Search:

Type: Posts; User: biggi

Page 1 of 3 1 2 3

Search: Search took 0.01 seconds.

  1. Thread: Manual D

    by biggi
    Replies
    7
    Views
    310

    Thanks all :-)

    Thanks all :-)
  2. Thread: Manual D

    by biggi
    Replies
    7
    Views
    310

    I have that and know how to use it. But how do I...

    I have that and know how to use it. But how do I figure out how much Cfm per room ect ect
  3. Thread: Manual D

    by biggi
    Replies
    7
    Views
    310

    Manual D

    I was wondering if there is a way I can size a duct layout with using a program such as Wrightsoft? Maybe a dumb question but I don't have the program.
  4. Thread: Goodman 14 seer

    by biggi
    Replies
    11
    Views
    819

    I'm getting .12 inwc on my supply side. Return is...

    I'm getting .12 inwc on my supply side. Return is directly under unit on inside wall so I have plenty of return air
  5. Thread: Goodman 14 seer

    by biggi
    Replies
    11
    Views
    819

    The mastic has dried it's good. It's just the...

    The mastic has dried it's good. It's just the cabinet keeps sweating and puddling on the stand.
  6. Thread: Goodman 14 seer

    by biggi
    Replies
    11
    Views
    819

    I haven't got in resolved yet. However, I was...

    I haven't got in resolved yet. However, I was there today and I believe I'm going to up grade a couple ducts to increase some flow. I have the blower on high adjusted the freon once again. Crossing...
  7. Thread: Ice o mastic

    by biggi
    Replies
    22
    Views
    1,395

    lol exactly what I did. Seems to be doing the job...

    lol exactly what I did. Seems to be doing the job now. We'll see in a day or so. Gremlins I tell ya gremlins !!
  8. Thread: Ice o mastic

    by biggi
    Replies
    22
    Views
    1,395

    We'll hear I sit with this pos again. Change comp...

    We'll hear I sit with this pos again. Change comp and still doing the same thing. So I got another TXV and low and behold it was working like a champ. For a day. SMH!!!
    It filled the bin and would...
  9. Thread: Goodman 14 seer

    by biggi
    Replies
    11
    Views
    819

    I've done every thing you said except the screw...

    I've done every thing you said except the screw heads but that makes sence too. I'm going over in the morning. It was raining when I finished up. So I wasn't able to properly check the charge either....
  10. Thread: Goodman 14 seer

    by biggi
    Replies
    11
    Views
    819

    Goodman 14 seer

    I just put this system in fri. The handler is in the garage. Granted I'm in Florida. And it's been raining here like clock work every day. Customer called me this morning say the handler was sweating...
  11. Thread: Ice o mastic

    by biggi
    Replies
    22
    Views
    1,395

    That was another thing I noticed to the comp was...

    That was another thing I noticed to the comp was sweating.
  12. Thread: Ice o mastic

    by biggi
    Replies
    22
    Views
    1,395

    Well with high suction and low discharge I was...

    Well with high suction and low discharge I was positive it was TXV. And comparing amp draw to data plate I didn't think it was compressor. But I guess I was wrong. It's been a couple years since I've...
  13. Thread: Ice o mastic

    by biggi
    Replies
    22
    Views
    1,395

    Yes I'm not a fan either. I'm used to hoshi and...

    Yes I'm not a fan either. I'm used to hoshi and manis. I checked purge it's not leaking by. Water temp is mid 74. Coming in. Water in res gets down to 34 no lower. And no ice forms
  14. Thread: Ice o mastic

    by biggi
    Replies
    22
    Views
    1,395

    Model ICE 0400FA4

    Model ICE 0400FA4
  15. Thread: Ice o mastic

    by biggi
    Replies
    22
    Views
    1,395

    Ice o mastic

    Ok guys I'm lost. Got an ice o matic stand alone machine. Customer called cause it wasn't making ice. Get here. And I have a high suction 82 and a lower discharge 240. Ambient temp in here is about...
  16. Thread: Utility bed

    by biggi
    Replies
    5
    Views
    564

    Where is local for you? Lol

    Where is local for you? Lol
  17. Thread: Utility bed

    by biggi
    Replies
    5
    Views
    564

    Utility bed

    Does anyone know where to find these beds utility/service beds for small trucks ie Colorado nissan ranger. I've hunted for them online but no luck. I've seen them on the road so I know they exist...
  18. Thread: Motor and caps

    by biggi
    Replies
    6
    Views
    875

    Motor and caps

    Is there a way to test a motor to find out what the proper size cap it needs to run?
  19. Replies
    13
    Views
    1,084

    Yes both are new

    Yes both are new
  20. Replies
    13
    Views
    1,084

    I went ahead and by passed the dehumidifier....

    I went ahead and by passed the dehumidifier. Thinking it's bleeding back. So now I have straight pipe to condenser coil and straight line back from evap. Still the same issue. Ugh not having fun on...
  21. Replies
    13
    Views
    1,084

    It's the valve for the dehumidifier

    It's the valve for the dehumidifier
  22. Replies
    13
    Views
    1,084

    Bard 3.5 ton wall hung

    I posted before on this system. I replaced the cap tube assembly and txv. Weighed in the charge. I'm getting no SH. sub cool is 15. And I'm only getting a 10 degree split. I'm stumped. I'm back to...
  23. Thread: Bard wall hung

    by biggi
    Replies
    4
    Views
    484

    Do they make a replacement cap tube assembly for...

    Do they make a replacement cap tube assembly for those. I've built them before for other commercial units but didn't know they made them.
  24. Thread: Bard wall hung

    by biggi
    Replies
    4
    Views
    484

    Hit wrong button lol. Anyways. I seen 3 of the 5...

