  1. Replies
    16
    Views
    770

    Ive pointed out things to the customer, but...

    Ive pointed out things to the customer, but NEVER, NEVER said the company or persons name. It just annoys me because people get away with it. I dont see how theyre still in business. And it seems...
  2. Replies
    16
    Views
    770

    well the customer said he had a green jug of...

    well the customer said he had a green jug of something and said he put in a couple pounds. How many green 410a jugs have you seen?
  3. Replies
    16
    Views
    770

    Moral Advice?????

    The past few months customers have been telling how bad of service other companies have been giving them. Mostly guys pretending to be HVAC Techs or basically jack legs. Some customers are even...
  4. Replies
    63
    Views
    5,098

    And ive tried calling for fall maintenance...

    And ive tried calling for fall maintenance specials. A couple did, but thats about all. Money is tight with everyone, and you can't make the customer understand that it will help them save in the...
  5. Replies
    63
    Views
    5,098

    Just hope and pray that it gets cold soon. Ive...

    Just hope and pray that it gets cold soon. Ive already applied at several HVAC companies.
  6. Replies
    28
    Views
    4,648

    Propane combusts and leaves behind CO and H20.

    Propane combusts and leaves behind CO and H20.
  7. Replies
    63
    Views
    5,098

    Business slow for everyone?

    Is it just me? My business has came to a dead stop for the past couple weeks. a few estimates, a service call here and there but never seen it this bad. This summer was great, but these mild days,...
  8. Replies
    11
    Views
    915

    3 ton, they called in an electrician to rewire...

    3 ton, they called in an electrician to rewire and put in new disconnects, which is fine cause they have no room for wire or any room on their box, and id rather not mess with all that if i can help...
  9. Replies
    14
    Views
    1,365

    I sprayed water on it..........LOL. I actually...

    I sprayed water on it..........LOL. I actually eyeballed it according to the color of the flame and then WC and was pretty damn close.
  10. Replies
    14
    Views
    1,365

    I stuck with it until i was 100% sure what the...

    I stuck with it until i was 100% sure what the problem was and then i fixed it. Sometimes for me it takes a little longer to diagnose some things being that i am small one man business and i dont...
  11. Replies
    14
    Views
    1,365

    And i never said i was bypassing it, i meant i...

    And i never said i was bypassing it, i meant i didnt want anyone telling me to bypass it. I also adjusted the gas was burning too hot.
  12. Replies
    14
    Views
    1,365

    ended up being completely stopped up, soot, kinda...

    ended up being completely stopped up, soot, kinda like black mud. Also had a crack in the middle. Was under warranty and changed it out today. Runs like new. 13 year old gmpn100-4 goodman gas furnace.
  13. Replies
    14
    Views
    1,365

    Rollout switch

    What else would keep making the rollout open? Checked exchanger, checked gas pressure. Runs fine until i leave. Keep coming back to find the same one open. Any suggestions, besides bypassing it?
  14. Replies
    11
    Views
    915

    It just disgusts me that people are willing to...

    It just disgusts me that people are willing to put homes, families, and lives at risk to make an extra buck. What goes around comes around. So many people in my area, Upstate SC, are pretending to be...
  15. Replies
    11
    Views
    915

    Found a Fire waiting to happen.

    Found a 10kw heat strip and blower fan wired with 6-2 wire through a 45 amp breaker. Went to pull the disconnect first and it was too hot to even grab. This led me to finding the heat strips and the...
  16. Replies
    112
    Views
    10,617

    Well, an experienced tech can go on gut instinct...

    Well, an experienced tech can go on gut instinct because ive see it time and time again. Usually can tell right off if its just surface rust or rusted all the way through. Just get a Trane with a...
  17. Replies
    19
    Views
    1,569

    Bad inspectors are usually the ones that got...

    Bad inspectors are usually the ones that got bullied in high school. They got the power to bully and they will use it. There is still a few good ones here and there.
  18. Replies
    112
    Views
    10,617

    Id look at it if it were my own. The risk of...

    Id look at it if it were my own. The risk of running it would be too dangerous and i would tell the customer that. Its all about safety and my family comes first. I always go with my gut feeling....
  19. Replies
    19
    Views
    2,788

    when all else fails, you can always dump the load...

    when all else fails, you can always dump the load and weigh it back in. Never fails!
  20. They also wanted to leave out the heat strips...

    They also wanted to leave out the heat strips because they have wood heat for backup. I didnt recommend it but they were the ones paying, not me.
  21. Im not a DIYer and i was installing this for a...

    Im not a DIYer and i was installing this for a friend/neighbor. They bought tstat and all materials. I was trying to help them out and save them money.They also installed the tstat which in most...
  22. Replies
    10
    Views
    739

    Nothing yet

    Ive never left the heat strips out before and im just paranoid. Should it run in aux for a while before the compressor kicks in? I have double checked and triple checked all wiring. It is...
  23. Heat strips

    I rechecked all my wiring, everything is wired but common and brown going to heat strips. AC works fine, compressor and everything comes on. When switched to heat, the blower fan comes on, no...
  24. Replies
    10
    Views
    739

    what should i check for? Ive never had this...

    what should i check for? Ive never had this happen.
  25. Replies
    10
    Views
    739

    Brand new unit

    This is a brand new unit, just installed it. everything is hooked up, tstat wiring is correct. AC comes on and operates like it is intended. only thing not wired is Common, and brown going to where...