Search:

Type: Posts; User: T87F

Page 1 of 4 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    22
    Views
    3,152

    Try this..................

    Try this...............
    http://www.vetopropac.com/catalog/laptop-series
  2. Replies
    10
    Views
    741

    Thanks my friend

    Thanks my friend
  3. Replies
    10
    Views
    741

    My profile has an email address. Thanks

    My profile has an email address.
    Thanks
  4. Replies
    10
    Views
    741

    That would be great

    That would help a lot, I could not find that info.
  5. Replies
    10
    Views
    741

    Thanks for the info, I will try that.

    Thanks for the info, I will try that.
  6. Replies
    10
    Views
    741

    Add VMA controller points to an FX40

    I have a job that has an FX40 with VMA controlers on the N2 bus. I have FX Workbench 5.1 to access the FX40. The controlers have been discovered but there are no points for these VMA controlers. How...
  7. E-Vision will NOT work with any kind of USB...

    E-Vision will NOT work with any kind of USB device (as far as I know). With PC's without a PCMCIA slot you need to use the old SLTA box.
  8. Replies
    22
    Views
    3,152

    A veto backpack...........................

    A veto backpack........................
    http://www.vetopropac.com/products/tech-pac
  9. No, it will not work...................

    No, it will not work...................
  10. Replies
    65
    Views
    9,929

    EBI when installed correctly works great. Most...

    EBI when installed correctly works great. Most complaints come from poor installations by untrained people. It's a powerful tool when setup correctly.
  11. Replies
    35
    Views
    2,933

    Having worked both service and construction I...

    Having worked both service and construction I prefer the service end. When arriving on a service call the customer is usually glad to see you. Construction is dog eat dog for the most part....
  12. Replies
    1
    Views
    694

    Yes, you can run Station R410 on an XP Pro 32 bit...

    Yes, you can run Station R410 on an XP Pro 32 bit PC. Make sure you read and follow the upgrade procedure, it should go fine.
  13. Replies
    204
    Views
    33,297

    Fenix TK11

    Fenix TK11
  14. Thread: Honeywell Valves

    by T87F
    Replies
    2
    Views
    736

    https://customer.honeywell.com/en-US/Pages/default...

    https://customer.honeywell.com/en-US/Pages/default.aspx
  15. Thread: Tridium shakeup

    by T87F
    Replies
    8
    Views
    1,236

    Tridium is slowly being assimilated into mother...

    Tridium is slowly being assimilated into mother Honeywell, resistance is futile. Thinning out middle management is the first step.
  16. Thread: Honeywell EBI

    by T87F
    Replies
    7
    Views
    1,764

    Quick builder will not be much help with the...

    Quick builder will not be much help with the XL-Plus points. Only a point list (generated from the CAE database) or access to the CAE project will tell you how the panel is wired.
  17. Thread: Honeywell EBI

    by T87F
    Replies
    7
    Views
    1,764

    Only for the XL5000 controlers will this work,...

    Only for the XL5000 controlers will this work, plus you will need the CARE project. For the XL-Plus points you will either a point list or the CAE Rebuild file or the CAE project itself.
  18. Thread: Honeywell EBI

    by T87F
    Replies
    7
    Views
    1,764

    Technical address of 06.01.01 means...

    Technical address of 06.01.01 means channel.controller.point. Any point with XLP in front of the address is a point from a R7044 XL-Plus type controller. XLP01 001 19000060DO means Buss 1, channel 1,...
  19. Thread: Honeywell XC5010

    by T87F
    Replies
    5
    Views
    1,536

    XD505A cards

    I change a lot of XD505A cards, most of the time due to lightning strikes. It is always the first thing I look at.
  20. Replies
    7
    Views
    1,275

    What controlers are you working on?

    What controlers are you working on?
  21. Replies
    24
    Views
    3,185

    At $0.50/KM = $0.80/mile, 1.61 kilometer = 1...

    At $0.50/KM = $0.80/mile, 1.61 kilometer = 1 mile. If you drive 300 miles per week that adds up to $241.5. That would be close to $1000/month, or say $12,000 per year. This should support the vehicle...
  22. Replies
    7
    Views
    1,275

    Need more info

    More info needed..............
    Controler number?
    Software being used to commision?
  23. Agree, a power failure should not break the LON...

    Agree, a power failure should not break the LON links with the LNS database.
  24. Thread: Wifi thermostat

    by T87F
    Replies
    6
    Views
    1,228

    http://www.cypressenvirosystems.com/products/wirel...

    http://www.cypressenvirosystems.com/products/wireless-pneumatic-thermostat/
  25. Thread: Wifi thermostat

    by T87F
    Replies
    6
    Views
    1,228

    Just did some WiFi pneumatic stats talking to a...

    Just did some WiFi pneumatic stats talking to a bacnet interface, works real nice.
  26. Replies
    11
    Views
    1,698

    Resistance is futile

    Resistance is futile
  27. Replies
    11
    Views
    1,698

    GE tried to buy us (Honeywell) a while back but...

    GE tried to buy us (Honeywell) a while back but the deal was crushed by the European Market. Glad it never happened, GE stock is in the 20''s while Honeywell stock is in the 50's. GE would have...
  28. Replies
    5
    Views
    1,151

    Look on the inside of the cover............

