  1. Replies
    9
    Views
    1,137

    Vertical, Horizontal its all the same in space....

    Vertical, Horizontal its all the same in space. Old copper drain was higher up at some time and they either missed it or were ignorant when connecting to most recent unit. Looks to low to turn 90 deg...
  2. Replies
    13
    Views
    1,034

    Looks like the condenser fan took off! Unit is...

    Looks like the condenser fan took off! Unit is much newer than others, they usually give a new condenser when comps go out on mini's. Definitely a over charge of something, maybe between high...
  3. Replies
    3
    Views
    740

    Is it one central filter at unit or is filter in...

    Is it one central filter at unit or is filter in return grille(s)? Had a similar situation while back, except a house/business for a hair stylist not cooling . I looked at filters first, used but...
  4. Replies
    13
    Views
    1,496

    State Inspector? or a city/county inspector in...

    State Inspector? or a city/county inspector in state of MN? Neatness is for paying jobs... I hope all the labels are correct. Colored tape is for guys with a bad memory.
  5. Replies
    32
    Views
    4,102

    Some field work required, wouldnt mind running...

    Some field work required, wouldnt mind running the line set on that split system. Would not want anything to do with the minis though, would quote to correct, and make it worth the hassle, but when...
  6. Replies
    2
    Views
    1,454

    All the work they put into that and still failed....

    All the work they put into that and still failed. Regardless, the roof still has a leak.
  7. With that gap around that termination, it should...

    With that gap around that termination, it should be fine.... :rolleyes:
  8. By the way, is that a ARUF A/H or, I'm assuming,...

    By the way, is that a ARUF A/H or, I'm assuming, a ASUF or other with ECM Blower?
  9. Good job catching and taking care of it. To many...

    Good job catching and taking care of it. To many would have changed the bad cap and hit the road even if they did notice the undersized duct and the obvious solution.
  10. Replies
    8
    Views
    2,967

    Had a similar situation. New construction house...

    Had a similar situation. New construction house (air handlers in attic) where the buyers added/extended a concrete slab patio at back of house where the condensate drains terminated. They had...
  11. Thread: The irony

    by Rodney28334
    Replies
    14
    Views
    2,455

    I get a kick out of the minisplit controls' Asian...

    I get a kick out of the minisplit controls' Asian translations and icons. love the "Powerful" and "Mustache" buttons
  12. Very neat and clean install, I hate having to...

    Very neat and clean install, I hate having to splice different color wire but he kept it visible. That humidifier trap is unique to say the least but functional. Yea, I don't like taking short cuts...
  13. I hope he means a heat pump, they make mobile...

    I hope he means a heat pump, they make mobile home electric furnaces with heatpump coils and condensers, and it wouldn't cost much more than a electric heat only and AC system, and a conventional...
  14. Replies
    11
    Views
    638

    "Air flow gumming up deep interior."? As in the...

    "Air flow gumming up deep interior."? As in the blower airflow or the vent flue "air" flow? If the vent is run incorrectly it can cause soot to build up in venting, and venting restriction could...
  15. Replies
    18
    Views
    1,141

    Missed the last few posts. How bad are the...

    Missed the last few posts. How bad are the scratches, Pics? If the scratches are very deep or the powder coating is rubbed off it can cause premature oxidation, but as long as it isn't dented I...
  16. Replies
    18
    Views
    1,141

    What is the model number of your furnace? It...

    What is the model number of your furnace? It also plays a roll in the ratings, if it has a ECM blower it will get a better rating than a psc blower, ect.. I wouldn't worry about the coil to much,...
  17. A load calc is key, but I can comfortably say...

    A load calc is key, but I can comfortably say that your existing unit is oversized. Your thinking is correct, higher upfront cost but make sure that the equipment is sized correctly, as a over sized...
  18. Replies
    19
    Views
    4,802

    Engineering is basically observed failure so he...

    Engineering is basically observed failure so he will learn his lesson when he impales something, and hopefully not some one.
  19. Looks good, as said I wouldn't have hung it but...

    Looks good, as said I wouldn't have hung it but the goliath pans are great no blocks or risers needed, built in float switch, rubber "isolators" but pricy and you have to lay it in right or a panel...
  20. Replies
    34
    Views
    5,465

    Owns a indoor conditioned swimming pool and cant...

    Owns a indoor conditioned swimming pool and cant pay for service. I hope they removed the horizontal pan if they rigged the right side to pull air through coil. They might as well plan on changing...
  21. Replies
    7
    Views
    1,556

    Thanks, will be leaving the shop today with an...

    Thanks, will be leaving the shop today with an extra ceiling register, drywall saw and a few materials.
  22. Replies
    17
    Views
    2,915

    All it needs is a few more coats of mastic. The...

    All it needs is a few more coats of mastic. The key is to let it dry between coats :eek2:
  23. Replies
    7
    Views
    2,963

    Understood, sarcasm has a habit of going over my...

    Understood, sarcasm has a habit of going over my head :det: The 90's are plenty but neat.
  24. Replies
    7
    Views
    2,963

    Condenser unit "4" with zig-zag suction line?

    Condenser unit "4" with zig-zag suction line?
  25. Replies
    4
    Views
    2,497

    Very cool, had a cat take a swing at me for...

    Very cool, had a cat take a swing at me for trying to get a temp D from a vent he was "using". I checked from a different register.
  26. Replies
    22
    Views
    4,078

    We used to do all the HVAC work for some local...

    We used to do all the HVAC work for some local housing authorities, not maintenance. Each one has 2 maintenance men who are supposed to replace filters and clean coils ect.. along with their other...
  27. Replies
    40
    Views
    3,208

    If its 101 outside and the unit cycles twice an...

