05-08-2013, 07:33 PM
- Replies
- 35
- Views
- 661
I bet he picks Arzel as I would
I bet he picks Arzel as I would
-
05-08-2013, 01:26 PM
- Replies
- 17
- Views
- 622
Can you post pictures of leak location?
Can you post pictures of leak location?
-
05-03-2013, 10:21 PM
Thread: Is this Condensor Fan Motor bad?
by second opinion- Replies
- 13
- Views
- 595
No need to change with that diagnosis
No need to change with that diagnosis
-
05-03-2013, 05:52 PM
- Replies
- 8
- Views
- 433
The fan housing will block the majority of the...
The fan housing will block the majority of the opening
-
05-03-2013, 04:26 PM
- Replies
- 4
- Views
- 343
100% outside air for return
100% outside air for return
-
05-03-2013, 04:22 PM
Thread: Kitchen exhaust hood make up air
by second opinion- Replies
- 13
- Views
- 441
Make up air required to be tempered within 10...
Make up air required to be tempered within 10 degrees of indoor air. IMC 508.1.1
-
05-03-2013, 01:49 PM
Thread: Kitchen exhaust hood make up air
by second opinion- Replies
- 13
- Views
- 441
I agree shophound, isn't it amassing the lack of...
I agree shophound, isn't it amassing the lack of knowledge base that is not required to be a contractor. This is an overkill for most residential applications, but some individuals have more money...
-
05-03-2013, 12:02 PM
Thread: failed inspection: drain pan
by second opinion- Replies
- 8
- Views
- 408
The caps are no big deal and IMHO are a waste of...
The caps are no big deal and IMHO are a waste of time and money for the consumer and proposals are made to rescend the requirement.
The drains being tied together is clearly a FUBAR. The purpose... -
05-03-2013, 10:19 AM
- Replies
- 17
- Views
- 746
Let the charge loose, your readings exceed...
Let the charge loose, your readings exceed industry standards and with non-vacuum rated equipment the slight increase is to be expected.
-
05-03-2013, 08:16 AM
- Replies
- 15
- Views
- 643
Even better, they should be required to measure...
Even better, they should be required to measure static pressure, show the refrigerant data (temps & pressures) and certify the unit after installation. If static pressure is high, you can recalculate...
-
05-03-2013, 08:03 AM
- Replies
- 15
- Views
- 643
With all mfg. only one combination in the series...
With all mfg. only one combination in the series has to meet the rating and all others will qualify.
-
05-03-2013, 07:54 AM
- Replies
- 27
- Views
- 717
I agree wayyyyyyy over sized = short cycles, high...
I agree wayyyyyyy over sized = short cycles, high humidity, extra cost etc.
A proper design with manual D,J,and S is needed -
05-03-2013, 07:49 AM
Thread: failed inspection: drain pan
by second opinion- Replies
- 8
- Views
- 408
Primary and secondary can not be tied together....
Primary and secondary can not be tied together. There are four options for auxiliary drain pan. IRC 1411.3.1
-
05-01-2013, 10:44 AM
Thread: digital psychrometer
by second opinion- Replies
- 21
- Views
- 772
Sling also designed to use with distilled water
Sling also designed to use with distilled water
-
05-01-2013, 10:39 AM
Thread: New AC 2-stage confusion HELP!
by second opinion- Replies
- 12
- Views
- 430
Tell your dealer you want the XL15I and forget...
Tell your dealer you want the XL15I and forget the other choices. Invest in lowering the heat load of the structure, and most important is the proper air flow
-
04-30-2013, 11:00 PM
Thread: Safety Float switch issues
by second opinion- Replies
- 4
- Views
- 194
Can you post a picture? It may be as simple as...
Can you post a picture? It may be as simple as the float hanging on a Clear View trap
-
04-30-2013, 10:08 PM
Thread: Trane refrigerant piping length
by second opinion- Replies
- 6
- Views
- 252
[QUOTE=marylandtech;15674881]Thanks for the info!...
[QUOTE=marylandtech;15674881]Thanks for the info! What type of complications could I have??. I was going to seal the pipe to keep water out and oversize the conduit to have additional free space...
-
04-30-2013, 06:35 PM
Thread: Trane refrigerant piping length
by second opinion- Replies
- 6
- Views
- 252
Be quite cautious, you will be not only at the...
Be quite cautious, you will be not only at the piping limits but adding the underground leads to complications.
-
04-30-2013, 04:58 PM
Thread: Buried or above the insulation
by second opinion- Replies
- 9
- Views
- 293
He would be correct, what ever insulation that is...
He would be correct, what ever insulation that is covering the duct would need to have a vapor barrier over it to prevent condensation from being formed in the insulation.
-
04-30-2013, 10:46 AM
- Replies
- 8
- Views
- 308
IRC 303.3 mechanical ventilation not required,...
IRC 303.3 mechanical ventilation not required, but is an option to the ventilation requirements for bathrooms
-
04-29-2013, 11:32 PM
Thread: Line Set vs Charge Assist Help
by second opinion- Replies
- 18
- Views
- 543
You have a FUBAR and the system will not work.
You have a FUBAR and the system will not work.
-
04-29-2013, 09:13 PM
- Replies
- 11
- Views
- 405
A wet and dry vac will work better and will not...
A wet and dry vac will work better and will not cause damage from pipe separation if not glued
-
04-29-2013, 08:07 PM
- Replies
- 11
- Views
- 405
Looking at your second picture, the pipe exiting...
Looking at your second picture, the pipe exiting on the left and turning right with the trap and vent is the primary
-
04-26-2013, 10:59 AM
- Replies
- 14
- Views
- 481
When water freezes it will exert a pressure of...
When water freezes it will exert a pressure of 2000 lbs.psi
-
04-26-2013, 10:55 AM
- Replies
- 28
- Views
- 773
It would appear that your insulating company is...
It would appear that your insulating company is fare more competent than your
(very reputable, highly recommended,never heard any complaints, excellent service company, does many foam houses) is.