Search:

Type: Posts; User: jeremyr325

Page 1 of 7 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    3
    Views
    305

    X2

    X2
  2. Replies
    7
    Views
    785

    (BAS-SVP06) Tracer™ UC400/UC600 with Tracer™ SC...

    (BAS-SVP06) Tracer™ UC400/UC600 with Tracer™ SC System Controller Programming Guide
    Could I get a copy of that also thanks
  3. Replies
    1
    Views
    269

    Superheat and subcooling

    I would like to start a thread discussing scenos using subcooling and superheat. Like what problems would happen with different thing such as 98 OA AND 87 indoor temp. What to except and similar...
  4. www.venstar.com/Support/Manuals/TIB-515TraneInterf...

    www.venstar.com/Support/Manuals/TIB-515TraneInterfaceBoardRev1.pdf
  5. Thread: Yaskawa VFD

    by jeremyr325
    Replies
    0
    Views
    170

    Yaskawa VFD

    What is the difference in the z1000 drives and the v1000 drives
  6. Replies
    7
    Views
    368

    I really like Carrier controls. The open protocol...

    I really like Carrier controls. The open protocol not ccn. They have very good documentation. That means a lot. They are made by ALC with has been around for a long time and make a lot of controls...
  7. Replies
    41
    Views
    962

    I second that. That is the most ignorant thing I...

    I second that. That is the most ignorant thing I have ever heard.
    Any time you open the system you should change drier.
    Are you unloading the system?
  8. Replies
    41
    Views
    962

    WHAT??????????

    WHAT??????????
  9. Replies
    41
    Views
    962

    Can you get a supply grill count and what size...

    Can you get a supply grill count and what size the lines are. Also what size is the main trunk after the two furnaces. How are the twined together. I have seen more than once the two blowers don't...
  10. Replies
    41
    Views
    962

    Airflow

    Airflow
  11. Replies
    30
    Views
    1,287

    Instand.com

    Instand.com
  12. Replies
    9
    Views
    401

    Has anyone used this software

    Has anyone used this software
  13. Replies
    1
    Views
    226

    I have installed 5 of these systems. Is this...

    I have installed 5 of these systems. Is this system on a system controller? Do they have a wired controller. If so have you changed the setting to use the sensor in the wired controller.?
  14. Replies
    10
    Views
    394

    Should wrk fine on windows 7

    Should wrk fine on windows 7
  15. Replies
    10
    Views
    394

    Try app loading it before replacing. It has got...

    Try app loading it before replacing. It has got me out of a lot of jams do you have app loader. I can send you the file for a rtu open
  16. Replies
    10
    Views
    394

    X2 and zs sensors

    X2 and zs sensors
  17. Replies
    10
    Views
    394

    But the latest driver in it. I would app load it.

    But the latest driver in it. I would app load it.
  18. Replies
    1
    Views
    188

    Orion Controls

    Does any one know what kind of cable you need to interface with orion controls using Prism II
  19. Thread: Fluke 9040

    by jeremyr325
    Replies
    8
    Views
    400

    How do you know if your rotation is backwards. It...

    How do you know if your rotation is backwards. It looks like that it shows arrows ccw or cw. The first things that I will use it on is a new screw chiller.
  20. Thread: Fluke 9040

    by jeremyr325
    Replies
    8
    Views
    400

    I am not talking about some small package unit or...

    I am not talking about some small package unit or split system. I am talking about bigger chiller scroll , screw and centfi
  21. Thread: Fluke 9040

    by jeremyr325
    Replies
    8
    Views
    400

    Fluke 9040

    Has anyone used this rotation meter. How does it know if the rotation is right. According to the manual it gives a arrow indicating the rotation. How is that supposed to help on a scroll. You don't...
  22. Thread: Viso again

    by jeremyr325
    Replies
    11
    Views
    1,513

    I would like to have some stencils if any one...

    I would like to have some stencils if any one don't mind. Thanks
  23. Replies
    3
    Views
    294

    Could I add it too the factory writen program for...

    Could I add it too the factory writen program for the rtu in equipment builder
  24. Replies
    3
    Views
    294

    Lead / lag rtu"s

    I have a paint/baking room at a factory we do work at. They have got two 25 ton units feeding this room. (Big room), One unit will keep uo most of the time until middle of summer. Is the a control...
  25. Thread: Vvt or vav

    by jeremyr325
    Replies
    5
    Views
    463

    No this is a ceiling return. Would you recommend...

    No this is a ceiling return. Would you recommend a vfd?
Results 1 to 25 of 164