  1. The first two proposals are piped wrong for the...

    The first two proposals are piped wrong for the kitchen, because their both on he outlet side of the pump.

    Just have them install a automatic bypass on the pump, get rid of the HX for the kitchen...
  2. That would be cooling. Not heating. 315 is for...

    That would be cooling. Not heating. 315 is for heating.
  3. Replies
    7
    Views
    168

    That is one freaking nasty system, that has been...

    That is one freaking nasty system, that has been leaking for a long period of time.

    Is there a trap between the unit and the open T?
  4. Replies
    7
    Views
    168

    Take a picture. There needs to be a trap between...

    Take a picture. There needs to be a trap between the open T and the air handler, otherwise it won't drain correctly.
  5. What setting did you change?

    What setting did you change?
  6. Sure. But you won't be comfortable.

    Sure. But you won't be comfortable.
  7. Your probably adjusted your oil heat CPH instead...

    Your probably adjusted your oil heat CPH instead of your heat pump.


    Seriously, Leave it be. Those numbers sound great.
  8. Thats because they are cavitating the pumps....

    Thats because they are cavitating the pumps. You've got a pump that is practically dead heading when only 1 zone opens.
    You MUST have a bypass.
    The other problem is that your going to kill the...
  9. What is the red box where the kitchen loop...

    What is the red box where the kitchen loop connects to the rest of the system? Is that a heat exchanger?

    What turns off each zone of baseboard? Zone valves?
    Can each individual zone turn on the...
  10. engineer.

    engineer.
  11. Replies
    30
    Views
    2,476

    Whats really crazy, is thats a copper coil....

    Whats really crazy, is thats a copper coil. Meaning it's atleast 4 years old XD
  12. WOAH. I never even thought of that. *mind blown*...

    WOAH. I never even thought of that. *mind blown*

    I should probably paint it though. How'd you get it in there, multiple pieces?
  13. Replies
    37
    Views
    678

    I wouldn't worry about it.

    I wouldn't worry about it.
  14. Replies
    37
    Views
    678

    It's not unusual for those jackels running on...

    It's not unusual for those jackels running on goodmans to run pretty warm. So, I agree with the others.
  15. Replies
    10
    Views
    579

    Amp out the ignitor. See if it reaches a peak...

    Amp out the ignitor. See if it reaches a peak before the gas comes on.

    Try it cold (allow 10 minutes of rest before trying). If the ignitor doesn't peak prior to gas, replace.
  16. He should absolutely add a secondary pan. The...

    He should absolutely add a secondary pan. The sensor will only help if the drain blocks up.

    What if the coil freezes? What if the pan cracks?
    If one of those 2 happen, you will have water damage.
  17. Replies
    8
    Views
    777

    Lol. Anyone else notice the control board of the...

    Lol. Anyone else notice the control board of the EAC?

    Thats a mighty big furnace too.
  18. Replies
    9
    Views
    941

    He's joking about them making the line smaller. ...

    He's joking about them making the line smaller.
    Looks like a 3/8 liquid line, and they attached it to a peice of 1/4 they had laying around.
    Or a 1/4 liquid line, that would act like a restriction.
  19. Replies
    16
    Views
    898

    Maybe. Just to be clear, I was being jovial...

    Maybe.


    Just to be clear, I was being jovial about the plugs. I've never seen a gas motor with glow plugs.
  20. I'm strictly an Amana/Goodman guy, so I can't...

    I'm strictly an Amana/Goodman guy, so I can't give you an answer on other mfgs.

    Weird question:
    What do you feel your actually missing by not having the communicating thermostat?
    It's really not...
  21. Looks little different to me. Those munchkins are...

    Looks little different to me. Those munchkins are freaking trash, so if it is the same, your diff better off getting rid of it.
  22. Replies
    19
    Views
    721

    ...what drain plugs? Post the model number. ...

    ...what drain plugs?
    Post the model number.

    Post a picture of the rot.

    If this tech is rough, i would fine someone else.
  23. Replies
    16
    Views
    898

    Glow plugs, and its not a diesel.

    Glow plugs, and its not a diesel.
  24. It will still ramp without the communicating...

    It will still ramp without the communicating stat. The board talks to the motor. The stat talks to the board. The stat doesnt control actual airflow.

    The majorityof ourinstalls are actually in...
  25. Replies
    16
    Views
    898

    "Communicating wire" is very vague. Is it a...

    "Communicating wire" is very vague. Is it a communicating system? Is it a standard 24v system? I have no idea, and can't help you without more information.
    What kind of system is this?

    AGAIN,...