  1. Replies
    5
    Views
    1,035

    I only have a couple of modules at the moment so...

    I only have a couple of modules at the moment so I quickly replaced the old keys for new and changed the address' to suit and everything seems to be working ok.

    Many Thanks

    Gareth
  2. Replies
    5
    Views
    1,035

    Siemens MBC Module Addressing

    I think you have cracked it. Would I be correct in saying that the old keys were white lettering on a blue back ground and the new keys are black lettering on a blue background? I see that I have a...
  3. Replies
    5
    Views
    1,035

    Siemens MBC Module Addressing

    I would appreciate some help on the addressing of MBC Modules. I have a single MBC, a few modules and two DPUs. The system is not connected to anything at the moment so it can be switched on /off...
  4. Replies
    4
    Views
    1,358

    Siemens Apogee Insight DPU

    Thanks

    I've am now able to bring the DPU's online and program the I/O.

    Many thanks once again. Just have to get up to speed with PPCL now.

    Gareth
  5. Replies
    4
    Views
    1,358

    Siemens Apogee Insight DPU

    Hi there Dingman

    I've since found that Lan (Trunk) 1 on the Open processor module is suspect as I connected a second DPU to Lan (Trunk) 2 and then used the DPU/MPU search facility on the system...
  6. Replies
    4
    Views
    1,358

    Siemens Apogee Insight DPU

    I want to connect a recovered DPU (12in / 12 out) to an existing MBC. I am still running NT4 +SP6 and Insight 3.2 and the size of the system does not justify upgrading to the current version of...
  7. Replies
    14
    Views
    7,283

    Induction Units

    Hi

    I have attached a sheet showing the basic operation of the unit. If you want more contact me direct and I can mail more sheets to you.

    Gareth
  8. Replies
    14
    Views
    7,283

    Induction system HVAC

    We have a system here in a building built in the 70's which worked very well, it would keep an office on the perimeter of the building i.e. 50% glass in the outside wall and OAT up to 35deg C to...
  9. Replies
    6
    Views
    2,166

    Siemens TEC Configuration

    Hi there

    Siemens here in RSA is the Siemens that deals with the Industrial S5/S7 etc PLCs.

    The company that deals with the Insight etc here, is really only an import agency dealing with a...
  10. Replies
    6
    Views
    2,166

    Siemens Apogee TEC configuration

    Hi there

    Tried as you suggested and it works 100%. I don't remember being able to do that when I was actually involved a few years ago with the Insight system.

    Many thanks

    Gareth
  11. Replies
    6
    Views
    2,166

    Siemens Apogee TEC configuration

    Hi there

    Done, it's surprising what one forgets when you are away for a couple of years.

    Many thanks

    Gareth
  12. Replies
    6
    Views
    2,166

    Siemens Apogee TEC configuration

    I have been away from HVAC controls for a number of years (retired) but have just been given some Siemens Insight equipment to play with tp keep the gray matter working.
    There is one MBC with Power...
  13. Replies
    134
    Views
    26,399

    Datamate

    If Datamate is available I would appreciate a copy also.

    My profie includes my email address.

    Thanks