Search:

Type: Posts; User: victork1998

Search: Search took 0.00 seconds.

  1. Finally got a system that is 13 eer and 16 seer....

    Finally got a system that is 13 eer and 16 seer. The owner of the HVAC company is still confused and thinks that the e-motor will qualify the furnace for the rebate. I'd like to thank everybody for...
  2. Quote "If your installed combination does not...

    Quote "If your installed combination does not have an ARI certificate, you do not get the tax credit. It is that simple. Something scribbled on the receipt won't cut it."
    Is an ARI certified ref #...
  3. Sorry, I misunderstood the issue. So I still need...

    Sorry, I misunderstood the issue. So I still need one air intake pipe and one exhaust pipe? He only connected to the old 3" horizontal exhaust pipe.
  4. John, thanks very much for pointing out the...

    John, thanks very much for pointing out the importance of AHRI certified ref #. It is too late for my first unit. For the second unit, I will request them to put in the following combination that has...
  5. Thanks for the web site. According to that, 16...

    Thanks for the web site. According to that, 16 seer or higher central AC qualifies for the tax credit. Not sure about the need for a complete system. Rheem also gives "Proof of Qualified Energy...
  6. Are you sure that I will not get the tax credit?...

    Are you sure that I will not get the tax credit? I was told by the dealer that I qualify for the $1500 tax credit in the contract. The dealer also guarantees that I will get $2000 Rheem rebates. Does...
  7. Thanks very much. A transition was made and the...

    Thanks very much. A transition was made and the unit looks funny: Big top smaller bottom. I think I have enough space in the basement, so air intake pipe is probably not necessary. For the attic, the...
  8. Cased coil much wider than furnace? Air intake pipe?

    Hi, I am having two old systems replaced with Rheem. One has been installed. I have a few questions. 1): The cased coil (RCQD for the 3 ton RARL JEZ 036) is about 6-7" wider than the furnace (RGFD07,...
  9. Replies
    11
    Views
    1,433

    Definitely will get a good local contractor to...

    Definitely will get a good local contractor to install it. Not now when they are all busy.
  10. Replies
    11
    Views
    1,433

    How about a Goodman unit? Much lower priced. Like...

    How about a Goodman unit? Much lower priced. Like 96% two stage furnace and 15 seer AC unit only cost just above 2 grand (E-bay). Almost less half what Trane charges. Don't know the quality tough.
  11. Replies
    11
    Views
    1,433

    Thanks. I am having a local contractor coming...

    Thanks.

    I am having a local contractor coming to replace the motor, capacitor and checking/charging pressure. It is raining here and that keeps him from coming. He said he wants to measure the...
  12. Replies
    11
    Views
    1,433

    Hi, thanks. The motor is a single shaft...

    Hi, thanks.

    The motor is a single shaft sitting on top. I noticed it was running intermittently two, three days ago. It stopped working completely now. It was down for only a couple of days. Hope...
  13. Replies
    11
    Views
    1,433

    My 18 years old Magic Chef Central AC outside fan...

    My 18 years old Magic Chef Central AC outside fan motor just stopped working. It is a Westinghouse brand. Could not figure out the model number or horse power. The label says the following: S#...
  14. Replies
    12
    Views
    1,402

    I live in central New Jersey (Mounmouth county)....

    I live in central New Jersey (Mounmouth county). I'd appreciate a good recommendation. But why the installer is so important? I am only replacing the old system and it should be a EASY job, isn't it?
  15. Replies
    12
    Views
    1,402

    It is a 10 seer system.

    It is a 10 seer system.
  16. Replies
    12
    Views
    1,402

    I got a quote for a complete trane system: 3ton...

    I got a quote for a complete trane system: 3ton AC, 80% Furnice for $3216.
    Cooling: Trane XB 1000 TTB036C
    Heating: Trane TUE080A936K*

    10 year parts. 1 year labor.

    Fair deal?
  17. Replies
    12
    Views
    1,402

    What is a Magic Chef CJK anyway? I don't see the...

    What is a Magic Chef CJK anyway? I don't see the brand anywhere.

    I don't think I can breakeven for a 13 seer, instead of a 10 seer. My concern is that after 2006, the 10 seer could not be repaired...
  18. Replies
    12
    Views
    1,402

    Thank you, dhvac. Sould I chose a 10 seer for...

    Thank you, dhvac.

    Sould I chose a 10 seer for the next 18 years, or an

    much more expensive 13 seer?

    For 13 seer, the airhadler will have to be changed also.
  19. Replies
    12
    Views
    1,402

    Hi, My current ac is 18 years old Magic Chef...

    Hi,

    My current ac is 18 years old Magic Chef CJK (?). The outside fan just stopped working.

    Should I just get the fan changed? Or should I get the entire ac changed, since it is near its end of...