    it is a dx coil and single stage.the compressor...

    it is a dx coil and single stage.the compressor does shutb off at the end for cooling
  2. Replies
    3
    Views
    1,091

    has anyone delt with magic aire fan coil ahu with...

    has anyone delt with magic aire fan coil ahu with hot water coil,my problem is that when the a/c is running condesate drips off of the evap. coil and in some cases it is so bad that it almost looks...
  3. Thread: Mcquay screw

    by reggio
    Replies
    66
    Views
    7,252

    i have heard of this problem and from my...

    i have heard of this problem and from my undrstanding from mquay that they do have retrofit recieaver kit with some basic repiping iguess the problem they found was poor oil return, and even with...
  4. Replies
    7
    Views
    974

    according to magic aire splash gauges are not...

    according to magic aire splash gauges are not required,this is not a chilled water system it is a bqsic r22 refrig system. i have checked cfm and it is close to design of 1100 cfm and but i did...
  5. Replies
    7
    Views
    974

    thanks for the reply ,i was thinking the same...

    thanks for the reply ,i was thinking the same thing , but these units are direct drve and it is a open return with no duct work just the opening in the unit and a filter. i can not think of a good...
  6. Replies
    7
    Views
    974

    i nhave several magic aire fan coil units modle...

    i nhave several magic aire fan coil units modle #o24-kvx--b-3-3 units, my problem is the evaporators are dripping several drops of water off of the coil while the unit is running and when the unit...
  7. Thread: piping question

    by reggio
    Replies
    11
    Views
    1,747

    not paying attention to my spelling ,kids wont...

    not paying attention to my spelling ,kids wont leave me alone
  8. Thread: piping question

    by reggio
    Replies
    11
    Views
    1,747

    thx for the reply, im not sure the m# my...

    thx for the reply, im not sure the m# my clipboard is on the job, but is a trane climatemaster hot and cold deck. the ahu has a 100 ton evap that is split up with 2circuits at 50 tons. iam relacing...
  9. Thread: piping question

    by reggio
    Replies
    11
    Views
    1,747

    help, I have a trane 50 ton condencer (rauc-c50)...

    help, I have a trane 50 ton condencer (rauc-c50) with a 1 evaporator and 1 txv, the condencer came out with 2 circuits a first and second stage. my ? is can i pipe the second stage into the first...
  10. Replies
    89
    Views
    15,500

    you are right trane is a closed loop, ideal with...

    you are right trane is a closed loop, ideal with trane tracer alot, we also istall abunch of these systems. when it comes to getting software you either have to go threw the owner of the...