  1. Replies
    12
    Views
    431

    Think you might have something there. Need to...

    Think you might have something there. Need to install a pressure gauge after filter. Unit is water cooled and gets its water from the filter. Just a large carbon filter. Seems to fit my symptoms.
  2. Replies
    12
    Views
    431

    Did not check pressures. Due to good ice...

    Did not check pressures. Due to good ice formation. Could it be low on Freon. Might go ahead and weigh in a charge. I am not the first to work on this machine.
  3. Replies
    12
    Views
    431

    Ice bridge could be a little thicker. For my...

    Ice bridge could be a little thicker. For my taste.
  4. Replies
    12
    Views
    431

    Dump valve is closing with no leakage.

    Dump valve is closing with no leakage.
  5. Replies
    12
    Views
    431

    Yes. It does the second fill.

    Yes. It does the second fill.
  6. Replies
    12
    Views
    431

    Manitowoc qdo603w

    Ran into a head scratcher. Checked unit. Found equipment ground not connected, unit locked out on error 2. Which is 3 consecutive harvest exceeding 3.5 min.
    Ran unit found. Sump runs dry before...
  7. Thread: Hydrobank?

    by meoberry
    Replies
    0
    Views
    209

    Hydrobank?

    Ran across a MOB with 8 of these things. The model is g360vhc made by Mammoth. Cannot get info on them. They feed vavs on each floor. They have what looks like a hot gas bypass on the first stage...
  8. Replies
    4
    Views
    549

    hoshizaki kah130

    Thought I already posted this. But can't find thread.
    Have a problem I have not ran into before. Unit occasionally freezes up. Ran for 30 days this time. Unit does not lock out. So no beebs. Will...
  9. Had one reading wrong temp. Found the insulation...

    Had one reading wrong temp. Found the insulation around the well had slipped down. Put insulation back and secured with wire tie. Sensor was OK! Temp was within 2* of my Thermometer. Was 7* off.
  10. Replies
    26
    Views
    1,431

    Yes. It will cut out on high pressure. In the...

    Yes. It will cut out on high pressure. In the heat mode. Your inside coil is the condenser and the outside is the evaporator. The unit is not designed to run much over 65* in the heat mode.
  11. Replies
    2
    Views
    1,250

    Bet that burning plastic smelled good...LOL

    Bet that burning plastic smelled good...LOL
  12. Think you nailed it. With LLS leaking.

    Think you nailed it. With LLS leaking.
  13. Replies
    483
    Views
    14,142

    Why do they call us prolife. When they do not...

    Why do they call us prolife. When they do not consider an unborn baby life.
    Why do they call a human without brainwaves or a heart beat.....dead.
    But a baby in the womb with brainwaves and a heart...
  14. Replies
    483
    Views
    14,142

    Planned parent hood. Gives away free condoms. So...

    Planned parent hood. Gives away free condoms.
    So if you choose to have sex without a condom.
    Then you have made your choice.
  15. Replies
    7
    Views
    2,120

    I am having the same issue with a cgam chiller...

    I am having the same issue with a cgam chiller less than 2 years old. It seems the sensor fails to read accurately all the time. When I would check it it was about 3 degrees off. Another tech caught...
  16. Sounds like you might have it whooped. Might...

    Sounds like you might have it whooped. Might consider a small pump like a taco circulation pump. Depends on the cost of ripping out pipe versus the pump.
  17. Replies
    20
    Views
    1,740

    No 15x30 is too small for a 3 ton. 20x20...

    No 15x30 is too small for a 3 ton. 20x20 preferable 20x30 would be adequate.
  18. Replies
    20
    Views
    1,740

    Another factor. I did not see mentioned. (unless...

    Another factor. I did not see mentioned. (unless I missed it) Is the filter media. If you are using the popular cheap throw aways you can get away with the smaller grills. If you are using the...
  19. Thread: New gages

    by meoberry
    Replies
    44
    Views
    3,535

    I just check pricing on Sman 460....ack...choke....

    I just check pricing on Sman 460....ack...choke. I think I will stick with my 360s. ( I must be getting old, close to a grand seems to be a lot to me.)
  20. Replies
    70
    Views
    11,417

    I have worked on Goodman (used to be Janitrol)...

    I have worked on Goodman (used to be Janitrol) for as far back as I have been in this business. The only thing I thought was the weak link was the second string Bristol compressors they used. I have...
  21. Replies
    9
    Views
    602

    Think it is too late. Sounds like compressor...

    Think it is too late. Sounds like compressor might have gone to ground. Me personally. I would not waste any more time or money on a 10 seer.
  22. Replies
    29
    Views
    3,093

    I agree. Sometimes an evacuation can take all...

    I agree. Sometimes an evacuation can take all day. I have left a pump on and went to another call. Some times several. Its bad enough when someone un plugs your pump, because they needed the plug. ...
  23. Hvac69 is right. Did not think about strainer....

    Hvac69 is right. Did not think about strainer. Usually check then first. I have seen everything from scale to an old rag in them (from construction).
  24. Replies
    14
    Views
    1,590

    When I went to trade school. Oh. So many years...

    When I went to trade school. Oh. So many years ago. (No I won't say how many). We had an old glass cooler. We kept or drinks and lunches in. That had been converted to 134a. Had an old belt driven...
  25. ;)Have not seen the Digicools. Have had to sets...

    ;)Have not seen the Digicools. Have had to sets of smans set of sman3 which where the first year of production. Had a lot of problems. But factory took care of me. Bought another set of the sman...
  26. I could be wrong. But it seems DuPont. Might be...

