Search:

Type: Posts; User: TwinScrew

Search: Search took 0.00 seconds.

  1. Replies
    3
    Views
    668

    What package did you buy.. USB-TKIT (Virtual...

    What package did you buy.. USB-TKIT (Virtual BACview), Handheld BACView, or the iVu Tech Tools DVD?
  2. Replies
    10
    Views
    2,126

    Al/Al (Microchannel/Novation) Cond. Coil, or...

    Al/Al (Microchannel/Novation) Cond. Coil, or Al/Cu?
  3. Thread: Furnaces

    by TwinScrew
    Replies
    15
    Views
    810

    http://en.wikipedia.org/wiki/Furnace

    http://en.wikipedia.org/wiki/Furnace
  4. Replies
    45
    Views
    3,865

    I'm all for a Chiller Forum as well, if it counts...

    I'm all for a Chiller Forum as well, if it counts whatsoever.
  5. Replies
    2
    Views
    1,228

    The accurator for the 38HDF should be at the...

    The accurator for the 38HDF should be at the Condensing Unit.

    Do you have the KMC/HDF split, or QNC/HDF split?

    You are likely looking at the QNC/HDF split's installation instructions.
  6. Replies
    9
    Views
    1,556

    Or by being hit with a basketball ;). Carrier...

    Or by being hit with a basketball ;).

    Carrier has them on many of their R-410A RTU's & Air-Cooled Chillers now.
  7. Replies
    8
    Views
    5,112

    From Carrier's N-Coil Installation Manual: "4....

    From Carrier's N-Coil Installation Manual:

    "4. Coils that overhang (wider than furnace) do not require a transition in downflow application. However, a field-supplied furnace shelf should be...
  8. Replies
    2
    Views
    544

    A link to your average WSHP Service Manual: ...

    A link to your average WSHP Service Manual:

    http://www.docs.hvacpartners.com/idc/groups/public/documents/techlit/50r-5si.pdf

    I'd recommend getting your Post Count up and applying for "Pro...
  9. Replies
    18
    Views
    2,574

    That would be the Return Air Sensor....

    That would be the Return Air Sensor.
    http://www.forwardthinking.honeywell.com/products/wireless/focus_pro/focus_pro_feature.html
  10. Replies
    2
    Views
    2,101

    Is that one of the old Multi-Zones?

    Is that one of the old Multi-Zones?
  11. Replies
    11
    Views
    1,979

    Nice job, tech!

    Nice job, tech!
  12. Replies
    6
    Views
    993

    ^ What I don't understand, is that they have...

    ^ What I don't understand, is that they have R-134a Centrif's in Europe, but have not yet brought them over. What's unfortunate for them, is that on many plan/spec. jobs, they are not allowed to bid...
  13. Replies
    76
    Views
    17,199

    Where I am from, low ambient operation is quite...

    Where I am from, low ambient operation is quite frequent...

    With Carrier/Bryant residential-type condensing units, you have 2 options:

    - Cooling to 0F requires a Low Ambient Pressure Switch.
    -...
  14. Replies
    4
    Views
    1,289

    You can still get 38HDL down there? Must have...

    You can still get 38HDL down there?
    Must have some old stock kicking around, because they are definitely out of production.
  15. Replies
    16
    Views
    1,076

    That's how I got taken... was my first month of...

    That's how I got taken... was my first month of college in the 'big city', and was unbelievably naive... had 'sucker' written on my forehead. An absolute life lesson I'll never forget.

    The last...
  16. Replies
    4
    Views
    1,289

    Hi Peter, You are referring to the 38HDL...

    Hi Peter,

    You are referring to the 38HDL model. Unfortunately, these are now obsolete.

    Is this an existing system that needs a replacement condensing unit? Ductless Split?

    If you need to...
  17. Replies
    24
    Views
    1,255

    Souper just kicked my ass haha.

    Souper just kicked my ass haha.
  18. Replies
    98
    Views
    11,706

    Just saw this now: Congrats on the new job! If...

    Just saw this now:

    Congrats on the new job! If for some reason it doesn't work out, drop me a line.
  19. I have heard that they will no longer be...

    I have heard that they will no longer be importing 80%-er's into Canada - can anyone else confirm?
  20. Replies
    11
    Views
    3,523

    Always trust a professional.

    Always trust a professional.
  21. Replies
    11
    Views
    3,523

    Yes, it will work. That T-stat has the...

    Yes, it will work.

    That T-stat has the following capabilities:

    "Thermidistat Control
    - Heat pump 2-stage or Hybrid Heat 3-stage heat / 2-stage cooling with humidity control
    - Humidity...
  22. Replies
    5
    Views
    1,313

    That's correct! I just wanted to add that the...

    That's correct!

    I just wanted to add that the "5" is referring to 208/230-3-60... (same as the others).
  23. Replies
    6
    Views
    782

    Unfortunately, the RTU-MP controllers are not yet...

    Unfortunately, the RTU-MP controllers are not yet available for field-installation... would make it pretty easy.

    Also, I believe this unit is pre-ComfortLink...

    EDIT: I see this is an older VAV...
  24. Replies
    3
    Views
    2,028

    48TM Installation Instructions, for example:...

    48TM Installation Instructions, for example: http://www.commercial.carrier.com/commercial/hvac/technical_literature/1,3063,CLI1_CNT2_DIV12_ETI8619_MID4103_QRYY,00.html
  25. Unreal placement haha. As mentioned, they do have...

    Unreal placement haha. As mentioned, they do have their place if applied correctly.. but by the sounds of it, there wasn't much forethought put into it haha.

    Good luck w/ your new split!
Results 1 to 25 of 32