Search:

Type: Posts; User: apprentice3

Page 1 of 20 1 2 3 4

Search: Search took 0.02 seconds.

  1. Replies
    23
    Views
    2,166

    I was at some type of country club at the time....

    I was at some type of country club at the time. Nothing came out of it though. New ownership but still don't pay their bills.
  2. Replies
    20
    Views
    707

    Thanks for the reply. I will check on the...

    Thanks for the reply. I will check on the driver. I know I have a mixture of the 2013 and 2010 stuff. The system I am having most of the problems with is the linkage zone control system. The RTU,...
  3. Replies
    20
    Views
    707

    Also on a side note I was looking at the control...

    Also on a side note I was looking at the control programs loaded into each of the controllers. Most of them are vvt_zn_iv6-3_06_20131017. Which two of these controllers are having issues. I have...
  4. Replies
    20
    Views
    707

    I replaced the network wiring as necessary and...

    I replaced the network wiring as necessary and installed the necessary termination modules on the system. After a few days the customer was still complaining about losing communication with the...
  5. Thanks for the reply! So if I am adding new...

    Thanks for the reply!

    So if I am adding new VAV controllers to a existing CCP can I do it through the Summit work station on site or do I need to do it at the CCP itself? If I have to do it at...
  6. Also it has been awhile since I connected to CCP....

    Also it has been awhile since I connected to CCP. Hyper terminal will work on this right?

    Thanks!
  7. Trane CCP + VariTrac VAVs into Tracer Summit

    Here in about a week or so I have to pull some additional VariTrac VAV controllers into Tracer Summit. I have installed and pulled in a lot of different controllers into Summit including these...
  8. Replies
    20
    Views
    707

    I am not sure. I know it isn't Carrier though. ...

    I am not sure. I know it isn't Carrier though. The thermostats look identical to the Carrier and ALC stats. Plus you can plug into them with BACset. So I was just curious.

    Also I have another...
  9. Replies
    20
    Views
    707

    Do you know if this field assistant will work on...

    Do you know if this field assistant will work on other devices that you can connect to with BACset? Like for instance I have some Florida Heat Pumps with BACnet interfaces that are configured...
  10. Replies
    20
    Views
    707

    Also I acquired some of the I-Vu tools awhile ago...

    Also I acquired some of the I-Vu tools awhile ago while I was working on another job site that had a disc laying around, but my I-Vu tools seem to be incomplete. I don't have the BACview or Field...
  11. Replies
    20
    Views
    707

    I got with my rep on this update today. He told...

    I got with my rep on this update today. He told me that this driver update is for USB to CCN communications. I have a open system. Does this update apply to BACnet too?

    Thanks for all of the...
  12. Replies
    20
    Views
    707

    Yes it is 6.0. Someone at Carrier sent me some of...

    Yes it is 6.0. Someone at Carrier sent me some of the latest updates today. How do I load them into the IVU? Plug a flash drive into the black box?

    Thanks for the reply!
  13. Replies
    20
    Views
    707

    Carrier I-Vu Open Question

    I was working on a Carrier I-Vu system today with tons of network problems. I had a few questions regarding network design.

    All of the documentation that I have on network design mentions a...
  14. Replies
    3
    Views
    183

    Thanks! If anyone else has anymore information...

    Thanks!

    If anyone else has anymore information please send it my way.
  15. Replies
    2
    Views
    152

    You could create a account on MyTraneControls and...

    You could create a account on MyTraneControls and download the latest service pack for free or run it directly from the site. I don't have a copy of it, but I just ran it from the website itself at...
  16. Replies
    0
    Views
    110

    Tracer 100 Modem

    Would anyone be able to send me a link to a modem that will work on a Tracer 100 system? I seem to recall seeing a modem from U.S. Robotics on a job before, but I cannot remember if there was...
  17. Replies
    3
    Views
    183

    Parker/Carrier VVT Generation 2

    Does someone have a copy of the manual for the old Carrier VVT Generation 2 system? I seem to recall there being some sort of blue book for this system that had a lot of information. If anyone has...
  18. Replies
    9
    Views
    295

    Thanks for the reply. So what do the email...

    Thanks for the reply.

    So what do the email alerts look like when they come through? For example if I set up a email alarm class and put it on my chillers critical alarm tab will it tell me over...
  19. Replies
    9
    Views
    295

    Tracer Summit V17 SP13 Email Alerts

    I see there is some reference to setting up a email address in Tracer Summit on the newer versions.

    I was wondering what can be done with this?

    I have a customer who is asking me if Tracer...
  20. Replies
    9
    Views
    296

    I do know that the flow pick ups and damper...

    I do know that the flow pick ups and damper assemblies on these VAVs are brand new. I haven't checked the pressure differential yet. I will do that on my next visit. I did try putting a 0 pressure...
  21. Replies
    9
    Views
    296

    I have never had to reload the resource files in...

    I have never had to reload the resource files in Tridium before. Would I be able to just delete the entire controller, pull a clean one out of my LonHoneywellWizard Palette, and match? I can maybe...
  22. Replies
    9
    Views
    296

    Yeah at first that is what I thought it was. I...

    Yeah at first that is what I thought it was. I verified that it is configured for pressure independent. When I switch the configuration to pressure dependent the airflow setpoints go away...
  23. Replies
    9
    Views
    296

    Honeywell XL10 - nvoBoxFlow = NAN

    I was working on a Honeywell Lon Integration the other day and while I was going through commissioning I noticed that one of the VAV boxes was showing NAN for the nvoBoxFlow. The VAV Box Damper and...
  24. I tried to create a new area and set my security...

    I tried to create a new area and set my security to full access but the TOV is still grayed out. It wasn't like this until the upgrade. These controllers are just the standard comm 4 UCM III/IV VAV...
  25. Replies
    1
    Views
    230

    Tracer SC VAS Setup Questions

    I have a job with a Trane Intellipak serving about 34 VAV Boxes. We have been having some problems with the unit tripping off on high SA static pressure alarms. It seems to happen whenever the unit...