  1. Thread: Is this bad?

    by Mikey83
    Replies
    12
    Views
    2,010

    Look like an EngAir, have had that happen to me...

    Look like an EngAir, have had that happen to me once before.
  2. Replies
    27
    Views
    4,591

    I agree, but I assumed he checked all legs to...

    I agree, but I assumed he checked all legs to compressor, checked amp draw etc before recommended a replacement.

    Easier to see a blower motor single phasing on start up as it just shakes and...
  3. Replies
    27
    Views
    4,591

    Ive "un-stuck"(got going) a few 3 phase...

    Ive "un-stuck"(got going) a few 3 phase compressors by reversing any 2 legs of power going to it. Again this would work in a reciprocating application, and sometimes it works sometimes not. Even...
  4. Replies
    52
    Views
    9,202

    Service doors can be opened with no obstructions,...

    Service doors can be opened with no obstructions, Great work
  5. Replies
    7
    Views
    1,421

    Shouldn't the humidifier supply be connected down...

    Shouldn't the humidifier supply be connected down in the main plenum to ensure that all supply branches get equal amount of humidity throughout the house? Way it looks now is the branch coming out...
  6. Replies
    13
    Views
    2,390

    x2

    x2
  7. Replies
    1
    Views
    1,817

    Romantic Winter Vacation

    Two young lovers go up to the mountains for a romantic winter vacation. When they get there the guy goes out to chop some wood. When he gets back, he says,'Honey, my hands are freezing! She says,...
  8. Replies
    3
    Views
    3,946

    Whoa, old thread

    Whoa, old thread
  9. Replies
    23
    Views
    1,725

    x2

    x2
  10. Thread: twin boilers

    by Mikey83
    Replies
    14
    Views
    2,292

    x2

    x2
  11. Replies
    34
    Views
    2,369

    Need your refrig license as well as a G1 and...

    Need your refrig license as well as a G1 and you'll have a job no problems here.
  12. Replies
    34
    Views
    2,369

    haha i'm talking about me personally, rather work...

    haha i'm talking about me personally, rather work in the summer than the winter any time.
  13. Replies
    34
    Views
    2,369

    Personally I would take that year round than the...

    Personally I would take that year round than the frigid winters we deal with. Hey we have 4 seasons here with like I said hot summers and frigid winters so you know we are busy year round because of...
  14. Replies
    34
    Views
    2,369

    Of course you need your ticket and G1 to get...

    Of course you need your ticket and G1 to get looked at.
  15. Replies
    34
    Views
    2,369

    Come up here to Ontario, lots of work. Good union...

    Come up here to Ontario, lots of work. Good union pay but be ready to work in extreme humid summers and cold windy winters.
  16. Thread: Wifey Jokes

    by Mikey83
    Replies
    1
    Views
    1,109

    Wifey Jokes

    Wife: "What are you doing?"
    Husband : Nothing.
    Wife : "Nothing...? You've been reading our marriage
    certificate for an hour."
    Husband : "I was looking for the expiration date."



    I was...
  17. Replies
    204
    Views
    27,355

    What I bring on roof per call to troubleshoot...

    What I bring on roof per call to troubleshoot first.
    No Heat call - Fluke meter, 11 in 1 Klein, Jumpers
    No Cooling - 410A single gauge with straight connection (test both high and low side), Fluke...
  18. x2, if you have a ticket here in Ontario not hard...

    x2, if you have a ticket here in Ontario not hard to find work.
  19. Replies
    8
    Views
    694

    I agree, lil bit more time on install since have...

    I agree, lil bit more time on install since have to run an 2-wire for sensor.
    But you can always lock out the screen and have the stat display an offset of the actual temperature +/- 1.5C hah
  20. Replies
    11
    Views
    1,973

    I have seen that error than go away, chiller...

    I have seen that error than go away, chiller running fine from what I can tell other than that error. Should I be worried?
  21. Thread: She's a beaut!

    by Mikey83
    Replies
    16
    Views
    2,721

    The explains everything

    The explains everything
  22. Thread: RTU Changeouts

    by Mikey83
    Replies
    33
    Views
    3,951

    Here in Ontario no flex line allowed, as it would...

    Here in Ontario no flex line allowed, as it would be all black piped to the unit including a drip pocket before riser. On first picture you have the draft motor blasting the exhaust right on the gas...
  23. Replies
    19
    Views
    1,711

    hah thanks for the info, ya I only do ressy now...

    hah thanks for the info, ya I only do ressy now as side jobs on weekends. I work on rooftops/chillers/refrigeration/pneumatics/building automation/boilers/geo-thermo, work for a smaller company with...
  24. Replies
    19
    Views
    1,711

    I would of course get a job before I moved , but...

    I would of course get a job before I moved , but as I stated I was more into getting information on how it is working there before I went ahead. I'm making almost 38 an hour now and that is about...
  25. Replies
    19
    Views
    1,711

    Im in a non-union company now anyways My...

    Im in a non-union company now anyways

    My original post was more to find out how it is working in Florida, how are the hourly rates and how is the job market. But every question answered seems that...
Results 1 to 25 of 28