Search:
Type: Posts; User: CallaDrilling
Search: Search took 0.00 seconds.
-
05-17-2013, 10:09 PM
- Replies
- 5
- Views
- 303
The downside is also the size restrictions. We...
The downside is also the size restrictions.
We typically install 1" loops for our residential homes. The header system only comes in 3/4" inlets with 1 1/4" outlets.
I was in talks with GeoSolar... -
05-16-2013, 09:58 PM
- Replies
- 5
- Views
- 303
I have never used it, but have seen one. It...
I have never used it, but have seen one.
It requires a heating iron with a smaller tip or side mount elements.
Look at the irons on pipefuser.com .. It's the kits I've bought and use still. The... -
03-04-2013, 10:59 PM
Thread: Geothermal Purge/Flush Cart
by CallaDrilling- Replies
- 10
- Views
- 1,452
We bought a b&d manufacturing as a last minute...
We bought a b&d manufacturing as a last minute resort with a 2hp pump.. We ran out of time to build one so had to purchase it ASAP.
Building one is quite easy, or you could rig some PVC together... -
02-13-2013, 07:41 PM
- Replies
- 6
- Views
- 1,356
If 5x150'/ton was sized correctly and transfer...
If 5x150'/ton was sized correctly and transfer heat efficiently, then 3x250' will not change the outcome at all!
I usually cut our bore hole count down to save time of rig setup/break down on a... -
12-21-2012, 08:25 PM
Thread: My last sheet metal project.
by CallaDrilling- Replies
- 17
- Views
- 2,282
Sorry, don't take it as offensive. LOL I just...
Sorry, don't take it as offensive. LOL
I just never seen one before, and frankly don't know why anybody would want a snow scoop?
I am from NJ where we get a fair bit of snow too, and have never... -
12-20-2012, 10:08 PM
Thread: My last sheet metal project.
by CallaDrilling- Replies
- 17
- Views
- 2,282
What is it? A sled or a shovel?
What is it?
A sled or a shovel? -
12-19-2012, 05:07 PM
Thread: Rehau double loops
by CallaDrilling- Replies
- 7
- Views
- 816
That's one of my concerns too. Seems like a great...
That's one of my concerns too. Seems like a great idea until real world scenarios get in the way (swelling clay and running sands in particular).
-
12-19-2012, 02:27 PM
Thread: Rehau double loops
by CallaDrilling- Replies
- 7
- Views
- 816
If you want to send me your thought in a PM, that...
If you want to send me your thought in a PM, that would be great. Im always curious as to others thoughts on different materials. It just seems ike a nightmare to uncoil 2 loops, clipped togethter...
-
12-18-2012, 08:03 PM
Thread: Rehau double loops
by CallaDrilling- Replies
- 7
- Views
- 816
Did you get this job? What was your personal...
Did you get this job?
What was your personal opinion after further research? -
12-01-2012, 08:55 PM
- Replies
- 43
- Views
- 7,089
Good decision. Most of the negative opinions are...
Good decision.
Most of the negative opinions are from Standard HVAC installers who have never installed or educated on geothermal!
I am a fan of geothermal, and would always go geo over gas unless... -
11-10-2012, 09:41 AM
Thread: Closed Loop Antifreeze
by CallaDrilling- Replies
- 13
- Views
- 1,755
I am hoping your referring to a poor attempt at...
I am hoping your referring to a poor attempt at "humor" and not a poor attempt at a "hummer" , cause that would just be weird. By the way, I'm not that kind of guy!
-
11-09-2012, 03:58 PM
Thread: Open Loop Problems?
by CallaDrilling- Replies
- 10
- Views
- 1,290
I glad you got fixed it. If it was a well...
I glad you got fixed it.
If it was a well issue it would have Cost more than $600 probably. -
11-08-2012, 07:59 PM
Thread: Open Loop Problems?
by CallaDrilling- Replies
- 10
- Views
- 1,290
That's good news (i guess). But you still haven't...
That's good news (i guess). But you still haven't found the problem ( the bad news).
Hopefully it's a simple fix. Possibly the Taco ( or other brand) valve on the outlet side of the geo is a good... -
11-04-2012, 06:56 PM
Thread: Closed Loop Antifreeze
by CallaDrilling- Replies
- 13
- Views
- 1,755
Congrats on the self install! Although specialty...
Congrats on the self install!
Although specialty tools are not required, they sure do aid in the process of simplifying the install. Fusion joints require a certification process, but are less... -
11-01-2012, 01:05 PM
Thread: Open Loop Problems?
by CallaDrilling- Replies
- 10
- Views
- 1,290
They seem correct to me for a wx-302. Put even...
They seem correct to me for a wx-302.
Put even so, It still seems to sound like a well that is not producing like it may have in the past.
Your tank is not always FILLED. Some the pump will kick on... -
10-31-2012, 09:37 PM
Thread: Plumbers......
by CallaDrilling- Replies
- 22
- Views
- 3,114
judging from the old school water softner in the...
judging from the old school water softner in the back ground and the second line capped off right next to it. it was either relocated, or that was the old location for the water heater.
-
10-31-2012, 03:21 PM
- Replies
- 9
- Views
- 971
www.climatemaster.com www.waterfurnace.com...
www.climatemaster.com
www.waterfurnace.com
they both have caluclators on there sites. -
10-28-2012, 10:33 AM
Thread: Open Loop Problems?
by CallaDrilling- Replies
- 10
- Views
- 1,290
Well tank info.
What is the brand and model number on your well tank?
A well tank that has a drawdown of over 20 gallon in between cycles would be a huge tank for residential useage. You could have a wellxtrol... -
10-26-2012, 02:08 PM
Thread: Open Loop Problems?
by CallaDrilling- Replies
- 10
- Views
- 1,290
Hello Bob, Let me first start by saying, I am a...
Hello Bob,
Let me first start by saying, I am a Licensed well driller.
From what you mentioned about running the hose for several minutes. He may have been drawing only water from the Holding tank... -
10-21-2012, 09:11 PM
- Replies
- 32
- Views
- 6,090
-
09-11-2012, 08:13 PM
- Replies
- 1
- Views
- 872
We "shore" do like geothermal drilling.
Here is a short video us drilling our second of three boreholes for a remodel job on the Jersey Shore.
http://www.youtube.com/watch?v=nRQLf1J59sQ&feature=youtube_gdata_player -
09-03-2012, 08:02 AM
Thread: New Guests going Pro?
by CallaDrilling- Replies
- 1,179
- Views
- 114,478
Sticky: I currently have no abilities to private message.
I currently have no abilities to private message.
-
09-02-2012, 09:12 PM
Thread: New Guests going Pro?
by CallaDrilling- Replies
- 1,179
- Views
- 114,478
Sticky: I have been looking for a way to get in contact...
I have been looking for a way to get in contact with Site moderator "dad". I was asked to contact him about my situation with Pro Membership acceptance. How can I go about contacting him?
-
08-30-2012, 04:22 PM
Thread: Calling all pro members
by CallaDrilling- Replies
- 16
- Views
- 2,599
Thanks for the Help guys. I am not going to beg...
Thanks for the Help guys. I am not going to beg and plead my case to gain access into a "secret society"! I sent in my crude trials, voiced my opinion that loop contractors are very much needed in...
-
08-29-2012, 10:14 PM
Thread: Calling all pro members
by CallaDrilling- Replies
- 16
- Views
- 2,599
I got the same generic decline letter as...
I got the same generic decline letter as Waterpirate.
Although I do not claim to be a HVAC professional, but my geothermal drilling, and loopfield knowledge is not needed here in the eyes of the...
Results 1 to 25 of 49