Search:

Type: Posts; User: Zippy4god

Search: Search took 0.00 seconds.

  1. Replies
    12
    Views
    629

    80% phase out information

    Does anyone know where i can go to get info on where we are on the doe phase out of furnaces
  2. Replies
    18
    Views
    1,129

    the factory rep is the one who diagnosed the...

    the factory rep is the one who diagnosed the accumulator his thoughts are that in the accumulator there is a (injector) opening meant to force oil back to the comp and leave liquid in the accumulator...
  3. Replies
    18
    Views
    1,129

    bad factory accumulator causing system to keep...

    bad factory accumulator causing system to keep oil in accumulator and block ref flow to compressor
    thanks for all the feedback i really appreciate it
    glad there is a place to bounce ideas off...
  4. Replies
    18
    Views
    1,129

    i thought this is where advise could be found 26...

    i thought this is where advise could be found
    26 yrs in hvac senior nate, journeyman hydronics, hvac, plumbing, and elec in the state of iowa if credentials are needed
  5. Replies
    0
    Views
    169

    teledyne larrs boilers

    is the a way to clean teledyne lares boilers heat exchangers without tearing the top off and using a brush
    i've got one that has corrosion between the heat discs and is slowing the flue down to the...
  6. Replies
    10
    Views
    641

    flame sensors question

    i have a theory about flame sensors can anyone verify
    i have noticed in the past few years that is a clothes dryer is in the same room as the furnace and they use dryer sheets the life of the sensor...
  7. Replies
    18
    Views
    1,129

    HELP heat pump

    i'm working on a 3 month old york heat pump
    in heat mode the system will produce heat for a short time (60 seconds) then the suction line gets cold and the compressor sounds slightly stressed, this...
  8. Replies
    3
    Views
    265

    fasnseal piping

    i have a customer with the older style of fas n seal piping does anyone have any info on if this piping is under warranty
  9. Replies
    6
    Views
    377

    the city inspector said copper was ok less than...

    the city inspector said copper was ok
    less than 15 psi
  10. Replies
    6
    Views
    377

    steam boilers

    can the near boiler piping on a zero pressure boiler (residential) be piped in copper
  11. Replies
    14
    Views
    986

    residential steam boilers

    i'm looking for any tips on installing a steam boiler in a residence. specifically what the difference is between a single pipe and dual pipe system and anything i need to be aware of
    i've...
  12. Thread: old york

    by Zippy4god
    Replies
    7
    Views
    389

    upside down U shape with a dual shaft fan out...

    upside down U shape with a dual shaft fan out both sides
  13. Thread: old york

    by Zippy4god
    Replies
    7
    Views
    389

    it looks much older than either one of those

    it looks much older than either one of those
  14. Thread: old york

    by Zippy4god
    Replies
    7
    Views
    389

    old york

    can anyone tell me how old this york condenser is
    hice024a06a
    mglm107153
  15. Replies
    6
    Views
    515

    what i'm looking for is how to set up the dc...

    what i'm looking for is how to set up the dc voltage, so i don't have to have an open flame. guys get a little crazy sometimes around fire.
  16. Replies
    6
    Views
    515

    flame rectification

    I know we are coming to the end of heating season, but considering it will be back before we know it. I am wanting to build a test/trainer for my shop, can anyone tell me how to prove flame without...
  17. Replies
    10
    Views
    725

    Just Remember that there will always be something...

    Just Remember that there will always be something for you to learn. Keep searching for new things. Even those of us who have been doing this for a long time have things to learn. like how to setup an...
  18. Replies
    6
    Views
    541

    flame rectification help

    I could use some help understanding flame rectification. I've done some research online and have a decent understanding how it works when there is a separate ignitor and flame sensor. My challenge...
  19. Replies
    73
    Views
    11,191

    Static pressure testing

    Just wondering how many techs check static pressures on systems in the homes we are servicing.
    How important is it?
  20. Replies
    20
    Views
    2,235

    Hard start kits

    Im looking for opinions on hard start kits for compressor are they benificial or not. I have heard Copland recommends them can anyone give me a place to go to get written verification of this.
  21. Thread: Nate senior

    by Zippy4god
    Replies
    34
    Views
    3,712

    Passed Nate senior!!!

    Passed Nate senior!!!
  22. Thread: Airtime 500

    by Zippy4god
    Replies
    1
    Views
    948

    Airtime 500

    Looking for an opinion on airtime 500 companies and their practices
  23. Thread: Nate senior

    by Zippy4god
    Replies
    34
    Views
    3,712

    The last in the series of Nate exams.

    The last in the series of Nate exams.
  24. Thread: Nate senior

    by Zippy4god
    Replies
    34
    Views
    3,712

    Nate senior

    Any study tips on Nate senior exam taking it Monday.
  25. Replies
    9
    Views
    809

    Education help

    I have been installing and servicing since 88. I learned from the school of hard knocks,I'm looking for a good place to get book knowledge. Suggestions?
Results 1 to 25 of 25