    Take care of that air flow problem, adjust the...

    Take care of that air flow problem, adjust the txv then dial in the charge.
  12. Replies
    9
    Views
    505

    Sounds just like one hour

    Sounds just like one hour
  13. Replies
    12
    Views
    2,202

    Is this unit direct or belt drive, if belt drive,...

    Is this unit direct or belt drive, if belt drive, follow low voltage wires over the top of the blower and check for chaffing. I have often seen the wires shorting on the 5/16 screw heads. Is the...
  14. Replies
    34
    Views
    5,491

    The Goodman guy is at it again…

    The Goodman guy is at it again…
  15. Replies
    8
    Views
    1,286

    if the transformer is set at 230 and power is...

    if the transformer is set at 230 and power is 208, you might need to change the setup
  16. Yes I tried closing one of the service valve,but...

    Yes I tried closing one of the service valve,but no luck, what if I have too much oilin the compressor? I was thinking about changing the comp oil at the same time as the valve.
  17. The valve would not switch out of the heating...

    The valve would not switch out of the heating position, when the coil was energized i could hear the pilot valve click, i
    I also confirmed the refrigerant charge was ok. Both valves and refrigerant...
  18. reversing valve trouble, heeeeeeeeeeeeeeeeeeelp!

    I have beeb working on a new EMI 3x multi heat pump. I replaced the reversing valve and operation to the unit was restored, the following month the same thing happens, once again the the valve was...
  19. Replies
    30
    Views
    3,867

    Get something with side clips instead of...

    Get something with side clips instead of Velcro,they will last much longer, gel is best, flat caps are good so they stay on your knees.
  20. Replies
    15
    Views
    1,353

    I had a hot tub pump do that and it ended up...

    I had a hot tub pump do that and it ended up being the outlet
  21. Replies
    36
    Views
    7,298

    DONT USE IT! I used it to try to help out an old...

    DONT USE IT! I used it to try to help out an old time custumer and it ended up seizing the compressor 3 months later
  22. Replies
    23
    Views
    4,552

    Then we clean the coil and watch the top of the...

    Then we clean the coil and watch the top of the compressor pop from all the freezone that was put in.
  23. Replies
    16
    Views
    3,290

    they really must have felt like welding something?

    they really must have felt like welding something?
  24. Replies
    9
    Views
    3,158

    thats needs to be in the hall of fame, those last...

    thats needs to be in the hall of fame, those last for ever! watch out for the A stuff..
  25. Replies
    23
    Views
    4,552

    did it ever have a filter?

    did it ever have a filter?
Results 1 to 25 of 48
Page 1 of 2 1 2
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event