Search:

Type: Posts; User: Bkrieg86

Search: Search took 0.00 seconds.

  1. Thread: Vacuum pumps

    by Bkrieg86
    Replies
    12
    Views
    492

    Thank you I do residential and some light...

    Thank you I do residential and some light commercial and ended up with 2 stage CPS 8 cfm pump. I couldn't beat the price at the time and my boss pushed me towards it a little. And I have a couple...
  2. Thread: Vacuum pumps

    by Bkrieg86
    Replies
    12
    Views
    492

    Well I ended up with the CPS my boss kinda took...

    Well I ended up with the CPS my boss kinda took control of that one. But I did get an appion g5 recovery machine.
  3. Thread: Vacuum pumps

    by Bkrieg86
    Replies
    12
    Views
    492

    Vacuum pumps

    So I am going to purchase a vacuum pump. I can get a CPS brand 8 cfm for 320 or a Robin aire 6 cfm for 370 opinions?
  4. Replies
    31
    Views
    1,038

    Thank you for all the info. We finally got it...

    Thank you for all the info. We finally got it working today. New propane tank new regulators and new manifold orifices and an extremely thorough cleaning and finally no issues. Now I have a happy...
  5. Replies
    31
    Views
    1,038

    And burners are new

    And burners are new
  6. Replies
    31
    Views
    1,038

    Not without moving the boiler itself

    Not without moving the boiler itself
  7. Replies
    31
    Views
    1,038

    The tech on site just replaced pilot and said...

    The tech on site just replaced pilot and said that the flame in the tubes is not on any particular tube it happens to a single or set of random tubes and it's different every time. I'm at a complete...
  8. Replies
    31
    Views
    1,038

    Lol okay you're right I have nothing to lose

    Lol okay you're right I have nothing to lose
  9. Replies
    31
    Views
    1,038

    Pilot is intermittent spark. How could leaky...

    Pilot is intermittent spark. How could leaky pilot cause flame inside burner tubes
  10. Replies
    31
    Views
    1,038

    Propane company was out and said no moisture in...

    Propane company was out and said no moisture in lines I forgot to mention that sorry
  11. Replies
    31
    Views
    1,038

    Bryant boiler issue

    So I'm on a Bryant 210k btu propane water boiler. We keep getting fire in the burner tubes. Manifold pressure is at 10 per data plate. The flue and chimney and water jackets have been cleaned. When...
  12. Replies
    31
    Views
    1,038

    Thanks. I missed the tech to tech forum I will...

    Thanks. I missed the tech to tech forum I will repost issue there.
  13. Replies
    31
    Views
    1,038

    28 Co 5.4o2 5.6co2

    28 Co 5.4o2 5.6co2
  14. Replies
    31
    Views
    1,038

    We used a uei c 155 and also a water column gauge...

    We used a uei c 155 and also a water column gauge to check draft and correct combustion and pressures
  15. Replies
    31
    Views
    1,038

    And air shutters have been adjusted correctly by...

    And air shutters have been adjusted correctly by our most senior tech.
  16. Replies
    31
    Views
    1,038

    Burners were replaced last week

    Burners were replaced last week
  17. Replies
    31
    Views
    1,038

    We know that but it's the only way we could keep...

    We know that but it's the only way we could keep it running for a short time to heat customer. We aren't leaving until it's figured out
  18. Replies
    31
    Views
    1,038

    Bryant boiler issues

    Can't figure this one out. On a 96 Bryant 210k btu propane boiler. We have changed the gas valve cleaned the water jackets and the flue and swept the chimney. We have confirmed draft and combustion...
  19. Replies
    0
    Views
    182

    Beckett video training library

    Does anybody remember the fake hvac company in these videos I can't find my old vhs tapes and can't find anyone who knows

    Sent from my SCH-I545 using Tapatalk
  20. Thread: New to Site

    by Bkrieg86
    Replies
    2
    Views
    309

    That helps quite a bit. And Starting at the top...

    That helps quite a bit. And Starting at the top leaves a longer way to fall. So working my way up is more self rewarding in my eyes. Plus it helps me show my kids that with patients comes great...
  21. Thread: New to Site

    by Bkrieg86
    Replies
    2
    Views
    309

    New to Site

    Hello all my name is Ben Krieg. I have yet to begin a career in Hvac but would absolutely love to, I plan to start school this year but would love some recommendations from the "experts" as to the...
Results 1 to 21 of 21