Search:

Type: Posts; User: The_USC_2001

Page 1 of 7 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    2
    Views
    196

    From what we have been told by the local Daikin...

    From what we have been told by the local Daikin rep here, no. We have to add an additional control module if our customer wants discharge air temp.
  2. Replies
    10
    Views
    458

    My first day working in the HVAC field as a...

    My first day working in the HVAC field as a helper back in 90, the first call of the day was to go work on a AHU that spanned the whole penthouse of the building it served. The shave on the blower...
  3. Replies
    2
    Views
    227

    Sounds like you have an OEM module that ALC made...

    Sounds like you have an OEM module that ALC made specifically for a manufacture. Looking at the ME812u module that ALC dealer use, there is not an error code 7. The error codes or as follows.

    The...
  4. Have these modules been downloaded before? I...

    Have these modules been downloaded before? I would imagine they have being they are a much older generation module that what we have now. If they have been downloaded, were they downloaded with an...
  5. Thread: Slum Lord

    by The_USC_2001
    Replies
    30
    Views
    2,981

    I was not referring to you. I am referring to the...

    I was not referring to you. I am referring to the land lord. Sorry if you thought I was talking about you.

    I am just saying that if a person wants to make money by renting out a home they own...
  6. Thread: Slum Lord

    by The_USC_2001
    Replies
    30
    Views
    2,981

    If you are not going to fix things like this...

    If you are not going to fix things like this properly then you have no business being a landlord IMO.
  7. It will work even is you do not change the module...

    It will work even is you do not change the module from a zn341v+ to a zn141v+. They both use the same driver.


    Sent from my iPhone using Tapatalk Go GAMECOCKS!!!!!!
  8. I am assuming you are not using more than 1 of...

    I am assuming you are not using more than 1 of the 3 DO's on the module. That would be the only issue.
  9. Replies
    6
    Views
    493

    This

    This
  10. They should still have the WebCTRL instillation...

    They should still have the WebCTRL instillation disk and license file. You could always get another computer and install WebCTRL on it. Then try and retrieve the user files from the old hard drive....
  11. As long as the ALC dealers use the latest...

    As long as the ALC dealers use the latest programing available, from here on out, all new ALC jobs should have BACnet setpoints as ALC has changed the setpoint microblock to be BACnet. It is up to...
  12. The zone temp should be able to be read. If you...

    The zone temp should be able to be read. If you can look at the logic page of the control program in WebCTRL and click on the RS microblock you should see a network visible checkbox. If it is not...
  13. Until recently when the ZS sensors were released,...

    Until recently when the ZS sensors were released, the setpoints were not bacnet. So I doubt you will get those unless programing changes are made in the ZN551.
  14. Replies
    1
    Views
    222

    When we integrate with a 3rd party device we can...

    When we integrate with a 3rd party device we can access what we integrate with using the first party. For example say we have a Trane Chiller that has a factory controller in it that talks BACnet. We...
  15. Replies
    10
    Views
    1,053

    The ALC guys in Atlanta referred to them as...

    The ALC guys in Atlanta referred to them as sponge bob's from the get go. That's where we got the term from.
  16. I have seen a trend lately of system leaning more...

    I have seen a trend lately of system leaning more toward BACnet than LON here is SC.
  17. Replies
    8
    Views
    590

    ALC discontinued the SE6104 and replaced it with...

    ALC discontinued the SE6104 and replaced it with the SE6104a. My understanding is they did this so the layout would be similar to some other modules and they could do away with one of the set-up's in...
  18. Thread: Can2Go

    by The_USC_2001
    Replies
    37
    Views
    6,616

    We are looking at picking up this product line. A...

    We are looking at picking up this product line. A Co-Worker and I will be going to a training class this week in Orlando. Look like a nice product to offer.
  19. Replies
    9
    Views
    714

    I just did not want him to think that all they...

    I just did not want him to think that all they had to do was apply an update and it would make the set points bacnet.

    I will say the new sensors are way overdue as well as the bacnet Setpoint...
  20. Replies
    9
    Views
    714

    While ALC did release these yesterday with the...

    While ALC did release these yesterday with the new ZS sensors, it will not help on anything existing unless the ALC programs are altered to include the new microblocks.
  21. Replies
    9
    Views
    1,173

    Quality HVAC guys have a edge on everyone else...

    Quality HVAC guys have a edge on everyone else when it comes to getting a control job. It is a lot easer to teach a HVAC tech the computer side than to teach a cumputer guy the HVAC side.

    That's...
  22. Replies
    9
    Views
    714

    Setpoints are not writable via bacnet unless...

    Setpoints are not writable via bacnet unless extra programing is done in the ALC module.
  23. Replies
    5
    Views
    479

    Yes he is

    Yes he is
  24. Replies
    106
    Views
    6,948

    Back before I moved into controls and was an hvac...

    Back before I moved into controls and was an hvac service tech I worked at a large mechanical contractor company here. At that company most of the sheet metal guys were in the sheet metal union. By...
  25. Replies
    106
    Views
    6,948

    I don't see how they could force a Wal-Mart union...

    I don't see how they could force a Wal-Mart union nationwide. In my state, South Carolina, we are a right to work state. No employer in SC can force employees to join a union. All unions work forces...
Results 1 to 25 of 155
Page 1 of 7 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event