    I could be wrong. But it seems DuPont. Might be behind all these refrigerants getting banned. They always seem to have a replacement waiting, when an old one gets banned.:det:
  27. Replies
    14
    Views
    1,590

    Was told by an employee of a major A/C...

    Was told by an employee of a major A/C manufacturer that the only difference between a 410 coil and a 22 coil is the expansion device. They use the same coils.
  28. Get temp on incoming water and watch. If water...

    Get temp on incoming water and watch. If water temp goes up then there is a flow issue. Make sure your water supply and return hoses are not switched. Usually on a cooling tower system. one pipe is...
  29. Replies
    19
    Views
    2,090

    Alot of the higher Seer rating stuff is charge...

    Alot of the higher Seer rating stuff is charge critical. So you need the SH and SC to be on the money. The newer refrigeration stuff is going the same way. Receivers are getting smaller to reduce...
  30. Replies
    40
    Views
    3,414

    Lets not forget. SEER rating, Inside and outside...

    Lets not forget. SEER rating, Inside and outside air temp/ humidity also changes head pressure readings.
  31. Replies
    18
    Views
    1,311

    Very possible. Asked dealer to send me all...

    Very possible. Asked dealer to send me all expansion devices for this unit. They only sent me the TXV valve. With the burn out I had. I figured the crap had already fouled any screens or valves in...
  32. Replies
    18
    Views
    1,311

    Must be multi circuit. Did not see anything that...

    Must be multi circuit. Did not see anything that looked like cap tube and no piston. Will have to get more info from factory.
  33. Replies
    5
    Views
    3,533

    The whole time I was laughing. I kept...

    The whole time I was laughing. I kept saying....What an idiot.....He will sleep on couch for at least a week....LOL

    The best response to a question like that. IS ABSOLUTLY ......NO COMMENT...LOL
  34. I agree with superfitter. I have seen far worse....

    I agree with superfitter. I have seen far worse. I does need a good cleaning to remove the rust. The best and safest way for a home owner to check for holes in exchanger. Is to watch flames when...
  35. Replies
    18
    Views
    1,311

    Guess. I will have to dig up George Ezells number...

    Guess. I will have to dig up George Ezells number with Rheem and chew his ear.
  36. Replies
    18
    Views
    1,311

    This is what was blowing my mind.

    This is what was blowing my mind.
  37. Replies
    18
    Views
    1,311

    Yes heat only. Cool pressures where within specs

    Yes heat only. Cool pressures where within specs
  38. Replies
    18
    Views
    1,311

    It has some distributor tubes coming out to a...

    It has some distributor tubes coming out to a funny looking copper cylinder that kinda looks like a very small spun copper drier. There is no temp drop across it though.
  39. Replies
    18
    Views
    1,311

    My bad. Did I mention it was a heat pump

    My bad. Did I mention it was a heat pump
  40. Replies
    18
    Views
    1,311

    Anyone know where I can get a tubing schematic...

    Anyone know where I can get a tubing schematic for this unit?:det:
  41. Replies
    18
    Views
    1,311

    Have not worked on rheem in 6 or 7 years. This...

    Have not worked on rheem in 6 or 7 years. This thing only has one xvalve and no piston or short tube orrrifices that I can see.
  42. Replies
    18
    Views
    1,311

    No outdoor piston that I can find.

    No outdoor piston that I can find.
  43. Replies
    18
    Views
    1,311

    Rheem rqpn 5 ton

    Had a grounded compressor. Burnt Freon and burnt windings in oil. Flushed system, new compressor, new liquid drier, vacuumed and recharged. Unit started and went to a restriction. Traced back to...
  44. Thread: tam5

    by meoberry
    Replies
    6
    Views
    1,215

    Unit ran through start up cycled valve and locked...

    Unit ran through start up cycled valve and locked out. Condensing unit did not have time to start. Need to check SH sensor,
  45. Thread: tam5

    by meoberry
    Replies
    6
    Views
    1,215

    Thanks. Where can I find the service fact sheet...

    Thanks. Where can I find the service fact sheet with the diagnostic codes? Seems I just picked up a new customer that owns 6 of these units.
  46. Thread: tam5

    by meoberry
    Replies
    6
    Views
    1,215

    tam5

    I just seen my first trane tam5 air handler. After brief exam of unit. It seems a pretty unique design. Blower at bottom to create positive pressure cabinet. Neat electronic x valve controlled by 2...
  47. Thread: Arizona jobs

    by meoberry
    Replies
    5
    Views
    1,381

    Dairy. Does the term Dairy air, ring a bell....

    Dairy. Does the term Dairy air, ring a bell. Thats where the saying comes from. I have worked at several independent dairys. You will be washing digested grass out of condensor coils, you will...
  48. Replies
    23
    Views
    3,098

    I have used all types of meters. My preference is...

    I have used all types of meters. My preference is Fieldpiece. Although I do not buy the clamp styles anymore. After two of them the wires going to the clamp broke on the inside. Iprefer the sticks...
  49. Myth or fact

    I have been in this business for over 20 years and have worked for several different companies. Have had my own bussiness for a couple of years. Too much agravation for my taste. Ninety percent of...
  50. did you find freon leak? Would recommend a...

    did you find freon leak? Would recommend a nitrogen pressure check and check at outlet of condenser water. Check and see if hot gas valve is sticking. But like what was posted earlier. Manitiwoc. Do...
Results 1 to 50 of 766