  1. Replies
    2
    Views
    230

    Going there in the am to check it out,it sounds...

    Going there in the am to check it out,it sounds like its coming from the back of the heat exchanger but thats just me
  2. Replies
    15
    Views
    1,051

    Service is up a tad and thats it,had 2 customers...

    Service is up a tad and thats it,had 2 customers this week decide to buy there parts online not sure if they called back as there number is now blocked.The only furnace changeout i did was 3 weeks...
  3. Replies
    2
    Views
    230

    Lennox el195 clicking sound

    Lennox el195 installed 2 weeks ago and the customer can hear a clicking sound coming from the inducer and from the vent pipe outside.I have always heard a faint sound from all of these but run with...
  4. Replies
    20
    Views
    1,472

    it's vented with 2 inch 35 feet total with...

    it's vented with 2 inch 35 feet total with fittings I went there today made sure there was enough pitchback on the vent pipe also thinking if there was built up water when the inducer shut off any...
  5. Replies
    20
    Views
    1,472

    i am going there in the morning to see what i find

    i am going there in the morning to see what i find
  6. Replies
    20
    Views
    1,472

    No water in collector box.I pull inducer and...

    No water in collector box.I pull inducer and drain it it did this a week ago and I checked it 3 days ago and everything seemed to be draining fine I could not hear any water in inducer
  7. Replies
    20
    Views
    1,472

    Flu is pitched with no standing water in...

    Flu is pitched with no standing water in pipe,might locate trap at collector box it runs for a week that has me stumped
  8. Replies
    20
    Views
    1,472

    Lennox el296v drainage issue

    I have a el296070 furnace that runs fine for 2 weeks and then the inducer fills with water and shuts the unit down.The trap is not installed at the collector its at the rear of the furnace about 30"...
  9. Replies
    1
    Views
    193

    Coleman roof jack question

    I am changing a coleman model number 4084a656 to an updated model number dgaa075bdtb and need to know if the roof jack jacks are compatible?The one thats there is in great shape and changing it is...
  10. Replies
    2
    Views
    294

    Lennox vent termination kits

    Anyone using the diversitech hvent2 or hvent3 for vent terminations?There half the cost of the lennox ones.
  11. Replies
    5
    Views
    468

    ICP pressure switch issue

    Icp mod n8npm050b from 2006,the burner lights for 20 seconds and goes out.Flame sensor was good check pressure switch operation which closes at -.58 and goes to .-64 but when the burner lights it...
  12. Replies
    7
    Views
    471

    I will do that Jeep Sent from my Torque using...

    I will do that Jeep

    Sent from my Torque using Tapatalk
  13. Replies
    7
    Views
    471

    Thanks dawg i updated my profile and sent you a...

    Thanks dawg i updated my profile and sent you a message also
  14. Replies
    7
    Views
    471

    LG LS090CE MINI SPLIT

    Does anyone have a troubleshooting guide or parts manual for this mini-split,the comp starts but the condensing unit fan motor never starts and the system shuts down in a few min.
  15. Replies
    3
    Views
    363

    Subcool reading was taken at the condenser ...

    Subcool reading was taken at the condenser

    Sent from my Torque using Tapatalk
  16. Replies
    3
    Views
    363

    76 degrees Sent from my Torque using Tapatalk

    76 degrees

    Sent from my Torque using Tapatalk
  17. Replies
    3
    Views
    363

    H/V CHARGING ISSUE

    New system startup 2.5 ton r-410 h/v system readings are,s/h=12,s/c=3 12 deg d/t, low side 118psi,high side 195 psi.The first floor is a walkout basement temp was 70 deg second floor 75 deg both have...
  18. Baldies got it right there I've had four leakers...

    Baldies got it right there I've had four leakers all c6 miles to the three years old

    Sent from my Torque using Tapatalk
  19. Thread: run cap question

    by splus
    Replies
    51
    Views
    3,751

    I would change it to the right one for sure what...

    I would change it to the right one for sure what will it harm the motor having the bigger one on there

    Sent from my Torque using Tapatalk
  20. Thread: run cap question

    by splus
    Replies
    51
    Views
    3,751

    run cap question

    Was on a call where there was a 7.5 cap on a motor that called for a 5mfd cap,was installed 2 years ago and running fine.Will this be okay if left like this?
  21. My company WAS installing nordyne equipment for...

    My company WAS installing nordyne equipment for 15 yearswith no issues until the microchannel systems came out.Most leakers dont show up until the second year and trying to find them have been not...
  22. Replies
    2
    Views
    241

    Thanks dawg Sent from my Torque using Tapatalk

    Thanks dawg

    Sent from my Torque using Tapatalk
  23. Replies
    2
    Views
    241

    Lennox c33 liquid line stub

    Is the 3/8od liquid line stub available as a part if so i need a part number,also the one that comes with the coil has a teflon o-ring on it do i need to install the o-ring that comes inside the coil...
  24. Replies
    2
    Views
    295

    So a standard 2.5 ring will work if OEM is larger...

    So a standard 2.5 ring will work if OEM is larger

    Sent from my Torque using Tapatalk
  25. Replies
    2
    Views
    295

    Trane blower motor question

    Trane part number moto4717 3/4 hp motor,need to know if a standard motor with 2.5 inch resilient rings will work I seem to remember some of these have 2/5/8 rings
  26. Replies
    12
    Views
    743

    The chimney has a tile liner in it now its been...

    The chimney has a tile liner in it now its been running fine for 2 days now told the customer we need to evaluate the chimney and possibly put a alum liner in it

    Sent from my Torque using Tapatalk
  27. Replies
    12
    Views
    743

    The chimney is on the outside of the house and we...

