Search:

Type: Posts; User: kbwk2mch

Page 1 of 3 1 2 3

Search: Search took 0.01 seconds.

  1. hope this helps speed things up with a JADE upgrade -- economizer

    http://www.tecmungo.com/wordpress/?p=399
  2. BRAZE torch is out .. do it right

    BRAZE torch is out .. do it right
  3. Replies
    42
    Views
    17,344

    I had something similar. supplier counter guy,...

    I had something similar. supplier counter guy, dad refrigeration guru. said... if com[ressor hot, condensor cold it's a plugged cap tube. I reclaimed, blew nitrogen both ways. installes a real...
  4. Thread: Allowable CO

    by kbwk2mch
    Replies
    20
    Views
    1,488

    I read post better ... If you inquired and he...

    I read post better ... If you inquired and he tested with a co only meter . I stand by my post. If he stuck a combustion analyzer in ..... I agree ... he doesn't know what he is doing or it's a...
  5. Thread: Allowable CO

    by kbwk2mch
    Replies
    20
    Views
    1,488

    Get an alarm as stated b4. u have heat :) start...

    Get an alarm as stated b4. u have heat :) start pricing a new furnace asap
  6. Replies
    16
    Views
    1,209

    I agree with U !! except for the losing ground...

    I agree with U !!
    except for the losing ground part ?
  7. Trane CGWD process chiller new to me how do I clean condensor barrell??

    I have this unit at a chemical plant. Limited shut-down time. I need to clean the condenser barrel on next shut down. Hard piped on inlet and outlet. Looks like 2 barrells in series. bottom has a U...
  8. Replies
    52
    Views
    8,351

    NU 22 is a " drop in" it's 40....something. mfg....

    NU 22 is a " drop in" it's 40....something. mfg. is helpful. They have lots of "cool" stuff. It is a blend. someone earlier said small amounts may work if p/t close... I sorta agree. I would pull...
  9. Thread: Trane RTU

    by kbwk2mch
    Replies
    15
    Views
    1,186

    Like I read above at that age Lord knows who...

    Like I read above at that age Lord knows who touched it. No IAQ controls??? Maybe linkage wrong or wrong motor ??Both dampers move together correct ??
  10. Replies
    5
    Views
    785

    Don't know why albany?? probbably lots of...

    Don't know why albany?? probbably lots of residential work. commercial is slow except for a few companies doing Construction. Ualocal7.org or com not sure for commercial/ indudtrial service and...
  11. Thread: Ice forming

    by kbwk2mch
    Replies
    5
    Views
    782

    I agree with beenthere. It might be 1 million...

    I agree with beenthere. It might be 1 million things....or nothing at all??
  12. Replies
    1
    Views
    679

    Not that I am aware. We try to run a main trunk...

    Not that I am aware. We try to run a main trunk and run flex off it. I have seen some hacks install a plenum on airhandler and hook flex everywhere. This somehow works. We have a short a/c season.
    ...
  13. Replies
    15
    Views
    1,657

    I'm not sure where you live but .....if it is...

    I'm not sure where you live but .....if it is less than freezing for a good part of winter I would go with a fossil fuel aux. heat.....make it primary in real cold weather. Any temp above 40 deg. a...
  14. Thread: limit switch

    by kbwk2mch
    Replies
    8
    Views
    946

    Your local carrier dealer will have it. I thought...

    Your local carrier dealer will have it. I thought thr one with the yellow stripe was the roll-out switch up over the inducer motor?? Tell carrier where it goes in case someone B4 U installed...
  15. Replies
    13
    Views
    2,448

    OOOOPPPPS, you are going to natural gas sorry. If...

    OOOOPPPPS, you are going to natural gas sorry. If your selling the home and oil tank is in good shape you could just replace oil boiler.
    As far as your question. I like theon demand direct vent...
  16. Replies
    13
    Views
    2,448

    Is it cheaper to switch fuels? Just because your...

