  1. Replies
    5
    Views
    899

    LON Integration with MNL series

    Hi,

    We are integrating with a Micronet MNL-100, MNL-150 and MNL-200 Series Controllers type of controller.

    However, we cannot see the NVs that describe the Input/Output state(s) of the...
  2. Replies
    9
    Views
    1,751

    Thanks for responses. We can try to increase the...

    Thanks for responses.
    We can try to increase the econo setpoint, but I do believe that the diffusers' throw will need to be looked at as well.
  3. Replies
    9
    Views
    1,751

    Yes, the unit incorporates a full economizer...

    Yes, the unit incorporates a full economizer system, AND yes, you hit the nail right on the head: by dumping I mean the air feels cold when not actively heating and the outdoor air is cold.
  4. Replies
    9
    Views
    1,751

    How do I avoid cold-air dumping?

    Hi,
    I have a 2 Stage Htg/Clg Unit at a restaurant controlled by a ddc controller c/w space sensor.

    The issue is that the occupants/clients can feel the air being dumped on them when the space...
  5. Replies
    4
    Views
    1,051

    Liebert Common Alarm Connection

    Hey Hey,

    I am using an ALC ZN141+ to monitor the 'Common Alarm Dry Contact' on a Liebert Mini-Mate 2 AC unit.

    Some time during the day/night, the associated Wall mounted thermostat (c/w unit)...
  6. Replies
    11
    Views
    1,275

    You are right Dog...this was an existing JACE...

    You are right Dog...this was an existing JACE installation and the router was added after the fact.

    From the Net Mgmt Tools perspective, the network is fine. It can see and talk to all the...
  7. Replies
    11
    Views
    1,275

    Thanks Dog. It is an Echelon 78kbps-to-78kps...

    Thanks Dog.
    It is an Echelon 78kbps-to-78kps (FTT10A to FTT10A) router...
  8. Replies
    11
    Views
    1,275

    I found out a little more about the application....

    I found out a little more about the application.

    The LON router was added and configured using a different LonWorks Network Mgmt tool: Circon Network Integrator.

    The JACE Device is based on...
  9. Replies
    11
    Views
    1,275

    The LON router was added using the network...

    The LON router was added using the network managment tool. The near side subnet/node id is 1/144, and the far side subnet/node id is 6/1.

    From the network management tools perspective, all the...
  10. Replies
    11
    Views
    1,275

    Doesn't the FX60 need to 'discover' the router...

    Doesn't the FX60 need to 'discover' the router somehow?
  11. Replies
    11
    Views
    1,275

    How to add a LON router to FX60...

    I added a LON router to my network, and configured it using LonMaker for Windows...how do I get the FX60 to recognize the LON router to my network of devices?
  12. Replies
    8
    Views
    765

    Thanks for the replies... I am trying to get...

    Thanks for the replies...

    I am trying to get around having to purchase software for programming the FX60. Sounds like I am better off buying the Workbench (Pro) to program the FX60...Bummer.

    I...
  13. Replies
    8
    Views
    765

    FX60 Requirements...

    I am thinking of using an FX60 on a future project, however, I am unclear as to wether it requires the FX Workbench to program it, OR if it comes with...
    Anybody know if the FX60 can be purchase...
  14. Replies
    15
    Views
    2,491

    Ralson Metals make some decent panels, and the...

    Ralson Metals make some decent panels, and the price is right...

    http://www.ralstonmetal.com/
  15. Replies
    6
    Views
    866

    ...I wonder how the PROs would approach it.

    ...I wonder how the PROs would approach it.
  16. Replies
    6
    Views
    866

    AC requirements to Home Addition

    Okay, a friend has built an addition to his home...a 24' x 30' family room area.

    The temptation is to simply tee off the existing duct work from the existing house, and extending it to two...
  17. Replies
    1
    Views
    532

    if (uiInput = ST_OFF) then //Universal input...

    if (uiInput = ST_OFF) then //Universal input cfg as SNVT_lev_disc.
    tmrDelay = 30 //Delay on make set for 30 seconds
    end if
    if (tmrDelay = 0) then
    uoOutput = ST_ON //Universal...
  18. Replies
    8
    Views
    1,474

    sysint(yfw) ...so, a bunch of LON devices...

    sysint(yfw)
    ...so, a bunch of LON devices hanging off of twisted-pair/78kpbs FTT10A channel connects to an iLON (tp-to-ethernet router of some sort)...that then connects to a wireless...
  19. Replies
    8
    Views
    1,474

    Much obliged for the infor LonBoy.... ...

