  1. Replies
    28
    Views
    1,003

    I got to roll with Osiyo on this one. As far as...

    I got to roll with Osiyo on this one. As far as paying sparky, I know we exclude any power wiring. No reason not to plan and submit for enough transformers. If it's an extra then everybody gets paid.
  2. Replies
    13
    Views
    726

    You are pretty much just making up air that is...

    You are pretty much just making up air that is being sucked out of the building. The temperature control doesn't have to all that great. A 5 degree dead band between heating and cooling should be...
  3. Replies
    13
    Views
    726

    You are pretty much just making up air that is...

    You are pretty much just making up air that is being sucked out of the building. The temperature control doesn't have to all that great. A 5 degree dead band between heating and cooling should be...
  4. Replies
    5
    Views
    278

    Hey to the Reaper! A lot of talent here.

    Hey to the Reaper! A lot of talent here.
  5. Thread: 3D Floorplans

    by mechdorn
    Replies
    13
    Views
    865

    Engineering Toolbox.... I'd suggest to stay away...

    Engineering Toolbox.... I'd suggest to stay away from duct layouts.
  6. Replies
    9
    Views
    323

    All inputs and outputs are defined as enumerated...

    All inputs and outputs are defined as enumerated automatically. Anything other than true/false in considered enumerated. A custom I/O can be defined as a booleen, or a two state true/false. Most...
  7. Thread: 3D Floorplans

    by mechdorn
    Replies
    13
    Views
    865

    Free is for me, the pro version offers other...

    Free is for me, the pro version offers other software programs, mostly for presentation. As far as plugins, I have one installed for piping. The on board tools are more powerful then meets the eye....
  8. Thread: 3D Floorplans

    by mechdorn
    Replies
    13
    Views
    865

    Thanks, I know how you feel. When I try to change...

    Thanks, I know how you feel. When I try to change something in a A-CAD file, it's like puling teeth. I have no clue and just run away.
  9. Thread: 3D Floorplans

    by mechdorn
    Replies
    13
    Views
    865

    I use it a lot. There are plenty of plugins and...

    I use it a lot. There are plenty of plugins and tutorials available on the internet. Speed is the key. Learning the keyboard functions is a must. Knowing when to stop is important. I try to keep it...
  10. Replies
    19
    Views
    621

    It's not the manufacturer that supply's the...

    It's not the manufacturer that supply's the device ID it's the programmer. So if you have multiple devices with same device ID it was the programmer that messed this up. For me every device receives...
  11. Please Let me backup on my power wiring...

    Please Let me backup on my power wiring statement. Any line voltage 277v or 120v is provided by the EC. These types of vav have electric heat or a fan, sometimes both. 99% of the the contain a small...
  12. We can't talk $$$ here... Maybe one of the...

    We can't talk $$$ here... Maybe one of the moderators can push this to the pro forum. Even with that, labor cost are very regional, most of the people here are not going to chime in on a blind quote....
  13. Replies
    23
    Views
    1,817

    How the heck did you do that? The program is long...

    How the heck did you do that? The program is long gone, I'm hoping you have that. The firmware version shouldn't be a big deal. JCI post them on a couple of their websites, if you don't have access...
  14. Replies
    23
    Views
    1,817

    I've programmed hundreds of these guys, so here...

    I've programmed hundreds of these guys, so here is what I know. 900 = Ultra slow, 360 = slow, 180 = medium, 90 = fast, 60 and down = ultra fast. If you can't control within the 360 to 90 range reset...
  15. Replies
    23
    Views
    1,817

    That is totally not true, you just don't have to...

    That is totally not true, you just don't have to deal with the conversions.
  16. Replies
    5
    Views
    192

    This is something that has popped up a couple of...

    This is something that has popped up a couple of times now, I saw another post saying that all of the trends are in Central time. Each claiming the platform time was set to something else. No answers...
  17. Replies
    4
    Views
    525

    I used the one Kele sells, it fixed my problem. I...

    I used the one Kele sells, it fixed my problem. I didn't think it was overly priced, about the same as a small field controller.
  18. Yeah, I looked at my stuff today, nothing was...

    Yeah, I looked at my stuff today, nothing was changed. I remember the first time we did this, I think we had the same problem. It was the plugs within the unit. We plugged one into the wrong spot....
  19. You need to set some of the controlling points to...

    You need to set some of the controlling points to "out of service". Any of the points that are being used as "BAS" the corresponding on board point needs to be turned off. I think the out service tag...
  20. Replies
    4
    Views
    448

    You have to to setup a user with the Hx Nav view....

    You have to to setup a user with the Hx Nav view. Then use one of the HX graphics, set a new view on the points folder, add the graphic as a Hx view not a Px view. I've done a few, just to try it,...
  21. Most of the controls people here use Visio, not...

    Most of the controls people here use Visio, not all, some use A-CAD. It depends on what you are most comfortable with. There has been countless post of people exchanging Visio files. Just do a site...
  22. Replies
    6
    Views
    378

    I would think the only providers of this type of...

    I would think the only providers of this type of info would be in a serious urban environment. I really don't think most weather feeds have the ability to provide this information. Try like central...
  23. Replies
    4
    Views
    277

    Once you apply the resource file. Close that...

    Once you apply the resource file. Close that portion, then open the JCI import manager. It's usually the default view if you double click the N2 network. From there it should automatically append the...
  24. Replies
    16
    Views
    962

    If it was my company I would align myself with a...

    If it was my company I would align myself with a known brand. At least one of them. Just for the sole purpose of not being closed out on a bid project. They all come with some annual cost, some a lot...
  25. Replies
    22
    Views
    756

    My opinion, your about to throw good money at an...

    My opinion, your about to throw good money at an antiquated device. Take that money and put towards a new front end.