Search:

Type: Posts; User: TamarHV

Page 1 of 3 1 2 3

Search: Search took 0.00 seconds.

  1. Replies
    28
    Views
    1,528

    First question: Why do you want to upsize the...

    First question:

    Why do you want to upsize the unit? Simply because the other people did it?
    If that unit was put there and sized correctly then you shouldn't have to upsize period.
    Run a load...
  2. Replies
    2
    Views
    403

    All this thing is, is a glorified flare fitting,...

    All this thing is, is a glorified flare fitting, sure they work well when installed properly.
    I could see a few applications where this would come in handy.
  3. Replies
    19
    Views
    1,092

    You are right, although in terms of hurting the...

    You are right, although in terms of hurting the atmosphere, the amount of refrigerant we are talking about is minute.. , don't leave refrigerant in your hoses, or anything that holds significant...
  4. The relative humidity is important whether it's...

    The relative humidity is important whether it's occupied or not due to the equipment in the room.

    The batteries are not hydrogen venting.

    I've already figured the load of the batteries into...
  5. Replies
    13
    Views
    569

    No they won't cause a problem if you rip out the...

    No they won't cause a problem if you rip out the other junk thats there and wire it right. It is a start cap/overload/relay all in one, hence the name 3 in 1 if you already have the 3-n-1 (which is...
  6. As I stated before im not sure what exactly what...

    As I stated before im not sure what exactly what its calleD, I checked the specs and ran the load accordingly, it puts out 18,000btus @ 100% which it runs close to 100% most of the time.. That is...
  7. It is a tough situation to be in. But I want to...

    It is a tough situation to be in. But I want to make the best out of the situation. I wont be able to use a split, the fujitsu unit is pretty much set in stone. Not sure about the air-change. I don't...
  8. There is no specific humidity level that needs to...

    There is no specific humidity level that needs to be achieved. But for the sake of argument I would like to see it maintained from anywhere between 30-60% respectively, When I went inside the room...
  9. [B]Installing a 36,000 BTU Fujitsu in a Computer room, have a few questions.[/B]

    Hello gentlemen, and I use that term lightly, (kidding.)

    I was selected for the job of correcting some issues at the computer center at my local college.
    A little information on the room:

    This...
  10. Replies
    11
    Views
    728

    I did. "I took it back and they switched it."

    I did. "I took it back and they switched it."
  11. Replies
    40
    Views
    2,107

    [edit] just realized you had posted that you...

    [edit] just realized you had posted that you found a kink in the lineset, congrats on finding the problem. a kinked suction line will most definitely cause liquid to go back to that compressor, I...
  12. Replies
    17
    Views
    1,030

    A good tech will measure the static pressure of...

    A good tech will measure the static pressure of the duct and set the blower accordingly, but for all purposes, around 400 cfm is the standard per ton, but you can still be around 350-450 with...
  13. Replies
    11
    Views
    728

    just to update and clarify everyone. they gave me...

    just to update and clarify everyone. they gave me the wrong air-handler, I took it back and they switched it.
    I knew that something wasn't right because i've never installed a system with a larger...
  14. Replies
    11
    Views
    728

    ah FEM4P3600AT cond:N4A336AKB thats what the...

    ah FEM4P3600AT
    cond:N4A336AKB

    thats what the invoice says.. I need to go back and look at what the actual UNIT says.
    because I could have swore it was like FEM4P3000AT, maybe I was wrong. I'm...
  15. Best bet is going to be to try to find a case...

    Best bet is going to be to try to find a case coil that is close to the dimensions of the old one, chances are you wont be able to find the same one.

    Good luck.

    Tamar
  16. Replies
    15
    Views
    862

    I personally take my subcool/superheat right at...

    I personally take my subcool/superheat right at the condenser right by the service valves. I don't like the TYPE-K resistor type temperature clamps/probes that fluke uses so I use a COOPER thermistor...
  17. Replies
    28
    Views
    1,978

    I have to agree with the others, I don't believe...

    I have to agree with the others, I don't believe you have an electrical problem, your issue is with something inside of the system damaging the compressor. Flush the lines and REMOVE the metering...
  18. Thread: No Superheat

    by TamarHV
    Replies
    57
    Views
    4,291

    well is it an upflow or horizontal in the attic?...

    well is it an upflow or horizontal in the attic? if its a horizontal check the ductwork because there may be significant return leaks causing the coil to warm up. which all goes back to airflow.
  19. Replies
    11
    Views
    728

    3 ton condesner with 2.5 ton air handler.

    I am installing a Day & Night (basically the same thing as a bryant/carrier.) matched system on a Good customer of mine's house, I asked the guy @ Johnstone for a slimmer version of the air-handler,...
  20. Replies
    19
    Views
    2,172

    Where I'm working.. and what I got told

    So today I come to work and apparently I had a call back because there was a drain filled with orange vomit looking thick slime. Well I cleared the drain checked operations and it was fine. Well...
  21. Replies
    14
    Views
    1,775

    yeah 10-4. I'm glad I documented it, and even...

    yeah 10-4. I'm glad I documented it, and even TOLD him that same day. That;s also why I prefer the actual customer to be there when i'm there as well :/
  22. Replies
    14
    Views
    1,775

    Drain pan cracked.

    So i'm on call this weekend. And I get a call on my pager and the answering service tells me that he will not give an address, that we created a catastrophe in his house and it was flooding. Well,...
  23. Haha if you're talking about the disconnect it...

    Haha if you're talking about the disconnect it runs through a wooden fence and then back up a brick wall on the other side of the fence.
  24. What a Turd Polishing (Tune up) should look like.