    Much obliged for the infor LonBoy....

    ...sysint...Have you used a LONWORK RF Router before?...Just need a way of going from a mini-Lon Subnet...to another mini-Lon subnet...don't want to create a...
  20. Replies
    8
    Views
    1,474

    ...nothin' eh? ..thanks for the views...

    ...nothin' eh?

    ..thanks for the views anyway...

    Dude out.
  21. Replies
    10
    Views
    1,170

    I have interfaced with Nortec humidifiers and I...

    I have interfaced with Nortec humidifiers and I do recall an analog input (0-10vdc) was required to simulate how dry/wet the air was (space, air in duct, etc...).

    I seem to recall a binary input...
  22. Replies
    19
    Views
    1,931

    All the various comp'nies have various...

    All the various comp'nies have various technical/introductory info on their VSDs.

    You can check out:

    (Siemens) http://www.sea.siemens.com/step/default.html

    or

    (Danfoss)...
  23. Replies
    8
    Views
    1,474

    LonWorks RF Routers?

    Dude here,

    Anybody ever use/have experience using RF routers between two LonWorks?

    1) What manufacturer did you try?

    2) Did it work?

    Thanks.
    Dude out.
  24. Replies
    8
    Views
    1,177

    My knowledge of radiant panels is minimal...but...

    My knowledge of radiant panels is minimal...but why would you want to use three-speed pumps?
    Are you thinking of useing 3-speed pumps on just the radiant circuits?
  25. Replies
    3
    Views
    723

    Excellent. Thankew

    Excellent. Thankew
  26. Replies
    3
    Views
    723

    Proving Exhaust Fan Air Flow

    Thinking about using a differential pressure switch (like the JCI P32 device)...and connecting the low pressure port to the inside of the exhaust duct, and leave the high pressure port open.
    This...
  27. Replies
    17
    Views
    4,249

    Meriam-Webster def'n: Main Entry: trans·duc·er...

    Meriam-Webster def'n:

    Main Entry: trans·duc·er
    Pronunciation: \-ˈdü-sər, -ˈdyü-\
    Function: noun
    Date: 1924
    : a device that is actuated by power from one system and supplies power usually...
  28. Replies
    15
    Views
    1,698

    FX40...or Tridium question!!

    Dude here,

    I have recently installed an FX40 (= Tridium Jace box) on a a LonWorks network, and will covert the LON data to BACNET side.

    The problem I am encountering is that any network...
  29. Replies
    4
    Views
    2,386

    Yah, the other tool can see ALL the other devices...

    Yah, the other tool can see ALL the other devices including the missing one.
    The protocol is Bacnet over IP.
  30. Replies
    4
    Views
    2,386

    Yep, the Insight can see all other devices...

    Yep, the Insight can see all other devices associated with the BACnet server.
    Just seems like it skipped over one device.

    The tool being used is by Cimetrix (Bacnet client tool).
  31. Replies
    4
    Views
    2,386

    Siemens Insight s/w reading BACNET data

    Hey dudes,

    I am dealing with a Siemens Insight system (don't know much about it) that is reading BACnet data from a Bacnet server.

    The Bacnet server is essentially a gateway that gathers...
  32. Replies
    56
    Views
    7,005

    Dude here, Sysint, truly sorry to hear about...

    Dude here,

    Sysint, truly sorry to hear about this story...that must really be a sting for you and for your business (and your name).

    I am curious...do they have similar installations with the...
  33. Replies
    5
    Views
    672

    yeah, I could use a cooling tstat with cooling...

    yeah, I could use a cooling tstat with cooling setpoint...but I was wondering if there is a heating tstat out there that does the same thing but with a true heating setpoint.
  34. Replies
    5
    Views
    672

    Sorry, I have an installation with...

    Sorry,

    I have an installation with 2-position, On/Off, Spring Return, N.O. heating zone valves that use 24vac.

