Search:

Type: Posts; User: hvac_czar

Page 1 of 20 1 2 3 4

Search: Search took 0.03 seconds.

  1. Absolutely... Way back in the day all we got was...

    Absolutely... Way back in the day all we got was "Here's your beeper, make it happen"... I spent many a terrified early morning hour alone in a boiler room, that is not the goal with our greenhorns...
  2. Thanks Coolwhip, True about the streets! All...

    Thanks Coolwhip,

    True about the streets! All of them old cow paths!

    Still looking for the right tech...

    Lots of kids here go to "for profit" tech schools (ITT Tech, etc.) and find on...
  3. "is boston expensive place to live? it seems to...

    "is boston expensive place to live? it seems to be an expensive place to live being historic and university town and such? I've been there in the summer, it's jammed pack with tourists."



    ...
  4. Got to have a little humor!

    Got to have a little humor!
  5. If you do, look me up... Will be our busiest...

    If you do, look me up... Will be our busiest Winter ever on the construction side and service always follows construction here.
  6. Thanks fellas... The trades have been awesome for...

    Thanks fellas... The trades have been awesome for me, I know the trades are still an awesome career choice... I guess the times have changed.
  7. Where have all the techs gone? I have added 2...

    Where have all the techs gone? I have added 2 service techs in the last 6 months and with the department growing I need another but the pool of qualified applicants just is not there. We have tried...
  8. Commercial Service Tech Needed- Boston Metro

    Hi Fellas,

    One of New Englandís largest Mechanical Contractors is seeking a seasoned commercial service tech to join our growing HVAC Service Department. Must be experienced and currently working...
  9. Replies
    12
    Views
    915

    Might want to save a copy of the station...

    Might want to save a copy of the station *unedited* too... just in case "something bad" happens!
  10. I'll have 2 available if you can wait a couple...

    I'll have 2 available if you can wait a couple weeks.
  11. Thread: FX40 stuff

    by hvac_czar
    Replies
    12
    Views
    931

    So, for someone still somewhat new to the FX40...

    So, for someone still somewhat new to the FX40 (and JACE), could you give me a short tutorial? I have a line powered rs232 to rs485 converter. The N2 cable I'm confident I can figure out, the serial...
  12. Replies
    22
    Views
    2,596

    That's odd, the only thing mine brought to the...

    That's odd, the only thing mine brought to the yard was the neighbors St. Bernard... and he left something behind! :-)
  13. Replies
    22
    Views
    2,596

    Good luck with that! :-) The USB...

    Good luck with that! :-)




    The USB version works mint, I wish LonSpec would work with it, watch out for port conflicts between Rover and Lonspec if you have both installed.
  14. Thread: FX40 stuff

    by hvac_czar
    Replies
    12
    Views
    931

    Yeah, that's what I'm getting... RTU had LonMark...

    Yeah, that's what I'm getting... RTU had LonMark stickers all over it, opened it up and found BacNet card installed! :-(
  15. Thread: FX40 stuff

    by hvac_czar
    Replies
    12
    Views
    931

    Sorry, meant Workbench! Opened remote...

    Sorry, meant Workbench!

    Opened remote station... uploaded station... all controllers came online... opened controller and got "graphics file not found" error.
  16. Thread: FX40 stuff

    by hvac_czar
    Replies
    12
    Views
    931

    FX40 stuff

    Hey fellas,

    A question and an odd occurance while uploading an FX40... Is there any way to bring in a BacNet and an N2 bus into the same FX40? And, why do my graphics files not upload to the FX40...
  17. Replies
    28
    Views
    1,902

    How is the evaporator coil? Clean? Rated airflow?...

    How is the evaporator coil? Clean? Rated airflow? This is the first rule, before you even think about grabbing the refrigerant jug.

    Never lose the quest for knowlege, it is missing in most folks...
  18. Thread: FX Builder

    by hvac_czar
    Replies
    13
    Views
    2,343

    It is also worthwhile to note that you may be...

    It is also worthwhile to note that you may be able to write an app in FX Builder, specific to your job, using an FX07 that to use an FX Builder Express app would take an FX16 AND an FX15! This is JCs...
  19. Thread: FX Builder

    by hvac_czar
    Replies
    13
    Views
    2,343

    The Builder Express standard apps are as close to...

    The Builder Express standard apps are as close to HVAC Pro as you will get. For writing your own Builder apps you should really start off with the class offered by JC... Unless you are way above the...
  20. Replies
    14
    Views
    1,913

    How many would you like? I have 2 or 3 in fair...

    How many would you like?

    I have 2 or 3 in fair used condition.

    PM with reasonable offer.
  21. Replies
    4
    Views
    620

    OCC/UNOCC scheduler? I looked at the app and...

    OCC/UNOCC scheduler?

    I looked at the app and don't see anything other than that used to calculate common setpoint.
  22. Replies
    2
    Views
    473

    My understanding is that you would set up the...

    My understanding is that you would set up the interval between emails until the alarm is acknowleged, the directory sets the time between escalations of emails... ie, if you don't respond, how long...
  23. Replies
    10
    Views
    2,170

    Try registering it online using the exact same...

    Try registering it online using the exact same owner info you used to activate it the first time... I have successfully reinstalled Rover on the same machine it was originally installed on and...
  24. Replies
    5
    Views
    1,076

    http://www.emstec.com/class_description.php?id=113...

    http://www.emstec.com/class_description.php?id=113

    Google is your friend...
  25. Replies
    5
    Views
    1,041

    When I see a sequence like that it is generally...

    When I see a sequence like that it is generally for freeze protection... Before you modify anything, try to get inside the programmers head and don't eliminate a part of the sequence that in the end...
Results 1 to 25 of 500
Page 1 of 20 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event