    IMO when it is off and its 70 outside as you say,...

    IMO when it is off and its 70 outside as you say, you likely opened the windows and let in some fresh air AKA latent load then the system was turned on to fight the latent load > that being said have...
  2. Yes your not looking at the correct type of unit...

    Yes your not looking at the correct type of unit " if the building Source, IE ; central heating plant is supplying the hot and chilled water " what you need is as was said already a blower coil. as...
  3. Well IMO you should never set back a a\c ,set it...

    Well IMO you should never set back a a\c ,set it and forget it Say At 73' a a\c should not recover or cool fast Ever
    That being said it sure should have been set up correctly I don't know what it...
  4. Replies
    7
    Views
    353

    Ok so in the event of a leak what would happen it...

    Ok so in the event of a leak what would happen it fills said pan then overflows ? onto the floor ? see the pan is a safety device generally to protect something IE a ceiling ,a floor or what have...
  5. Replies
    7
    Views
    353

    Ok then that isn't acidic though the rust...

    Ok then that isn't acidic though the rust inhibitor paint should help out its likely due to the dampness in the crawlspace also could replace with a plastic or fiberglass pan although the real...
  6. Replies
    7
    Views
    353

    Was the drain from the furnace or a\c if from the...

    Was the drain from the furnace or a\c if from the furnace it contains acid and that may have been the cause of rust ? you could paint the pan with like rust- olium or the like first it will need to...
  7. Replies
    4
    Views
    292

    KEEP looking for someone to do a man-j its your...

    KEEP looking for someone to do a man-j its your money and comfort at stake! IMO all 3 are oversized and if they don't want to do the first step what else don't they want to do (a good job)
  8. Replies
    46
    Views
    1,190

    Your missing the point, I say you wont save $10...

    Your missing the point, I say you wont save $10 or any $ at all, especially if you oversize. Set the stat at 74' or whatever your comfortable and leave it alone until fall when its time for heat then...
  9. Replies
    46
    Views
    1,190

    YES that's what we are saying "sized properly"...

    YES that's what we are saying "sized properly" the fudge is in there, and set back are not a real $ saver
  10. Replies
    6
    Views
    282

    Do your homework "Son"(no offence intended) Put...

    Do your homework "Son"(no offence intended) Put the time in Now instead of after the Problem "install"! Get many quotes with references , pictures and speak to other costumers of theirs. Then...
  11. Replies
    46
    Views
    1,190

    No it should never be over - sized stop the...

    No it should never be over - sized stop the setbacks their a lot of hype not a lot of savings
  12. NO don't ever do that NO NO NO

    NO don't ever do that NO NO NO
  13. This is why the code is in place "unit \...

    This is why the code is in place "unit \ equipment shall not be used during construction" which is also part of most if not all mfg. instructions and warranty disclaimers thus a "construction heater...
  14. Replies
    5
    Views
    339

    Well the bets are in, I'm also all for two...

    Well the bets are in, I'm also all for two systems,over one zoning system anytime and every-time for the afore mentioned reasons and a slough of others. Two systems = Happy, Happy, Happy
  15. Replies
    10
    Views
    505

    a roll - out shouldn't or wouldn't be caused or...

    a roll - out shouldn't or wouldn't be caused or be cured by gas pressure you have other dangerous conditions yes lowering the flame will bring it into the fire box though it surely isn't fixing the...
  16. Replies
    10
    Views
    505

    wow get a pro out soon ! Id turn it off until...

    wow get a pro out soon ! Id turn it off until they get there! you could have a bomb waiting to go off !!! soot is a sign of improper combustion and adjusting gas pressure could aggravate the issue
  17. Replies
    15
    Views
    934

    wow that's some story and yet so common keep your...

    wow that's some story and yet so common keep your head and remain firm after all its your comfort at stake
    that's some great info dan sw fl THANKS for sharing
  18. Replies
    39
    Views
    2,590

    Ah yes ?? why indeed , and why would he not want...

    Ah yes ?? why indeed , and why would he not want a accurate load calc. himself if you can come here and get it
  19. Replies
    39
    Views
    2,590

    insist on man.J its your money and comfort at...

    insist on man.J its your money and comfort at stake other wise its a guess ... would you spend money with other guessers ?
  20. Replies
    7
    Views
    496

    IMO you'll have far better control the way it is...

    IMO you'll have far better control the way it is and it wont cost a thing to leave it as is
    are they 1st and 2nd floor separations? You will likely want to move the hamper it looks to be melting?...
  21. Generally the factory warrants parts and the...

    Generally the factory warrants parts and the installing contractor provides the labor warranty, though in some instances there's a nominal kick from the mfg. also IMO third party warranties are shaky...
  22. Replies
    8
    Views
    528

    wow, you only have piss poor contractors in your...

    wow, you only have piss poor contractors in your area ? where do you live?
  23. Replies
    23
    Views
    1,212

    miss calculated , miss diagnosed, why not replace...

    miss calculated , miss diagnosed, why not replace parts until it works?$$$
  24. the valves should be 30# no more!! call a...

    the valves should be 30# no more!! call a different pro and get it looked at soon, as this continued fresh feed is not good for the system
  25. to that it should be under 5% although every...

    to that it should be under 5% although every thing else also would get bigger