    I guess that's about the easiest way to get it...

    I guess that's about the easiest way to get it done. More expensive than going direct, but a lot less than going onsite to figure things out. What a waste just to revive an old electric boiler that...
  2. Replies
    2
    Views
    148

    Johnson R26 step controller

    Hi all,

    Looking for the PDF file or wiring diagram of an old Johnson Controls step controller R26AB-9200. Can't find anything online, and jobsite is 5 hours away. Intent is to restrict operation...
  3. I would sugggest to install the sensor on a tee...

    I would sugggest to install the sensor on a tee in order to be able to bleed air easily. Install the sensor on the side port of tee with elbow to have sensor vertical, water line below, and drain...
  4. Replies
    15
    Views
    1,073

    I agree with WillyTech. Comm Tools is a...

    I agree with WillyTech. Comm Tools is a proprietary software for Siemens tech. Having to ask how to update job database with it leaves me puzzled. This is one of the basic things you should have been...
  5. Replies
    15
    Views
    1,073

    You need a new license code to unlock 3.11...

    You need a new license code to unlock 3.11 matching your dongle key SN#.
  6. Only 1 point is commanded per drive over MS/TP....

    Only 1 point is commanded per drive over MS/TP. It is a BV to allow drive to start. Drive to operate with local setpoint after that.

    We want to monitor feedback, alarm and drive running over...
  7. Drives are addressed from 101 to 109, so they are...

    Drives are addressed from 101 to 109, so they are in the master range.

    Any disadvantages from putting them in the slave range apart from having to configure manually the drives in the Delta panel?...
  8. Replies
    7
    Views
    615

    Have you tried to backup the database and then...

    Have you tried to backup the database and then restore it before rebooting your Insight server? Database fragmentation can cause loss of performance. Backup and restore will clean that.

    Can't...
  9. Wow, a lot of information that I will have to...

    Wow, a lot of information that I will have to check next time I go there. But it won't be before a least end of april, if not later.

    Really well explained. I will try to investigate what I can...
  10. ABB ACH-550 drive with BacNet integration to Delta Controls panel

    Does anybody had success with that kind of setup?

    Nine drives alone on MS/TP net of Delta Controls DSC panel. Takes about 3 minutes to get all the points of 1 drive. And almost no exchange between...
  11. Replies
    11
    Views
    1,027

    Yes, you're right. What I usually do is define...

    Yes, you're right. What I usually do is define one virtual digital point that will command two $loc variables. The $loc are used as toggle point in the OIP command.
  12. Replies
    11
    Views
    1,027

    I checked and subpoint 53 is not commandable...

    I checked and subpoint 53 is not commandable directly using its name, and cannot be used in graphics. It needs to be set with an OIP command in PPCL using a toggle point that you can use in your...
  13. Replies
    11
    Views
    1,027

    It's not all subpoints inside a TEC that can be...

    It's not all subpoints inside a TEC that can be commanded directly either with PPCL or through the front end (not using Global Commander). It needs to be unbundled to be available, and be among the...
  14. Replies
    15
    Views
    1,572

    Make sure the flag point is a digital virtual...

    Make sure the flag point is a digital virtual point. Also, try using flag = 1 or set(1,flag) Who knows... If it stil dosn't work, probably that point name is stuck somewhere inside controllers...
  15. Thread: Siemens

    by ynut204
    Replies
    19
    Views
    1,970

    VAV Controllers

    Maybe I missed it, but d_d_c_jci never mentionned that the controllers were TECs. With an Insight 2.X, might even be TCUs...
  16. Replies
    9
    Views
    878

    When you are in hyperterminal and trying to edit...

    When you are in hyperterminal and trying to edit PPCL, the panel is asking first for the line number, and then for the complete line as you want it to be after the change: line number, then a space,...
  17. Replies
    9
    Views
    878

    Apogee 3.2 is compatible with firmware 2.5 only...

    Apogee 3.2 is compatible with firmware 2.5 only if Hot Fix 1 is installed. But it is not compatible with 2.6 or higher. MECF won't work with 3.2 as far as I know, whatever the version.
  18. Thread: PPCL help?

    by ynut204
    Replies
    7
    Views
    1,401

    You can also see local variables from the Insight...

    You can also see local variables from the Insight Apogee interface. Run a Panel Point Log report: use program_name:* and check to have the field panels do the searching. You will get the actual value...
  19. Thread: Siemens Alarms

    by ynut204
    Replies
    4
    Views
    567

    If the points are still in the database, just...

    If the points are still in the database, just force them in manual alarm with the Commander application, then release them to normal condition. You shoud be able to acknowledge and delete them after...
  20. Replies
    4
    Views
    969

    I am currently working for Siemens. And did work...

    I am currently working for Siemens. And did work for other majors in the past. From my experience, and advice from Siemens techs here in Montreal, coming from every other control company (including...
  21. Thread: Temp Sensor

    by ynut204
    Replies
    5
    Views
    929

    The standard MEC doesn't take 100K ohm sensors....

    The standard MEC doesn't take 100K ohm sensors. Even if you can calculate a slope and intercept for it, it won't give a good reading, regardless of jumper position.
  22. Thread: Temp Sensor

    by ynut204
    Replies
    5
    Views
    929

    Depends on what type of controller from SBT you...

    Depends on what type of controller from SBT you are talking about. TEC can accept a 100K sensor, and 10K. MBC can take it too if you have a 100K module.
  23. Replies
    16
    Views
    2,053

    Your point may resides in a TEC controller or...

    Your point may resides in a TEC controller or another FLN device. If it's the case, it is driven locally in this controller by a built-in application. Or the point uses the same address as an other...
  24. Replies
    14
    Views
    5,616

    Yes, Datamate can backup Apogee panels. If your...

    Yes, Datamate can backup Apogee panels. If your version is not too old. Version 3 and above for sure, can't say for 2 and below.