Search:

Type: Posts; User: second opinion

Page 1 of 20 1 2 3 4

Search: Search took 0.06 seconds.

  1. I bet he picks Arzel as I would

    I bet he picks Arzel as I would
  2. Can you post pictures of leak location?

    Can you post pictures of leak location?
  3. Replies
    13
    Views
    595

    No need to change with that diagnosis

    No need to change with that diagnosis
  4. The fan housing will block the majority of the...

    The fan housing will block the majority of the opening
  5. 100% outside air for return

    100% outside air for return
  6. Replies
    13
    Views
    441

    Make up air required to be tempered within 10...

    Make up air required to be tempered within 10 degrees of indoor air. IMC 508.1.1
  7. Replies
    13
    Views
    441

    I agree shophound, isn't it amassing the lack of...

    I agree shophound, isn't it amassing the lack of knowledge base that is not required to be a contractor. This is an overkill for most residential applications, but some individuals have more money...
  8. Replies
    8
    Views
    408

    The caps are no big deal and IMHO are a waste of...

    The caps are no big deal and IMHO are a waste of time and money for the consumer and proposals are made to rescend the requirement.

    The drains being tied together is clearly a FUBAR. The purpose...
  9. Let the charge loose, your readings exceed...

    Let the charge loose, your readings exceed industry standards and with non-vacuum rated equipment the slight increase is to be expected.
  10. Even better, they should be required to measure...

    Even better, they should be required to measure static pressure, show the refrigerant data (temps & pressures) and certify the unit after installation. If static pressure is high, you can recalculate...
  11. With all mfg. only one combination in the series...

    With all mfg. only one combination in the series has to meet the rating and all others will qualify.
  12. I agree wayyyyyyy over sized = short cycles, high...

    I agree wayyyyyyy over sized = short cycles, high humidity, extra cost etc.

    A proper design with manual D,J,and S is needed
  13. Replies
    8
    Views
    408

    Primary and secondary can not be tied together....

    Primary and secondary can not be tied together. There are four options for auxiliary drain pan. IRC 1411.3.1
  14. Replies
    21
    Views
    772

    Sling also designed to use with distilled water

    Sling also designed to use with distilled water
  15. Replies
    12
    Views
    430

    Tell your dealer you want the XL15I and forget...

    Tell your dealer you want the XL15I and forget the other choices. Invest in lowering the heat load of the structure, and most important is the proper air flow
  16. Replies
    4
    Views
    194

    Can you post a picture? It may be as simple as...

    Can you post a picture? It may be as simple as the float hanging on a Clear View trap
  17. Replies
    6
    Views
    252

    [QUOTE=marylandtech;15674881]Thanks for the info!...

    [QUOTE=marylandtech;15674881]Thanks for the info! What type of complications could I have??. I was going to seal the pipe to keep water out and oversize the conduit to have additional free space...
  18. Replies
    6
    Views
    252

    Be quite cautious, you will be not only at the...

    Be quite cautious, you will be not only at the piping limits but adding the underground leads to complications.
  19. Replies
    9
    Views
    293

    He would be correct, what ever insulation that is...

    He would be correct, what ever insulation that is covering the duct would need to have a vapor barrier over it to prevent condensation from being formed in the insulation.
  20. IRC 303.3 mechanical ventilation not required,...

    IRC 303.3 mechanical ventilation not required, but is an option to the ventilation requirements for bathrooms
  21. Replies
    18
    Views
    543

    You have a FUBAR and the system will not work.

    You have a FUBAR and the system will not work.
  22. A wet and dry vac will work better and will not...

    A wet and dry vac will work better and will not cause damage from pipe separation if not glued
  23. Looking at your second picture, the pipe exiting...

    Looking at your second picture, the pipe exiting on the left and turning right with the trap and vent is the primary
  24. When water freezes it will exert a pressure of...

    When water freezes it will exert a pressure of 2000 lbs.psi
  25. It would appear that your insulating company is...

    It would appear that your insulating company is fare more competent than your
    (very reputable, highly recommended,never heard any complaints, excellent service company, does many foam houses) is.
Results 1 to 25 of 500
Page 1 of 20 1 2 3 4