04-17-2013, 07:46 PM
Thread: Johnson R26 step controller
by ynut204- Replies
- 2
- Views
- 148
I guess that's about the easiest way to get it...
I guess that's about the easiest way to get it done. More expensive than going direct, but a lot less than going onsite to figure things out. What a waste just to revive an old electric boiler that...
-
04-10-2013, 08:21 AM
Thread: Johnson R26 step controller
by ynut204- Replies
- 2
- Views
- 148
Johnson R26 step controller
Hi all,
Looking for the PDF file or wiring diagram of an old Johnson Controls step controller R26AB-9200. Can't find anything online, and jobsite is 5 hours away. Intent is to restrict operation... -
01-17-2013, 07:24 AM
- Replies
- 22
- Views
- 1,456
I would sugggest to install the sensor on a tee...
I would sugggest to install the sensor on a tee in order to be able to bleed air easily. Install the sensor on the side port of tee with elbow to have sensor vertical, water line below, and drain...
-
05-25-2012, 07:02 AM
Thread: Upgrade Insight 3.6
by ynut204- Replies
- 15
- Views
- 1,073
I agree with WillyTech. Comm Tools is a...
I agree with WillyTech. Comm Tools is a proprietary software for Siemens tech. Having to ask how to update job database with it leaves me puzzled. This is one of the basic things you should have been...
-
04-20-2012, 08:51 AM
Thread: Upgrade Insight 3.6
by ynut204- Replies
- 15
- Views
- 1,073
You need a new license code to unlock 3.11...
You need a new license code to unlock 3.11 matching your dongle key SN#.
-
03-26-2012, 09:35 PM
- Replies
- 17
- Views
- 1,133
Only 1 point is commanded per drive over MS/TP....
Only 1 point is commanded per drive over MS/TP. It is a BV to allow drive to start. Drive to operate with local setpoint after that.
We want to monitor feedback, alarm and drive running over... -
03-26-2012, 05:20 PM
- Replies
- 17
- Views
- 1,133
Drives are addressed from 101 to 109, so they are...
Drives are addressed from 101 to 109, so they are in the master range.
Any disadvantages from putting them in the slave range apart from having to configure manually the drives in the Delta panel?... -
03-22-2012, 07:49 PM
Thread: Siemens Insight extreamly slow response
by ynut204- Replies
- 7
- Views
- 615
Have you tried to backup the database and then...
Have you tried to backup the database and then restore it before rebooting your Insight server? Database fragmentation can cause loss of performance. Backup and restore will clean that.
Can't... -
03-22-2012, 07:17 PM
- Replies
- 17
- Views
- 1,133
Wow, a lot of information that I will have to...
Wow, a lot of information that I will have to check next time I go there. But it won't be before a least end of april, if not later.
Really well explained. I will try to investigate what I can... -
03-22-2012, 08:04 AM
- Replies
- 17
- Views
- 1,133
ABB ACH-550 drive with BacNet integration to Delta Controls panel
Does anybody had success with that kind of setup?
Nine drives alone on MS/TP net of Delta Controls DSC panel. Takes about 3 minutes to get all the points of 1 drive. And almost no exchange between... -
11-08-2007, 11:03 PM
Thread: Help with TEC App. 2281
by ynut204- Replies
- 11
- Views
- 1,027
Yes, you're right. What I usually do is define...
Yes, you're right. What I usually do is define one virtual digital point that will command two $loc variables. The $loc are used as toggle point in the OIP command.
-
11-08-2007, 08:49 PM
Thread: Help with TEC App. 2281
by ynut204- Replies
- 11
- Views
- 1,027
I checked and subpoint 53 is not commandable...
I checked and subpoint 53 is not commandable directly using its name, and cannot be used in graphics. It needs to be set with an OIP command in PPCL using a toggle point that you can use in your...
-
11-07-2007, 08:51 PM
Thread: Help with TEC App. 2281
by ynut204- Replies
- 11
- Views
- 1,027
It's not all subpoints inside a TEC that can be...
It's not all subpoints inside a TEC that can be commanded directly either with PPCL or through the front end (not using Global Commander). It needs to be unbundled to be available, and be among the...
-
10-29-2007, 05:01 PM
Thread: PPCL Programming
by ynut204- Replies
- 15
- Views
- 1,572
Make sure the flag point is a digital virtual...
Make sure the flag point is a digital virtual point. Also, try using flag = 1 or set(1,flag) Who knows... If it stil dosn't work, probably that point name is stuck somewhere inside controllers...
-
VAV Controllers
Maybe I missed it, but d_d_c_jci never mentionned that the controllers were TECs. With an Insight 2.X, might even be TCUs...
-
11-26-2005, 03:30 PM
Thread: Insight 3.2 with MEC controllers
by ynut204- Replies
- 9
- Views
- 878
When you are in hyperterminal and trying to edit...
When you are in hyperterminal and trying to edit PPCL, the panel is asking first for the line number, and then for the complete line as you want it to be after the change: line number, then a space,...
-
11-21-2005, 01:58 PM
Thread: Insight 3.2 with MEC controllers
by ynut204- Replies
- 9
- Views
- 878
Apogee 3.2 is compatible with firmware 2.5 only...
Apogee 3.2 is compatible with firmware 2.5 only if Hot Fix 1 is installed. But it is not compatible with 2.6 or higher. MECF won't work with 3.2 as far as I know, whatever the version.
-
09-14-2005, 04:41 PM
Thread: PPCL help?
by ynut204- Replies
- 7
- Views
- 1,401
You can also see local variables from the Insight...
You can also see local variables from the Insight Apogee interface. Run a Panel Point Log report: use program_name:* and check to have the field panels do the searching. You will get the actual value...
-
09-08-2005, 04:58 PM
Thread: Siemens Alarms
by ynut204- Replies
- 4
- Views
- 567
If the points are still in the database, just...
If the points are still in the database, just force them in manual alarm with the Commander application, then release them to normal condition. You shoud be able to acknowledge and delete them after...
-
08-19-2005, 07:45 AM
Thread: working for siemens or jci?
by ynut204- Replies
- 4
- Views
- 969
I am currently working for Siemens. And did work...
I am currently working for Siemens. And did work for other majors in the past. From my experience, and advice from Siemens techs here in Montreal, coming from every other control company (including...
-
05-12-2005, 09:10 PM
Thread: Temp Sensor
by ynut204- Replies
- 5
- Views
- 929
The standard MEC doesn't take 100K ohm sensors....
The standard MEC doesn't take 100K ohm sensors. Even if you can calculate a slope and intercept for it, it won't give a good reading, regardless of jumper position.
-
05-09-2005, 10:48 PM
Thread: Temp Sensor
by ynut204- Replies
- 5
- Views
- 929
Depends on what type of controller from SBT you...
Depends on what type of controller from SBT you are talking about. TEC can accept a 100K sensor, and 10K. MBC can take it too if you have a 100K module.
-
04-07-2005, 10:11 PM
Thread: Hiden Point On Siemens Insight
by ynut204- Replies
- 16
- Views
- 2,053
Your point may resides in a TEC controller or...
Your point may resides in a TEC controller or another FLN device. If it's the case, it is driven locally in this controller by a built-in application. Or the point uses the same address as an other...
-
04-07-2005, 09:58 PM
Thread: Backing up Siemens Apogee
by ynut204- Replies
- 14
- Views
- 5,616
Yes, Datamate can backup Apogee panels. If your...
Yes, Datamate can backup Apogee panels. If your version is not too old. Version 3 and above for sure, can't say for 2 and below.