    Hit wrong button lol. Anyways. I seen 3 of the 5 caps tubes sweating 2 not sweating.
  25. Thread: Bard wall hung

    by biggi
    Replies
    4
    Views
    484

    Bard wall hung

    Ok guys here's one for you. Got a bard wall hung not cooling well. 85 out door 75 idwb super heat 35 sub cool 10. Txv metering device. 10 degree split temp. ????? Open the case and did see 2 out
  26. Replies
    1
    Views
    444

    Contractors lisence

    I've looked all over the place and I can not find a place or any information on how and/or where to take the the class/test to get my contractors lisence. I live in ocala Fl. Any info would be...
  27. Replies
    16
    Views
    1,591

    It sits in a square with four total condensers....

    It sits in a square with four total condensers. Condenser coil is clean. About 1.5 feet apart. It's a really bad set up. The units are about 6 years old. Coil is clean cause I cleaned them.
  28. Replies
    16
    Views
    1,591

    Comp is amping ok

    Comp is amping ok
  29. Replies
    16
    Views
    1,591

    52 is low side pipe temp. Yeah SC is high

    52 is low side pipe temp. Yeah SC is high
  30. Replies
    16
    Views
    1,591

    7.5 ton American standard

    Working on this unit customer says its not cooling like it should. I got 76 low side pressure 285 high side. Low side temp 52 high side 100. Got 100 degree entering dry bulb at condenser. I got a 14...
  31. Replies
    20
    Views
    1,945

    So is it normal for it to ice on the compressor...

    So is it normal for it to ice on the compressor side and ice half the head of the compressor?
  32. Replies
    20
    Views
    1,945

    I've never seen a CPR on a true case nor anywhere...

    I've never seen a CPR on a true case nor anywhere else. I've only been doing these small cases for little over a year. Been residential AC for over 15 years. I'm with a different company and they do...
  33. Replies
    20
    Views
    1,945

    First time on this brand. If it were a TRUE case...

    First time on this brand. If it were a TRUE case it would be fixed. I'm very familiar with them.
  34. Replies
    20
    Views
    1,945

    Just couldn't get suction line temp down past...

    Just couldn't get suction line temp down past about 45 to 50 degrees. I even opened the TXV but couldn't get pressure above 28
  35. Replies
    20
    Views
    1,945

    About 45 min fans never came on either in box

    About 45 min fans never came on either in box
  36. Replies
    20
    Views
    1,945

    It's a Howard/ McCray box

    It's a Howard/ McCray box
  37. Replies
    20
    Views
    1,945

    Box temp 65 no product in box, txv, 25 low side...

    Box temp 65 no product in box, txv, 25 low side 255 high side. SH was around 35. Didn't check SC but sight glass is full. It's 404a freon. That's about all I have. end of the day job you know
  38. Replies
    20
    Views
    1,945

    Three door reach in freezer

    Got this freezer in working on. I can't get the temp down. I noticed the crankcase pressure regulator was iceing on the comp side. This is a new freezer about a year old. I have never seen this on a...
  39. Replies
    33
    Views
    9,707

    Way to take this thread to the extreme guys lol....

    Way to take this thread to the extreme guys lol. Great post though I appreciate every reply
  40. Replies
    33
    Views
    9,707

    Thanks everyone. I swapped two terminals and it...

    Thanks everyone. I swapped two terminals and it was fine. It's been a long day no doubt summer has hit in FL. But is that the only way to tell if its wires correctly. There has to be a way to know...
  41. Replies
    33
    Views
    9,707

    3 phase ac compressor

    Just put a new comp in this unit roof top package. Wires everything up push contractor in and the comp comes on but not pumping. How do I know I have the wireing on the correct terminal? It's late...
  42. Replies
    7
    Views
    642

    Thanks mike ill look into that. Do you have to...

    Thanks mike ill look into that. Do you have to recover all the R12 or can you go in over top of it? Not that its that important . Cause this unit only holds 17 ounces.
  43. Replies
    7
    Views
    642

    Raetone reach in 47 cu ft freezer.

    Got this freezer the other day for a very fair price. Unfortunately it's R12. It had a leak it the cap tube. Easy fix. My question is.. Is there a drop in replacement for R12? I don't want to go...
  44. Replies
    19
    Views
    2,887

    YEP! see it all the time.

    YEP! see it all the time.
  45. Replies
    19
    Views
    2,887

    check voltage on start up. had 244volts didn't...

    check voltage on start up. had 244volts didn't drop any on start up. got 5kw heat in each pulling 20 amps per unit. but this jump is only on start up at the condensing unit. and only one is doing it....
  46. Replies
    26
    Views
    16,159

    what time is diner!

    what time is diner!
  47. Replies
    19
    Views
    2,887

    amp spike on carrier 5 ton heat pump

    so i installed 2 carrier 5 ton heat pump systems in a doctors office about a week ago. customer called today and said this is the first time the used to the heat and they tripped the main 200 amp...
  48. Replies
    10
    Views
    1,300

    it was under warranty. and swapping the motor...

    it was under warranty. and swapping the motor fixed the problem. it's all good now. thanks guys for the input.
  49. Replies
    10
    Views
    1,300

    it's an X13 motor

    it's an X13 motor
  50. Replies
    10
    Views
    1,300

    the motor has the low voltage triggers going...

    the motor has the low voltage triggers going directly to it. unhooked both fan and heat low voltage wires and fan still runs. nothing going to motor but high voltage and the low voltage common wire.
Results 1 to 50 of 127
Page 1 of 3 1 2 3

Related Forums

Plumbing Talks | Contractor MagazineThe place where Electrical professionals meet.
Quality Home Comfort Awards