Search:

Type: Posts; User: ACFIXR

Page 1 of 20 1 2 3 4

Search: Search took 0.05 seconds; generated 50 minute(s) ago.

  1. Replies
    40
    Views
    1,344

    That's our new "Green" model. 1000 seer rating as...

    That's our new "Green" model. 1000 seer rating as long as your windows are open and there's a breeze. Lifetime unlimited compressor warranty. Free filter change outs with your 199.99. Monthly peak...
  2. Replies
    56
    Views
    2,794

    Resurrected for general purposes. "Boss says...

    Resurrected for general purposes.

    "Boss says don't say anything bad about the box just fix it" :grin2:
  3. Replies
    26
    Views
    723

    I use to have customers that carried at home, and...

    I use to have customers that carried at home, and had spares in all the rooms too...................made me feel a little un-easy working at their homes. I made sure that I knocked really loud on the...
  4. Thread: Fire dampers

    by ACFIXR
    Replies
    11
    Views
    453

    Fire or smoke?

    Fire or smoke?
  5. Replies
    5
    Views
    347

    play with it some more......................

    play with it some more......................
  6. Replies
    326
    Views
    54,918

    Sticky: My 60th birthday

    535231

    The love of my life.
  7. Doug, where are these pics at now?

    Doug, where are these pics at now?
  8. Replies
    28
    Views
    2,107

    It's the MFM300. The original digital PT gauge....

    It's the MFM300. The original digital PT gauge. In this day and age nobody really needs a manifold anymore.

    http://www.cooper-atkins.com/products/mfm/
  9. Unless the manu has rated their product for up to...

    Unless the manu has rated their product for up to a specific footage. There are some dryers rated up to 45'. I know because I just did 23 units with higher rated EL'.:whistle:
  10. The bottom pic is a fine example of a...

    The bottom pic is a fine example of a "transition" duct.
  11. You really should research your daughters dryer...

    You really should research your daughters dryer brand and model# installation instructions. They will be specific as to what you can do. Some models can get the job done well and some some barely...
  12. Get your daughters dryer (Brand and model)...

    Get your daughters dryer (Brand and model) installation guide. Most driers are limited to a max footage. 25'<
  13. Thread: Magic Formula

    by ACFIXR
    Replies
    13
    Views
    770

    This can be interpolated using known published...

    This can be interpolated using known published values provided by the equipment manufacturer.
    TVA is an authority that dictates it's own design return air dry bulb.(75*) The rest of the country uses...
  14. Replies
    28
    Views
    1,392

    In a nutshell= PSC's draw less power (current/...

    In a nutshell=

    PSC's draw less power (current/ amps) when pressure is increased.
    ECM's draw more power (current/ amps) when pressure is increased.
  15. Replies
    28
    Views
    2,107

    For you guys that are looking for Cooper probes I...

    For you guys that are looking for Cooper probes I find them on Ebay. I bought a used SH66 and it had 4 probes in it. They look like they were never taken out of the case. $50.00 investment.$200.00...
  16. Replies
    28
    Views
    1,392

    Thanks for this explanation. So it's all about...

    Thanks for this explanation. So it's all about torque.
    Question for you Saturatedpsi: When at higher elevations air is less dense. When an ECM is programmed for torque at <2000' will it try to...
  17. Replies
    28
    Views
    1,392

    ECM's draw the required power to maintain rpm's....

    ECM's draw the required power to maintain rpm's. Higher or lower depending on static.
  18. Replies
    34
    Views
    1,913

    That's why you should use...

    That's why you should use spiral...............................
  19. Replies
    28
    Views
    1,392

    There is no increased volume with a restricted...

    There is no increased volume with a restricted duct. The restriction causes the ecm to draw more current to maintain it's rpm's. With more current comes more watts.With more watts comes more heat....
  20. Replies
    28
    Views
    1,392

    "The ECM is a DC motor, with a permanent magnet...

    "The ECM is a DC motor, with a permanent magnet
    rotor. Motor windings (electro-magnets) are placed
    around the rotor. An internal microcontroller
    sequentially connects DC current to each winding,...
  21. Replies
    28
    Views
    1,392

    "If the speed/torque relationship is incorrect...

    "If the speed/torque relationship is incorrect for the
    required airflow, the motor control can increase or decrease the torque (current) to
    the motor. This will in turn increase or decrease the...
  22. Replies
    18
    Views
    2,639

    Looks like an HVAC techs first plumbing solder...

    Looks like an HVAC techs first plumbing solder job, after brazing a couple 1000 joints using a rosebud while having a cool one on a sunday afternoon during a halftime show with a leaking shutoff...
  23. You don't need 28" to service a cleaneffects the...

    You don't need 28" to service a cleaneffects the perm filter is flexible. How bad do you want the aircleaner?.
  24. Replies
    17
    Views
    855

    http://i1201.photobucket.com/albums/bb359/Chuck_Ph...

    http://i1201.photobucket.com/albums/bb359/Chuck_Phelan/HVAC/carnac.jpg

    The great Carnac says .............I see a failed TXV in your future.....................
  25. Replies
    57
    Views
    1,864

    Your "comfortable" on a design day would be...