    Look on the inside of the cover............
  29. Thread: hvac veto bag

    by T87F
    Replies
    175
    Views
    31,916

    It would help going up ladders for sure, I would...

    It would help going up ladders for sure, I would like it for general day to day use. Grabbing the tool bag (LC) from the truck and walking to the job, after 10 minutes or so I find myself having to...
  30. Thread: hvac veto bag

    by T87F
    Replies
    175
    Views
    31,916

    Finally!!!!!!!!!!!!!!!!! Coming...

    Finally!!!!!!!!!!!!!!!!! Coming soon......................

    http://www.slipkid.com/MyPictures/Misc/Misc-Pictures/i-Xdc2h9K/0/X3/185-X3.jpg
  31. Thread: JCI N2 Pathways

    by T87F
    Replies
    21
    Views
    1,918

    The S4 Open works great, simplest bacnet job I...

    The S4 Open works great, simplest bacnet job I have ever done.
  32. Thread: hvac veto bag

    by T87F
    Replies
    175
    Views
    31,916

    It's still a pain to walk up ladders with the LC...

    It's still a pain to walk up ladders with the LC bag. I wish they had a backpack version. It's still a great bag,,,,,,,,,,,,,,
  33. Replies
    4
    Views
    420

    I got the original controler back up and running....

    I got the original controler back up and running. After 4 or 5 tries (power on/off the controller) it would communicate with HVAC-Pro. I was unable to get the new controler to communicate, not sure...
  34. Replies
    4
    Views
    420

    I have been having some control issues with this...

    I have been having some control issues with this controler and was tole to replace it. I ordered a new AS-AHU102 controler board. I set the N2 address to match the old controler and set all the...
  35. Replies
    4
    Views
    420

    JCI AHU102-0 controler comm problem, HELP!

    I am trying to replace the AS-AHU102 controler board. I have the address set for #79 but I can't communicate to the controler from HVAC-PRO. I put the old controler back in but I can't communicate...
  36. Replies
    10
    Views
    3,514

    How about a VMware virtual XP player and run HVAC...

    How about a VMware virtual XP player and run HVAC pro from there.
  37. Replies
    5
    Views
    551

    Not true................I have a customer with...

    Not true................I have a customer with 9000 points and 43 AHU's with ton's of trend reports. The only problem could be is if the points are set up for "fast" history. You don't want say 500...
  38. Replies
    13
    Views
    920

    The fan status point is on as is the occupied...

    The fan status point is on as is the occupied point. This one has me stumped, not a complex program.
  39. Replies
    13
    Views
    920

    I had a JCI Tech at my customer site to have a...

    I had a JCI Tech at my customer site to have a look at the problem. He could not figure out why some of the control loops would not work, he was stumped. He said maybe it's a hardware issue with the...
  40. Replies
    7
    Views
    688

    Make sure the "history" for this point is enabled...

    Make sure the "history" for this point is enabled in "Quick Builder" and then downloaded to "Station".
  41. Replies
    13
    Views
    920

    This unit has been working for years, problem...

    This unit has been working for years, problem started a few months ago. I am trying to find you email address on this system to send you the program files.
  42. Replies
    13
    Views
    920

    The fan's do turn on from the time schedule in...

    The fan's do turn on from the time schedule in the FX40. The occupied status point is "TRUE".
  43. Replies
    13
    Views
    920

    Fan status is "ON", the actuators will work if I...

    Fan status is "ON", the actuators will work if I override the point. I tried removing the FX40 from the system, same problem.
  44. Replies
    13
    Views
    920

    JCI AHU102-0 controler problem

    I have the following :
    JCI AHU102-0 controler
    JCI HVAC Pro software
    FX40 interface
    The issue is that none of the control loops appear to be working. I have a mixing damper, face/bypass damper and...
  45. I use E-Vision from XP with the PCC-10 card. I...

    I use E-Vision from XP with the PCC-10 card. I had to use an old driver for the card. slta10_Win95_98_NT_2K_Ver1.04.002_A.exe
  46. Thread: hvac veto bag

    by T87F
    Replies
    175
    Views
    31,916

    The XL for me is too big to carry around on the...

    The XL for me is too big to carry around on the job. My LC get a bit heavy after a while but still works for me. The LC holds all that I need, I would like the LC-Tech but can not justify the cost...
  47. Thread: hvac veto bag

    by T87F
    Replies
    175
    Views
    31,916

    I would trade my current LC for the new LC-Tech...

    I would trade my current LC for the new LC-Tech bag. I like the one side with the larger pockets for meters and test equipment.
  48. Thread: hvac veto bag

    by T87F
    Replies
    175
    Views
    31,916

    I agree there, a half sized LC bag would be great.

    I agree there, a half sized LC bag would be great.
  49. Replies
    18
    Views
    3,565

    Maybe try a USB to PCMIA adapter. ...

    Maybe try a USB to PCMIA adapter.

    http://www.elandigitalsystems.com/adapter/u111530.php
  50. Thread: hvac veto bag

    by T87F
    Replies
    175
    Views
    31,916

    New Bags

    ?
Results 1 to 50 of 166
Page 1 of 4 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event