    BEFORE:
    http://i50.tinypic.com/5jsm8i.jpg
    http://i46.tinypic.com/2rfghvo.jpg
    http://i49.tinypic.com/x5qijr.jpg

    AFTER
    http://i46.tinypic.com/2dh915d.jpg
    http://i47.tinypic.com/29vgbnk.jpg
    ...
  25. Replies
    19
    Views
    2,212

    LOL SWIM JUST CALLED HIM AND SAID: SWIM: Hello?...

    LOL SWIM JUST CALLED HIM AND SAID:
    SWIM: Hello?
    GUYS SON: Hello?
    SWIM: This is Jerry's Gun shop, wondering if you need any new guns to take care of future AC REPAIR men, we have the finest...
  26. Replies
    19
    Views
    2,212

    Glad my company allows us to carry. as long as we...

    Glad my company allows us to carry. as long as we got the permits to do it
  27. Replies
    95
    Views
    5,450

    maybe you're getting the wrong idea? I simply...

    maybe you're getting the wrong idea?
    I simply stated GOD is in control. Resistance to GOD is futile of course, and God chastens and reproves those who he loves. Perhaps this is Americas Judgement,...
  28. Replies
    95
    Views
    5,450

    no one can bypass god. God planned everything...

    no one can bypass god. God planned everything that will happen, even obama
  29. Replies
    95
    Views
    5,450

    YHWH is in control. Obama is just a stepping...

    YHWH is in control. Obama is just a stepping stone for the master plan
  30. Thread: masons

    by TamarHV
    Replies
    310
    Views
    25,012

    What about worshipping baphomet and lucifer?...

    What about worshipping baphomet and lucifer? Err.. all I can say to christians is you BETTER do some research before joining the masons.
  31. Poll: I dont blame you. I don't celebrate the Goddess...

    I dont blame you. I don't celebrate the Goddess Ishtar, nor Nimrod either :)
  32. Replies
    95
    Views
    5,450

    This thread needs to be revived.

    This thread needs to be revived.
  33. Replies
    32
    Views
    3,236

    Thank you very much for the replies. I appreciate...

    Thank you very much for the replies. I appreciate all of the responses. In my opinion it was a stupid thing to do, and i'd rather take the advice of the people who make 410A. Even if it only changes...
  34. Replies
    32
    Views
    3,236

    R410 Being a blend.

    I've always heard that if someone opens a drum of 410a letting vapor out, the mixture is ruined.. I was on a job and walked out to my van to find a tech blowing out a filter with one of MY drums of...
  35. Replies
    5
    Views
    937

    Doesn't really matter too much about the recip.....

    Doesn't really matter too much about the recip.. There is a reason why trane (american standard) still manufactures their own compressors, unlike carrier, and other companies who use copelands, and...
  36. Replies
    8
    Views
    1,739

    zap

    zap
  37. Replies
    5
    Views
    651

    Fence the dogs, or the unit in, keep the two...

    Fence the dogs, or the unit in, keep the two seperated and learn from it. You cant put the fins back in place. But you can try to stop them from further damaging it. Went on a call today with a...
  38. Replies
    5
    Views
    937

    My friend used to work for Carrier and said the...

    My friend used to work for Carrier and said the reason their coils leaked alot is because they had them made in mexico, and they mixed other metals in with the copper. Not that other companies...
  39. Replies
    25
    Views
    2,579

    Looks like you need to keep looking.

    Looks like you need to keep looking.
  40. Replies
    5
    Views
    571

    what he said.

    what he said.
  41. Thread: Little Peeved

    by TamarHV
    Replies
    2
    Views
    585

    probably but it is tech to tech chat, and yeah...

    probably but it is tech to tech chat, and yeah that does seem like BS to me too. I'm not sure of the legality, but if they have a hvac contractors license, even if they are a distributor,...
  42. Replies
    7
    Views
    831

    Definately need to charge by subcooling. Did you...

    Definately need to charge by subcooling. Did you verify all airflow issues? Fan speed, dirty coils.. etc. Also did you verify the TXV bulb position? needs to be 10 or 2 o clock on the suction line...
  43. Replies
    71
    Views
    5,523

    I just checked this thread again. I don't blame...

    I just checked this thread again. I don't blame you at all dude, they could have at least picked the **** up.
  44. Replies
    15
    Views
    1,483

    It has to do with a whole lot of things if it was...

    It has to do with a whole lot of things if it was working and then the compressor isn't working. comp failures aren't limited to just electrical failures. I didn't ask him for sh or sc If you read...
  45. Replies
    29
    Views
    2,988

    -rubs his head and closes his eyes like crazy a...

    -rubs his head and closes his eyes like crazy a monk guy-
    Guy I am having a sensation, yes.. I am predicting that in the near future.
    The price of 22 will rise... Argh... ;)
  46. Replies
    15
    Views
    1,483

    I'm going to assume this compressor isn't running...

    I'm going to assume this compressor isn't running so I won't ask you for SH AND SC values.. Smoke appeared at the breaker or at the compressor? Did you test the compressor to ground. Does the unit...
  47. All I can say is stop using that junk then man,...

    All I can say is stop using that junk then man, if you've been doing this for 18 years and just started having problems after using r290 then obviously 290 is the problem. And refrigerant can also...
  48. Thread: Inverted loops

    by TamarHV
    Replies
    7
    Views
    829

    That's wonderful.. But you know we win in the end...

    That's wonderful.. But you know we win in the end right?
  49. didn't know if you knew. most blended...

    didn't know if you knew. most blended refrigerants have to be charged as a liquid (whether it's a new install, a service call, a top off, you name it.- If you are installing compressors, and not an...
  50. Well.. are you charging with liquid?

    Well.. are you charging with liquid?