    The chimney is on the outside of the house and we have had a week off record cold here below zero wind chill

    Sent from my Torque using Tapatalk
  28. Replies
    12
    Views
    743

    Yes it will vent fine no spillage at the water...

    Yes it will vent fine no spillage at the water heater I haven't taken any draft reading yet its been venting and the boiler and then cycling for 24 hours

    Sent from my Torque using Tapatalk
  29. Replies
    12
    Views
    743

    After pulling the vent pipe off of the vent...

    After pulling the vent pipe off of the vent damper of the boiler letting it bent into the basement for a minute putting the vent pipe back on the damper in its been venting fine

    Sent from my...
  30. Replies
    12
    Views
    743

    The boiler is 125000 BTU with a 40,000 BTU...

    The boiler is 125000 BTU with a 40,000 BTU standing pilot water heater jimmy is on the outside of the house 8 inch tile lined

    Sent from my Torque using Tapatalk
  31. Replies
    12
    Views
    743

    It extends one inch into the flu I checked it a...

    It extends one inch into the flu I checked it a fee hours later and it was venting fine

    Sent from my Torque using Tapatalk
  32. Replies
    6
    Views
    652

    Triangle tube boiler with the trimax control is a...

    Triangle tube boiler with the trimax control is a nice boiler.W/M makes a fire tube boiler also which is pretty much the same heat exchanger.
  33. Replies
    12
    Views
    743

    Boiler draft issue

    Get to a no heat call on a natural draft spark ignition boiler and find the roll out under the draft hood tripped.Boiler fires and I notice its not venting at all as in the vent pipe after the vent...
  34. Thread: Wet Switches

    by splus
    Replies
    9
    Views
    943

    I have used a hair dryer but have found to just...

    I have used a hair dryer but have found to just replace it as most will trip if there is high humidity in the attic area there very sensitive after you dry them
  35. Replies
    2
    Views
    572

    LINE SET SIZE QUESTION

    Got a trane 4ttb3018 with a 4txc18 coil i serviced it a few years back and it has a 5/8suction with a 1/4 liquid line.another company looked at it as i was 5 days out and said the liqiud line size...
  36. Replies
    2
    Views
    540

    ADP TXV PART NUMBER

    adp #te36430c245b 5-ton made in 2007 its a r-22 coil with txv i need a r-410 valve i did have one from a trane 4txc coil but the threads dont match up anyone know the adp or trane part number for the...
  37. Replies
    4
    Views
    913

    Are the condensing units microchannel?I am going...

    Are the condensing units microchannel?I am going to install a few furnaces and see i do like the condensate trap setup on them compared to the nordyne ones getting plugged all the time.
  38. Replies
    4
    Views
    913

    LENNOX MERIT SERIES

    Any feedback on the lennox merit series? i have been looking into a lower end line which still has a branded name on it i know its an air-flo unit,i really cant go with payne,goodman ect as most of...
  39. Thread: FIRST HEAT PUMP

    by splus
    Replies
    1
    Views
    579

    FIRST HEAT PUMP

    Go to help a good friend do a startup on a heatup system today and when i was configuring the stat there was no outdoor sensor which i know is an issue.There is a honeywell th8320u1008 there,after...
  40. Replies
    9
    Views
    1,593

    80% sidewall venting

    Was on a call yesterday for a water heater changeout and the homeowner asks me to change the filter a quick look in the attic and there is a 2 year old 80% forced air funace sidewall vented with...
  41. Replies
    6
    Views
    2,769

    I did take all the hoses off and made sure...

    I did take all the hoses off and made sure nothing was inside them,the furnace did cycle two times and then three days later i have the same pressure switch error.
  42. Replies
    6
    Views
    2,769

    Nordyne pressure switch ordeal

    I started a a/c install 3 days ago furnace is a nordyne kg7tc 2-stage that was installed 3 years ago with no issues.While do the low voltage wiring with new stat i deside to start furnace and check...
  43. Replies
    24
    Views
    2,797

    its a microchannel coil in the air handler?there...

    its a microchannel coil in the air handler?there is a charging chart on the cover of the outdoor unit use that.i have had some issues with charging these but when you get it right you will fine and...
  44. Replies
    3
    Views
    643

    i figured as much and its 7/8 after that to the...

    i figured as much and its 7/8 after that to the coil
  45. Replies
    3
    Views
    643

    Multiple size line set on unit

    Did a pm on a trane system older 4 ton txc coil no txv and a 3.5 ton r-410 4ttb outdoor.the line set was just under 50 feet at the coil its 7/8 suction but the last 8 feet to the condensing unit was...
  46. Replies
    14
    Views
    1,729

    Thanks for all the good info,i am running into...

    Thanks for all the good info,i am running into alot of systems that the airflow is either way to high or set on low speed and with days of 90 degrees an above a system not set up right on...
  47. Replies
    14
    Views
    1,729

    Airflow and system capacity

    So if i have a 2 ton split system r410 with 700 cfm across the coil system charged correct with a 18 degree temp drop across the coil and i adjust airflow to 900 cfm adjust charge and have a 16...
  48. Replies
    18
    Views
    2,100

    This is a straight cool system,the customer...

    This is a straight cool system,the customer called after having a few days to think about it and said they understand this is a roll of the dice.another point i need to bring up is the outdoor unit...
  49. Replies
    18
    Views
    2,100

    according to the paperwork that came with the...

    according to the paperwork that came with the coil it uses the same txv for 2 thru 3 ton coils,its a aspen slab coil and the customer called and is willing to try and i mean try what ever i think i...
  50. Replies
    31
    Views
    3,722

    Is the coil a new c7 microchannel cased coil and...

    Is the coil a new c7 microchannel cased coil and if so did you add a txv or use the piston that came with the coil?if its a piston is it the correct size as i have a few of these out there and in the...
Results 1 to 50 of 496