    The good news is that these issues have brought...

    The good news is that these issues have brought us to ask more questions to Honeywell about EBI. Just another question for you guys...as a long term solution (10-15 years) which software looks to be...
  2. Replies
    20
    Views
    4,783

    The only problem is the age of what we have right...

    The only problem is the age of what we have right now, our current VAV controllers are R7457A1000 as here: http://europe.hbc.honeywell.com/historic_products/2003_1/docs/R7457.html

    I do not believe...
  3. Replies
    20
    Views
    4,783

    Thanks guys, I assume the WEBs controllers are...

    Thanks guys, I assume the WEBs controllers are then compatible with EBI as well? These are the tridium JACEs correct? Something like the WEB-403 which is non-AX specific is what I was thinking of.
    ...
  4. Replies
    20
    Views
    4,783

    Even though they are LON devices, it looks like...

    Even though they are LON devices, it looks like they use LON to communicate only with other controllers. The zone manager looks like it converts this LON to C-Bus. Is there another device to send it...
  5. Replies
    20
    Views
    4,783

    Honeywell VAV Control

    Hi everyone,

    We are looking at a possible staged upgrade path for our Dual VAV controllers. Our current installation is an old (approx 10 years) Honeywell C-Bus system, and the reason for upgrade...
  6. Replies
    3
    Views
    1,103

    Another update!...

    Another update! http://www.abb.com/product/us/9AAC113388.aspx

    DriveWindow Light looks like it just does the parameters and a couple other things. Hopefully I can work with my rep to get it for...
  7. Replies
    3
    Views
    1,103

    Figures that right after I post I find something....

    Figures that right after I post I find something. ABB's DriveStudio. Not a whole lot of info out there, but I had somewhat assumed that a utility like this should have been free, though I don't think...
  8. Replies
    3
    Views
    1,103

    ABB/Siemens VSD Parameters

    I've tried to search around, but small search terms can't be done. So hopefully someone can help me find a utility to upload/download vsd parameters for these two companies from a laptop.

    So far...
  9. Thread: EBI Upgrade

    by Droshi
    Replies
    19
    Views
    1,245

    Yeah, we have known that there is an import tool...

    Yeah, we have known that there is an import tool from XBS (our current software) to EBI. The problem is that as you say it will be sort of a temporary solution, that will work and would be the...
  10. Thread: EBI Upgrade

    by Droshi
    Replies
    19
    Views
    1,245

    Would we have to purchase different points to be...

    Would we have to purchase different points to be used on the LONworks server? Or they don't operate on a point basis?
  11. Thread: EBI Upgrade

    by Droshi
    Replies
    19
    Views
    1,245

    One other question I have is: Can these points be...

    One other question I have is: Can these points be only used for the Excel 5000 point server? Or can they be used in conjunction with a LON point server?

    Right now we only have XL500 controllers,...
  12. Thread: EBI Upgrade

    by Droshi
    Replies
    19
    Views
    1,245

    Thanks very much for the help. Our next...

    Thanks very much for the help.

    Our next problem is just training! Once we really figure out the capabilities of EBI we can start planning better on redoing all of our graphics. Any suggestions?
  13. Thread: EBI Upgrade

    by Droshi
    Replies
    19
    Views
    1,245

    You seem to be saying that only points being...

    You seem to be saying that only points being displayed will be counted by the software is that correct?

    A typical VAV page for us has about 17 points being displayed (dampers, flow rates, flow...
  14. Replies
    2
    Views
    427

    More on the type of system would be nice. Is this...

    More on the type of system would be nice. Is this an air handler that supplies a single room? Single/Dual Duct with return? Is it a fan coil with a seperate heating unit? If you have a duct...
  15. Thread: EBI Upgrade

    by Droshi
    Replies
    19
    Views
    1,245

    EBI Upgrade

    This is a bit of a strange question, but does anyone know how to calculate how EBI uses points for licensing purposes? We would be using an Excel 5000 direct point server and modbus interface for...
  16. Replies
    22
    Views
    958

    Yeah, 12 psi will be plenty for me. I was...

    Yeah, 12 psi will be plenty for me. I was confused by conversion as I don't think in psi really.

    I've rigged up a good magnahelic setup now, so I'm pretty happy with it. I just need to get a...
  17. Replies
    0
    Views
    1,125

    Vaisala HMC 20 Datasheet

    Hi all,

    Wondering if anyone happens to have the datasheet for this device. We have the HMC 20 and HMP 20B probe. I can't find anything all that relevant on a google search and nothing on this...
  18. Replies
    7
    Views
    1,436

    I would make sure to highlight possibilities to...

    I would make sure to highlight possibilities to management, and really determine what they want. A month from now if they decide a strobe light isn't effective enough, you'll be changing it out for...
  19. Replies
    7
    Views
    760

    Honeywell Gray Manual has a wealth of information...

    Honeywell Gray Manual has a wealth of information related to controls, and can be found via Google as a free download. It's called Honeywell Engineering Manual of Automatic Control, or something like...
  20. Replies
    22
    Views
    958

    In my opinion, it's not really necessary. It...

    In my opinion, it's not really necessary. It saves a bit on fan speed, but really how much actual electrical savings is that? Especially for all that programming. I would say it's a much better idea...
  21. Replies
    22
    Views
    958

    Easy enough, we usually work with voltage signals...

    Easy enough, we usually work with voltage signals (Honeywell products), but also I usually have someone in the office that can view it from the software as well.

    To generate the higher pressures...
  22. Replies
    22
    Views
    958

    Good points. I don't need something extremely...

    Good points.

    I don't need something extremely accurate, as you've said, most times close enough is good enough. But I would like something quick and easy to check the pressure transducers against...
  23. Replies
    22
    Views
    958

    I'm doing building management for a number of...

    I'm doing building management for a number of buildings. Most of the HVAC is standard office, but we have a couple special rooms as well as other special applications that are on our DDC system.
    ...
  24. Replies
    22
    Views
    958

    Beer: That sounds like a nice idea, how far can...

    Beer:
    That sounds like a nice idea, how far can you run the poly line? In some places our panels are a bit of a distance from the pressure sensors, but for future it's nice to keep in mind.

    Also,...
  25. Replies
    22
    Views
    958

    Field Pressure Transducer Calibration Setup

    Hi all,

    I'm wondering what sort of setup is ideal for this sort of field calibration? The pressure transducers are for static duct pressure: http://www.mamacsys.com/PR-276features.htm

    We...