  1. Replies
    13
    Views
    4,009

    What specific manual are you looking for? They...

    What specific manual are you looking for? They are listed per software version and each individual piece of hardware. For instance WebCtrl 4.1, WebCtrl 5.2, WebCtrl 5.5, InterOp, Supervision, ect.
  2. Replies
    11
    Views
    1,563

    You need to know your layout first. It could be...

    You need to know your layout first. It could be something as simple as a LAN module offline and the other LAN module works, therefore you see part of the school. It could be a comm problem, if you...
  3. Replies
    52
    Views
    5,411

    SOME UNIs are obsolete, Uni 16 and 32 are still...

    SOME UNIs are obsolete, Uni 16 and 32 are still somewhat around, LGEs are still available too, UNI 59s and 30s are long gone. All of these controllers that you mention are still supported as far as...
  4. Replies
    18
    Views
    2,585

    WC5.5 does not support it but as stated above,...

    WC5.5 does not support it but as stated above, now in Beta. Safari amoung others will be supported
  5. Thread: Low cap wire.

    by hotrod53
    Replies
    2
    Views
    840

    Contact ALPS Controls.com and look up or ask for...

    Contact ALPS Controls.com and look up or ask for part number ARC156. That is the low cap wire that we use for ALC 156K baud networking. They have it available from 2 different vendors.
  6. I installed (2) grilles about 8 x 14 end to end...

    I installed (2) grilles about 8 x 14 end to end in my bulkhead, that opens into the cold air return plenum, above that I have a heavy duty 8 x 12" grille. If you look up in the registers above the...
  7. Trying to get heat from woodstove to rise in my split entry

    I have a nice sized wood burning stove in my gameroom, unfortunately if I get a good fire going it is too hot downstairs and I can't get enough to rise. So far I cut a hole in the floor directly...
  8. Replies
    12
    Views
    1,664

    Glad it worked out! Us old control guys know old...

    Glad it worked out! Us old control guys know old equipment .. LOL!
  9. Replies
    12
    Views
    1,664

    So thet tells me that you are not communicating...

    So thet tells me that you are not communicating from the Central Site to the LGE, it has nothing to do with your ArcNet.

    In control panel, is your port speed set above the stock connection speed...
  10. Replies
    12
    Views
    1,664

    Try this while setup on the port that you think...

    Try this while setup on the port that you think is the correct one to go into Control Panel and see what port you should be using.

    In Supervision, go to view and make sure that Manual Commands is...
  11. Replies
    12
    Views
    1,664

    The cable that you have is called a DC99 cable,...

    The cable that you have is called a DC99 cable, this is a direct connect cable that talks right to the LGE.

    PM or EMail me.
  12. Replies
    12
    Views
    1,664

    All of your errors are just an indication of no...

    All of your errors are just an indication of no connection. I need to know if you are connected via Direct connect or Ethernet. Do you have an CAT5 wire or an older DC99 15 pin cable connected to the...
  13. Replies
    11
    Views
    2,328

    I always prefer modulating... floating tends to...

    I always prefer modulating... floating tends to get lost and needs to be occasionally reset. Modulating is always a % based on control signal, but think of this... If a floating motor is advertised...
  14. Replies
    11
    Views
    3,346

    Like they said, no database, you're screwed. Most...

    Like they said, no database, you're screwed. Most reputable contractors would have left you the ALC install disks and a database, after all, you own both. You're going to have to look around for a...
  15. Replies
    3
    Views
    808

    WC 5.2 is currently only out in Beta but prices...

    WC 5.2 is currently only out in Beta but prices are being given, I have seen it once so far, it should hit the street any day now. WC 3.0 is still a usable option, not my favorite, but it works and...
  16. Replies
    10
    Views
    1,057

    As previously stated, depends on what area is...

    As previously stated, depends on what area is already covered. Here in PA there are only 2 and there is no overlap. You can go on the ALC Website www.automatedlogic.com and "find a dealer", that...
  17. Replies
    10
    Views
    2,220

    Like I tell my customers who think that BacNet is...

    Like I tell my customers who think that BacNet is a do-all integration, the first time that you have to replace a module and download memory, or you need to change a program, you're screwed. These...
  18. Do you have a large network or maybe an old...

    Do you have a large network or maybe an old legacy network not talking at 156K? Maybe it just didn't make the loop as quickly as expected, or maybe you have a noisy network? It really should have...
  19. Is your computer showing the correct time? Have...

    Is your computer showing the correct time? Have you done a time sync? Go to CFG, system settings, scheduled tasks, and click RUN NOW at the bottom of the list. This is of course AFTER you confirm...
  20. Replies
    34
    Views
    6,343

    So it sounds like you disconnected the plug on...

    So it sounds like you disconnected the plug on the circuit board marked IGM and plugged in the plug marked Intellislot. Did you plug into the Intellislot using the supplied blue cable and set up the...
  21. Replies
    15
    Views
    2,940

    It sounds like you guys may know something that I...

    It sounds like you guys may know something that I haven't heard yet. I have seen WC5.2 Beta and I spend a whole 2 minutes on it to update a licence for a customer. We actually had a seminar on it and...
  22. Replies
    15
    Views
    2,940

    You can "suck the program" out even when using...

    You can "suck the program" out even when using WC4.1, but you do it while connected to the module using your laptop as a server.

    How about this, connect wirelessly with your laptop or even "suck...
  23. Replies
    9
    Views
    676

    I'm a big fan of the Controlair 500DC 3/15#...

    I'm a big fan of the Controlair 500DC 3/15# units, but they are 1-9V. I'm sure they have a 4-20 unit too. Careful setting them up, the adjustable pots are REALLY tiny and require a super small...
  24. Replies
    34
    Views
    6,343

    Oh, I missed that. Yes, I integrate thru a...

    Oh, I missed that. Yes, I integrate thru a Sitelink which sounds different than what you are using.
  25. Replies
    10
    Views
    1,992

    I just had the same problem between ALC and...

    I just had the same problem between ALC and Liebert PDUs. We were using a beta driver, it worked for a while and quit. Modscan showed good data but on the ALC side every modbus point, and I'll use...