    Anybody know of a heating only thermostat that will fit this application?

    (ie...
  35. Replies
    5
    Views
    672

    Controlling N.O. Heating Valve

    Dude here,

    I have an installation with 2-position, On/Off, Spring Return, N.O. heating zone valves that use 24vac.

    Anybody know of a heating only thermostat that will fit this application?
    ...
  36. Replies
    12
    Views
    1,346

    http://customer.honeywell.com/TechLit/pdf/77-0000s...

    http://customer.honeywell.com/TechLit/pdf/77-0000s/77-E1100.pdf
  37. Replies
    12
    Views
    2,423

    Thanks for the replies. There is a manual freeze...

    Thanks for the replies.
    There is a manual freeze stat upstream of the coil(s). How low of a MAT setpoint can I (safely) go. I am keeping it at 55F right now, but I am tempted to bring it down to...
  38. Replies
    12
    Views
    2,423

    This is a multizone hot deck / cold deck. I do...

    This is a multizone hot deck / cold deck. I do believe the heating coil is beside the cooling coil.
    The MAT is currently being controlled to 55F. Cooling coil/loop has no glycol so am worried if...
  39. Replies
    12
    Views
    2,423

    Multizone AHU - MAT control?

    G'day,
    I have a multizone ahu serving a commercial shopping area. The oat is around -2F (c-c-c-cold).
    I have found out that the chilled water / cooling system serving the ahu's cooling coil does...
  40. Replies
    5
    Views
    871

    Thanks Jayguy. You confirmed my notions...

    Thanks Jayguy. You confirmed my notions...
  41. Replies
    5
    Views
    871

    ...the EAT is 70F, and the LAT is 93F at 688CFM. ...

    ...the EAT is 70F, and the LAT is 93F at 688CFM.
    If I switch the fan to medium speed (ie 483CFM), will the space not get hotter faster?
  42. Replies
    5
    Views
    871

    Dude here, Fan coil unit with hot water...

    Dude here,

    Fan coil unit with hot water heating coil (capacity of 29,000BTUH with fan at high speed (688CFM)). Water flow through coil is 1.65GPM (EWT=165F, LWT=102F).

    What happens if the fan...
  43. Replies
    27
    Views
    2,725

    Dude here, I have heard of the rule of thumb...

    Dude here,

    I have heard of the rule of thumb "400CFM / ton of cooling".

    Is there a similar rule of thumb that uses SQ FT per ton (or CU FT per ton of cooling")?
  44. Replies
    2
    Views
    615

    Dude here.... I have a domestic hot water...

    Dude here....

    I have a domestic hot water recirc pump 8GPM @ 17psi (40ft.w.c.)

    I was thinking of using a flow switch to monitor the flow for a DDC system.

    However, the flow switch imposes a...
  45. Replies
    7
    Views
    1,320

    Tis all good answers. This is a job that is going...

    Tis all good answers. This is a job that is going to be installed in the next couple of months.
    I was thinking of going with a flow switch, but I need to make sure that there is enough trickle flow...
  46. Replies
    7
    Views
    1,320

    Dude here, I have a 23gpm, 20ft wc pump...

    Dude here,

    I have a 23gpm, 20ft wc pump pumping hot water into a direct return circuit with baseboards using two way valves.
    What's the best way to prevent the pump from dead heading?...
  47. Replies
    21
    Views
    2,095

    A LON device, or node has network variables....

    A LON device, or node has network variables.
    Each network variable has a SNVT (or UNVT) associated with it.

    If the static pressure network variable has a data type of "SNVT_press_p", the base...
  48. Thread: Bacnet vs Lon

    by the_dude
    Replies
    24
    Views
    2,524

    ....well put UO...well put.

    ....well put UO...well put.
  49. Thread: Pump Status

    by the_dude
    Replies
    14
    Views
    1,170

    ....that's the stuff I was looking for. ...

    ....that's the stuff I was looking for.

    Muchas Gracias Internet Amigos....
  50. Thread: Pump Status

    by the_dude
    Replies
    14
    Views
    1,170

    What no experience with Flow Switches? (paddle...

    What no experience with Flow Switches? (paddle type of flow switches?)
Results 1 to 50 of 104