10-14-2012, 11:24 PM
Thread: Need help on hill pheonix rack system
by gerryboy00- Replies
- 18
- Views
- 1,915
i guess that the compressor (that fills up) is...
i guess that the compressor (that fills up) is not running and that the oil is comming back from the suction line header is that possible?
-
09-13-2009, 11:11 PM
Thread: ***Hvac2009 Football Pool***
by gerryboy00- Replies
- 298
- Views
- 9,663
1
1
-
06-28-2009, 12:10 AM
Thread: Turbocor Help:Ask Questions
by gerryboy00- Replies
- 58
- Views
- 7,180
I am very impress, very good compressor, so far,...
I am very impress, very good compressor, so far, as I know, one IGV was replaced on a 90 ton compressor......the bad side of the compressor is the procedure for oil replacement....
-
11-21-2008, 05:15 PM
Thread: How to diagnose LLSV?
by gerryboy00- Replies
- 8
- Views
- 601
disconect the LLS and keep the suction pressure...
disconect the LLS and keep the suction pressure low by starting the compressor manually....check for frost after the valve
-
10-24-2008, 11:06 PM
- Replies
- 8
- Views
- 531
hahaha:D and i know exactly where...;)
hahaha:D and i know exactly where...;)
-
10-24-2008, 12:48 PM
- Replies
- 8
- Views
- 531
Y894 Receiver Pressurization Valve Description...
Y894 Receiver Pressurization Valve
Description
The Y894 is a differential pressure regulating valve used on surge
receiver type systems. It is installed in a line from the discharge of
the system... -
10-14-2008, 10:30 PM
Thread: Rack Oil System
by gerryboy00- Replies
- 22
- Views
- 1,161
huh??
huh??
-
10-09-2008, 11:31 PM
Thread: Rack Oil System
by gerryboy00- Replies
- 22
- Views
- 1,161
open
open
-
08-12-2008, 12:00 AM
Thread: head master
by gerryboy00- Replies
- 16
- Views
- 1,349
??? think? why?
??? think? why?
-
08-11-2008, 11:52 PM
Thread: Walk In - High Head - Low Suction
by gerryboy00- Replies
- 25
- Views
- 1,363
what changed in this system ?? the room...
what changed in this system ?? the room temperature very high load
you need to install a cpr on the suction line not to overload the unit.....im surprise that the compr. doenst trip on overload!! -
07-10-2008, 09:20 PM
- Replies
- 8
- Views
- 1,114
can u explain ?
can u explain ?
-
07-10-2008, 09:15 PM
Thread: hussman rack
by gerryboy00- Replies
- 5
- Views
- 1,770
be sure you have a minimum of 20 psig Oil...
be sure you have a minimum of 20 psig Oil differential check valve on the oil receiver,
check oils trainers, filters etc -
07-07-2008, 11:09 PM
Thread: Bitzer Compressor in Wind tunnel
by gerryboy00- Replies
- 9
- Views
- 944
i prefer copeland too
i prefer copeland too
-
07-07-2008, 10:59 PM
Thread: Water Reg Valve on older Liebert
by gerryboy00- Replies
- 3
- Views
- 586
http://www.acmeref.biz/Kpublic/Documents%5Cpen_v46...
http://www.acmeref.biz/Kpublic/Documents%5Cpen_v46_water_valve.pdf
-
07-07-2008, 10:45 PM
Thread: rack oil separator isolation porcedure
by gerryboy00- Replies
- 19
- Views
- 1,161
NO
NO
-
07-07-2008, 10:37 PM
Thread: Bitzer Compressor in Wind tunnel
by gerryboy00- Replies
- 9
- Views
- 944
the water-cooled cylinder heads are an option ....
the water-cooled cylinder heads are an option . now, do the old heads will fit in dunno
http://www.thermagroup.com/bitzer2.php -
06-26-2008, 10:41 PM
Thread: Bitzer Compressor in Wind tunnel
by gerryboy00- Replies
- 9
- Views
- 944
the replacement is a 4V6.2 ...
the replacement is a 4V6.2
http://www.bitzer.de/en/products/index.php?PKEY=K-HH1-V&PTYP=4V-6.2 -
04-12-2008, 04:40 PM
Thread: Sabroe compressor help
by gerryboy00- Replies
- 1
- Views
- 476
how about 4 hrs per head 6 X 4hrs= 24 hrs (12...
how about 4 hrs per head
6 X 4hrs= 24 hrs (12 pistons)
8 X 4hrs= 32 hrs (16 pistons) -
04-12-2008, 04:29 PM
Thread: Walk-in cooler\freezer on 404?
by gerryboy00- Replies
- 8
- Views
- 1,003
leave the epr on the med.temp circuit adjust it...
leave the epr on the med.temp circuit adjust it at about 55 psig then adjust the desire set point on the thermostat.
adjust lpc cut in at 20 psig cut out at 5 psig -
03-24-2008, 02:18 PM
- Replies
- 74
- Views
- 3,869
april 13 8:25 am 8 lbs 4 oz
april 13
8:25 am
8 lbs 4 oz -
03-08-2008, 09:44 AM
Thread: Walkin Cooler with funny pressures
by gerryboy00- Replies
- 17
- Views
- 1,144
give us some number SuPeRhEaT and sUpErHeAt ...
give us some number
SuPeRhEaT and sUpErHeAt :) -
01-27-2008, 09:51 PM
- Replies
- 22
- Views
- 2,535
make sure it is the good valve, and replace it. ...
make sure it is the good valve, and replace it.
adjustable valve ? -
01-18-2008, 07:31 PM
Thread: Need IOM for York RTU
by gerryboy00- Replies
- 6
- Views
- 562
http://www.yorkupg.com/NewInfo.asp?id=53&t=c&PID=7...
http://www.yorkupg.com/NewInfo.asp?id=53&t=c&PID=7#Pubs
under tech guide -
01-17-2008, 10:48 PM
Thread: Torch setup
by gerryboy00- Replies
- 28
- Views
- 2,213
one thing i always used is............
one thing i always used is............
-
01-17-2008, 10:39 PM
- Replies
- 9
- Views
- 2,135
copy from my manual
This is the time delay after which the control will attempt to restart the XDC after a loss of power. It
is programmable from 0.1 to 9.9 minutes in 6-second (0.1 minute) increments. The user can...
Results 1 to 25 of 500