    Is it cheaper to switch fuels? Just because your old boiler was not running properly or repaired correctly your changing fuels? Unless Natural gas is available I would stick with oil. Buderus with...
  17. Replies
    60
    Views
    5,681

    The shinny SIN WRAP helps........That releif...

    The shinny SIN WRAP helps........That releif valve isn't fixed yet!
  18. Replies
    11
    Views
    907

    Is this position filled yet ???? Are you...

    Is this position filled yet ????
    Are you residential or commercial????
  19. Replies
    18
    Views
    2,282

    What about the cost of oil maintainance vs....

    What about the cost of oil maintainance vs. oil??? I had 8 yrs of oil co. exp. brainwashing me how much oil is better,cheaper etc etc. I now feel it is dirtier...even with new equiptment, noisier,...
  20. Replies
    18
    Views
    2,282

    Buderus witha riello burner can be up to 86%...

    Buderus witha riello burner can be up to 86% effiecient. You should get direct vent or linr your chimney to prevent flue gas condensation. Buderus also makes a wall hung gas boiler like a tankless...
  21. Replies
    11
    Views
    912

    Another question. was G actually green R red, y...

    Another question. was G actually green R red, y yellow etc. If not you crossed something. Sometimes r is green y is red and b is green??
  22. Replies
    5
    Views
    1,003

    A dirty evaporator can also allow the...

    A dirty evaporator can also allow the water(condensate) droplets to run off before the bottom and into the pan.
  23. Replies
    10
    Views
    1,734

    I think Rhhem and Rhuud are pretty much the same....

    I think Rhhem and Rhuud are pretty much the same. You are probbably refering to supply air temp and humidity sensors?
    I don't know much about Rheem/Rhuud but most every brand has touch screen stats....
  24. Thread: Lawn Tractors

    by kbwk2mch
    Replies
    23
    Views
    1,840

    An old Cub cadet or John Deere from the 70's is...

    An old Cub cadet or John Deere from the 70's is one tough multi purpose tractor.
  25. Thread: Thermostat

    by kbwk2mch
    Replies
    1
    Views
    580

    I don't see a difference with new electronic...

    I don't see a difference with new electronic digital ones.. With mercury bulb if no time delays on unit you can lower if unit is running or if not. just dont go up and down over and over......why...
  26. Replies
    339
    Views
    45,892

    Karl Albany N.Y. area. started in residential...

    Karl Albany N.Y. area. started in residential knew nothing. 8 years later with lots of good training was required to be "the man" with no more pay or beni's then guys that did half as much. Went into...
  27. Thread: New Guy

    by kbwk2mch
    Replies
    9
    Views
    1,082

    If you came from residential did you ever work on...

    If you came from residential did you ever work on a mobile home pakage air conditioner? A rtu is the same. differences are a heating pakage...also similar to residential. most rtu's have first and...
  28. Replies
    21
    Views
    3,854

    yeah even a/c pumps heat.

    yeah even a/c pumps heat.
  29. Replies
    10
    Views
    1,734

    thermocouple in the return duct ??? I would get...

    thermocouple in the return duct ???
    I would get a brand name well warranteed system from a reputable contractor. Ask them what the pay back is. You may be suprised....You get what you pay for.
  30. Replies
    19
    Views
    1,381

    It's hard to find guys that can't put 5 different...

    It's hard to find guys that can't put 5 different colored wires on labeled connections???? or do you guys run 3 2 conductor wires just to keep it interesting.

    In residential it's always fun to...
  31. Replies
    7
    Views
    812

    I agree close them off. Also vent the attic area...

    I agree close them off. Also vent the attic area well. It will prolong roof life and lower heating and cooling costs.
  32. Replies
    15
    Views
    5,854

    I like it when they smell something coming from...

    I like it when they smell something coming from the test holes when you don't cover them. If odors are coming outta ther lady you got big problems!
  33. Thread: QUAD??

    by kbwk2mch
    Replies
    54
    Views
    12,385

    The relays are not solid state. I agree with most...

