  1. pull the burner and check for a burned out blast...

    pull the burner and check for a burned out blast tube,,you may be able to check this if you use a flame mirror with the gun (nozzle assembly) removed,Should be zero even with the blower moter on...
  2. Replies
    6
    Views
    569

    direct 1sq inch per 2000 btus

    direct 1sq inch per 2000 btus
  3. Replies
    7
    Views
    2,438

    we had to drain two 250hp boilers @north...

    we had to drain two 250hp boilers @north Attleboro,state of mass considers straight boiler water as a pollutant thanks to barney frank,so glycol is also considered toxic and must be...
  4. Replies
    4
    Views
    1,908

    thank you for your reply,,ive purchased the...

    thank you for your reply,,ive purchased the configuration tool (which is used in place of a laptop setup).My problem lies with watching the curser as it travels along the curve,from a red box...
  5. Replies
    7
    Views
    2,878

    ill bet you ,,yes use a 12,000 volt standard...

    ill bet you ,,yes use a 12,000 volt standard carlin transformer,you know the big heavy black kind,and ground it ,youll be fine
  6. hope this works ,i lost first reply,put in new...

    hope this works ,i lost first reply,put in new style keypad go to valve proving, key in NEVER,ONLY IF CONTROL HAS LESS THAN 200 HRS,THErepower pull out purge card fault will show code one ,kill power...
  7. Replies
    4
    Views
    1,908

    honeywell control links,,problem

    heres a tough one ,i got a problem with honeywell control links,im hoping im not the only person in america that is facing this,i own a mechinical contracting business ,big deal,been in this business...
  8. back pressure at the burner head could be the...

    back pressure at the burner head could be the problem,i have in the past had to remove the cast iron baffles out of some buderis boilers,i suggest you hook up a manometer to the pilot tee and measure...
  9. Replies
    8
    Views
    2,633

    convert it to uv

    convert it to uv
  10. Replies
    4
    Views
    716

    nazi boilers

    buy american the job you save could be your own!!!!!!!!!!!!!!!!!!
  11. gauge glass

    first off what pressure are you running? we only red line 5/8 dia. gauge glass ,if over 15 psi use high pressure washers (red),cut the glass with a chain cutter ,place it into the cocks so it does...
  12. Replies
    18
    Views
    7,005

    pilot problem

    first off i would recomend a flooded pilot test,described in the owners manual ,next i would upgrade the pilot assembly to a uv style,i suspect the burner has a 7895a honeywell control you will need...
  13. Thread: boiler room

    by boilernazi
    Replies
    8
    Views
    856

    looks like an old generator,was this boiler room...

    looks like an old generator,was this boiler room steam operated?
  14. Replies
    18
    Views
    4,083

    weil mclain boilers require the breeching damper...

    weil mclain boilers require the breeching damper to be set to a positive pressure of.01,,check overfire pressure to see if it matches what the boiler was designed for ,,this will find section...
  15. Replies
    7
    Views
    883

    we use this trick to prevent tampering also,to...

    we use this trick to prevent tampering also,to keep a dated record on who was there last ,some use nickles.another trick in use is to pull out the perge time card on 7800 controls to leave the last...
  16. Replies
    4
    Views
    707

    YES,,,it is way outside the code!!!!!!!!!!!you...

    YES,,,it is way outside the code!!!!!!!!!!!you cant even use plastic for a vent!!!!!!!
  17. Replies
    13
    Views
    1,460

    pull the burners out,sounds like they are burned...

    pull the burners out,sounds like they are burned up,NFPA,,,co level must not exceed 300 ppm.
  18. Replies
    17
    Views
    1,888

    impingment on back wall?,three section is quite...

    impingment on back wall?,three section is quite short id use a monarch 70 degree hollow,nozzle@105psi,,inpingment is the fire comming in contact with the boiler surface or oil spray hitting the end...
  19. Replies
    7
    Views
    1,297

    ever see a 30 year old copper boiler?not...

    ever see a 30 year old copper boiler?not likely,,,,,cast iron is best