    Your "comfortable" on a design day would be adjusted to say 60* instead of 70*
  26. Replies
    49
    Views
    1,402

    Obviously you are ok. You should have put the...

    Obviously you are ok. You should have put the spare on and went to work. You probably will be looking for work soon.

    That was a separation, and the tire was out of balance before it...
  27. Replies
    9
    Views
    691

    What kind of gas do you have?

    What kind of gas do you have?
  28. Replies
    35
    Views
    3,099

    Nice job. What was your final tesp and rise?

    Nice job.
    What was your final tesp and rise?
  29. Replies
    128
    Views
    5,786

    2X ...

    2X

    http://i1201.photobucket.com/albums/bb359/Chuck_Phelan/HVAC/heat.jpg
  30. Replies
    20
    Views
    1,119

    Most standard curbs are 14". I always thought for...

    Most standard curbs are 14". I always thought for "snow loaded roofs" 14" was the minimum.
    As far as rain goes here in AZ. We can get 1/2 of our annual rainfall in a couple of hours, fills up a...
  31. Replies
    34
    Views
    1,913

    Vinster. Your referring to the exposed spiral on...

    Vinster. Your referring to the exposed spiral on my Facebook page.I used all thread and shallow strut to hang that pipe because it had some acute angles and sharp slopes as well as large registers...
  32. Replies
    20
    Views
    1,119

    Actual curb height was about 4". Then the rail...

    Actual curb height was about 4". Then the rail hangs over the edge of the curb,typically about 2 & 1/2".
  33. Replies
    17
    Views
    1,373

    damnfunnyyyyyyyyyyyyyyyyyyyyyy

    damnfunnyyyyyyyyyyyyyyyyyyyyyy
  34. Replies
    34
    Views
    1,913

    X2 -This what I typically do when I can. I...

    X2 -This what I typically do when I can.

    I like the way air flows thru pipe............
    ...
  35. Replies
    17
    Views
    1,373

    16 foot drop. Reservoir intact. Motor bolts...

    16 foot drop. Reservoir intact. Motor bolts popped out.
  36. Replies
    17
    Views
    1,373

    I just dropped my old pump off of a roof, onto a...

    I just dropped my old pump off of a roof, onto a concrete sidewalk. I almost think that I did it on purpose cause I am a new owner of a TZ8. :grin2:Which by the way is the second to last one that is...
  37. Replies
    20
    Views
    1,119

    Never,never, ever cut rafters! Always use headers...

    Never,never, ever cut rafters! Always use headers with hangers and sisters!

    I do all of my own roof penetrations on remodels. But I have close to 35 years of building experience so I have a little...
  38. Replies
    33
    Views
    3,743

    "The facility is down sizing and we only use half...

    "The facility is down sizing and we only use half of that coil"
  39. Replies
    33
    Views
    3,743

    The block of wood is to prevent "ponding" :grin2:

    The block of wood is to prevent "ponding" :grin2:
  40. Thread: Tachometer

    by ACFIXR
    Replies
    19
    Views
    1,286

    http://i1201.photobucket.com/albums/bb359/Chuck_Ph...

    http://i1201.photobucket.com/albums/bb359/Chuck_Phelan/HVAC/HVAC_Tools/rpms.jpg

    I use an Extech. It's cheap, $150-200. I use it verify exhaust fans and 3 phase blowers. If you don't know rpm's...
  41. Thread: I spy

    by ACFIXR
    Replies
    10
    Views
    668

    horse****......................

    horse****......................
  42. Replies
    70
    Views
    2,495

    Attention all hvac students. The class on heat...

    Attention all hvac students. The class on heat transfer will be starting soon. Please take your seats and pay attention.
    :munching:
  43. Replies
    1
    Views
    217

    Can you imagine the rash that stuff could give...

    Can you imagine the rash that stuff could give you!
  44. Replies
    22
    Views
    950

    Your an hvac tech, figure it...

    Your an hvac tech, figure it out.........................
  45. TXV's that had sae threads on the power heads...

    TXV's that had sae threads on the power heads instead of metric.:gah:
  46. Replies
    130
    Views
    4,718

    Smart is as smart does,.

    Smart is as smart does,.
  47. Replies
    7
    Views
    432

    Thanks. Mesquite smoked in my custom smoker. That...

    Thanks. Mesquite smoked in my custom smoker. That bird went to my favorite counter guy last Thanksgiving.
  48. Replies
    15
    Views
    3,370

    Unit has that cool green textured look from the...

    Unit has that cool green textured look from the 60's.
  49. Replies
    15
    Views
    3,370

    I found one yesterday with this monster boiler on...

    I found one yesterday with this monster boiler on it. I will post some more pics of it when I demo it. Asbestos and all....:grin2:
    ...
  50. Heck, there's companies here in Tucson doing that...

    Heck, there's companies here in Tucson doing that today......................:gah:
Results 1 to 50 of 1000
Page 1 of 20 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event