    The relays are not solid state. I agree with most other postings. Hey if it works it works. You have to do the best you can with eveyones budget in mind.
  34. Replies
    7
    Views
    812

    If theytruly just go to the attic they must be...

    If theytruly just go to the attic they must be for depressurisation. Is this like a GE modular ?? I've never seen what you are describing.
  35. Replies
    11
    Views
    2,142

    sounds like loops to warm. Is this the only unit...

    sounds like loops to warm. Is this the only unit havung trouble? many of the ones I work on have backflush kits on them you basically flush from the outlet of the water coil tothe closed off inlet...
  36. Thread: credentials

    by kbwk2mch
    Replies
    10
    Views
    793

    I changed careers and now do HVAC work.....Can I...

    I changed careers and now do HVAC work.....Can I play now?LOL
    I'm going to bed will check this out more tommorrow.
    Thanks guys!
  37. Thread: credentials

    by kbwk2mch
    Replies
    10
    Views
    793

    Mr. Associate. can you answer my question? I...

    Mr. Associate. can you answer my question? I tried to e-mail question at the contact us portion of the page but it was using outlook express for some reason and was too much b/s for a freak'n web...
  38. Thread: credentials

    by kbwk2mch
    Replies
    10
    Views
    793

    ?????? h= have, n= No, ac + A/C HNAC...

    ?????? h= have, n= No, ac + A/C
    HNAC


    Are you busting my balls or testing me?
  39. Replies
    19
    Views
    1,381

    Those ar pretty hard things to learn on-line. Try...

    Those ar pretty hard things to learn on-line. Try Wholesaler and factory training etc. for the electrical. You can read up on it but fir me it's a hands on kinda thing. I not to great at sheetmetal...
  40. Thread: credentials

    by kbwk2mch
    Replies
    10
    Views
    793

    I have submitted info for professional acces 2x's...

    I have submitted info for professional acces 2x's and still can't use. I haven't been told I'm Not qualified so what is the problem.....any Ideas?
  41. Replies
    14
    Views
    2,796

    Well their is expensive and JUNK and less...

    Well their is expensive and JUNK and less expensive JUNK. either way it's JUNK.
  42. Replies
    8
    Views
    774

    carrier can probbably get you a new pan....

    carrier can probbably get you a new pan. sometimes you can cut and cover real panel so no refrigerant recovery required. you could also shut unit off and dry and clean real well....If you know where...
  43. Replies
    8
    Views
    1,544

    tech added freon without checking for a leak???...

    tech added freon without checking for a leak??? If it's icing its an airflow problem, dirty coil, blocked vents, filter etc. or low charge again.
  44. Replies
    4
    Views
    557

    If it's a patio how about a retractable sunshade...

    If it's a patio how about a retractable sunshade for patio...If you keep the sun off the glass that way less heat gain. and you can enjoy the patio.
  45. Replies
    11
    Views
    1,187

    Get the guy a manual and let him tell you.lol...

    Get the guy a manual and let him tell you.lol
    Don't love them o'll timers......we don't have the time they had in the day to do tasks. Some bolts need to be torqued and some don't......this one...
  46. Most electricians don't understand hvac controll...

    Most electricians don't understand hvac controll wiring...don't ask me why just seems that way around here. I would get an hvac guy to install a fan relay or the previously mentioned option.
  47. Thread: Carrier 48TJ

    by kbwk2mch
    Replies
    20
    Views
    2,891

    cut the guy some slack he's got a job to do he...

    cut the guy some slack he's got a job to do he sounds inteligent enough. He knew enough to ask for help.
    I agree with two posts. 1 This is a bad design 2. you probbably have a humidity control...
  48. Replies
    4
    Views
    627

    Personally I don't like either brand "Boiler"

    Personally I don't like either brand "Boiler"
Results 1 to 48 of 123