    If its 101 outside and the unit cycles twice an hour to keep it at 72, I would say its oversized technically. It could be correctly sized to a custom outdoor and indoor design temp, IE.. 107 ODT w/...
  28. Replies
    3
    Views
    875

    Look more into who is installing it rather than...

    Look more into who is installing it rather than what it is. You can have the nicest newest system, and if its installed incorrectly you have a expensive mess. To the Goodman-Amana issues.. They push...
  29. Replies
    4
    Views
    526

    Also, blowers run longer to get the last bit of...

    Also, blowers run longer to get the last bit of heat or cooling out of the coil, when the system stops, usually 45 secs but depending on the system could be much longer. Most likely just the fan is...
  30. Replies
    11
    Views
    975

    I would go with one of the contractors that did...

    I would go with one of the contractors that did the calc, and would suggest putting in a second return with a 4 Ton. The size of the return duct behind the 24x24 grille is just as important as the...
  31. Replies
    6
    Views
    565

    Have contractor come back out and look at the...

    Have contractor come back out and look at the system, specifically the control wires. If ductwork is undersized on a zone system, especially single stage compressors with psc or X13 blower motors...
  32. Replies
    16
    Views
    1,311

    Have a combustion test done on all the gas...

    Have a combustion test done on all the gas appliances and see how it looks. The tester should know this but make sure they do one with all the equipment running at same time. It could be fine the way...
  33. It seems like the blanked coil is the issue....

    It seems like the blanked coil is the issue. Being in CO you need more heat than air conditioning. Sounds like they just put a small 3 ton coil on the big 90k furnace, which is most likely also...
  34. X2 Variable speed compressors need to be...

    X2 Variable speed compressors need to be "communicating" systems and every brand has their own proprietary system. If you mean variable speed blower (way more common) then you can use any...
  35. Replies
    7
    Views
    684

    10kw, preferably 2 staged is best bet. It isn't...

    10kw, preferably 2 staged is best bet. It isn't to big, but will give you enough emergency heat to stop it from getting to cold if Heat pump goes out at bad time. A calc needs to be done, but being...
  36. Is the duct sized for the coil? Or does it have a...

    Is the duct sized for the coil? Or does it have a transition going to bigger duct after the coil? to get the "resistance" of coil a reading must be taken before and after the coil. .4 WC is way...
  37. Replies
    12
    Views
    821

    X2 on a no for Nutone/Nordyne and Goodman gas...

    X2 on a no for Nutone/Nordyne and Goodman gas packs are a pain to work on. Not much lennox or York experience. If you go with Trane make sure to get at least a XL13, as it has a 20yr Heat exchanger...
  38. Replies
    16
    Views
    1,155

    I assume he used Wrightsoft, which is a good...

    I assume he used Wrightsoft, which is a good program but there are so many variables it is easy for contractors to make it look like it needs more capacity than it really does. Like infiltration...
  39. 300psig head pressure is pretty high for a r22...

    300psig head pressure is pretty high for a r22 system. I understand its vegas and a rooftop unit but it could be working its way higher throughout the day which can cause the unit to shutdown and...
  40. They don't make them like they used to! I have...

    They don't make them like they used to! I have an aunt who lives alone and uses 2 110v window units in her small old singlewide and the ducts are a mess and existing original coleman electric...
  41. Home many zones do you have? If you have a 2...

    Home many zones do you have? If you have a 2 story house with 2 zones one for each floor, and a centrally located thermostat on each floor, a remote sensor will not help. The thermostat should be...
  42. Replies
    12
    Views
    632

    I think you meant PG92s and I don't am not...

    I think you meant PG92s and I don't am not familiar with the GMMV model#, but assume its a Variable speed blower version of G9MXE. Payne and Day and Night are the same, and I would suggest the Day...
  43. Replies
    18
    Views
    1,216

    If mechanical room is on same level as the bonus...

    If mechanical room is on same level as the bonus room, why not just put a extra return and a extra supply register or 2 in shared wall btw bonus and Mech room? I am assuming that the ceiling is roof...
  44. Replies
    18
    Views
    1,216

    You are lucky that the mechanical room is on the...

    You are lucky that the mechanical room is on the 3rd/ Bonus Room Floor. As has been said the only way to correctly solve this is zoning by modifying your existing system or adding a separate system...
  45. Replies
    7
    Views
    552

    a 4 degree temp swing is pretty noticeable, and...

    a 4 degree temp swing is pretty noticeable, and would be uncomfortable to most people.
  46. Replies
    7
    Views
    647

    Seems like they accidently crossed high voltage...

    Seems like they accidently crossed high voltage into the 24v controls. I don't see how this could have directly damaged the compressor or any other 240 volt motor. If they were checking the...
  47. I have not installed a Lennox, but am a HEIL...

    I have not installed a Lennox, but am a HEIL (Comfortmaker), Trane (American Standard) and Goodman (previously) dealer. As you have heard installation is more important than the brand of equipment. ...
  48. Replies
    33
    Views
    6,495

    Reminds me of a while back when the Hyperion...

    Reminds me of a while back when the Hyperion first came out. I pulled up on a job site and one of the installers had the coil out trying to flip it! He was happy to learn that it was multi position...
  49. Replies
    6
    Views
    2,821

    Better to pull controls out than go to the coil...

    Better to pull controls out than go to the coil with a ice pick or screwdriver.
  50. plastic tie bands/straps FTW.

    plastic tie bands/straps FTW.
Results 1 to 50 of 432